ECB violations
1516-1520 Sedgwick Avenue, Bronx • Block 02880 • Lot 0017
54 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 8, 2026 | 39552761N | ACTIVE | CLASS - 2 | OBSERVED AT EXPOSURE 2 (GARAGE DOOR AT ADJACENT PROPERTY) AND EXPOSURE 4 (PARKING LOT GATE), SIDEWALK SHED POSTS LACK... | $2,400 | $2,400 | Dec 4, 2026 |
| Feb 9, 2026 | 39176517P | ACTIVE | CLASS - 2 | THE PHONE IS NOT WORKING | $625 | $625 | Aug 28, 2026 |
| Jan 22, 2025 | 39536175K | RESOLVE | CLASS - 2 | AT TIME OF MY INSPECTION I OBSERVED A SIDEWALK SHED AT A 16 STORY OCCUPIED BUILDING.SIDEWALK SHED IS MISSING INFORMAT... | $1,250 | $0 | Dec 19, 2025 |
| Jan 22, 2025 | 39536174Z | RESOLVE | CLASS - 2 | 3307.4.6 PROHIBITED SIGNS.(3301.9.7).AT TIME OF MY INSPECTION I OBSERVED A SIDEWALK SHED AT A OCCUPIED BUILDING.I NOT... | $2,500 | $0 | Dec 19, 2025 |
| Aug 3, 2022 | 35664030K | RESOLVE | CLASS - 1 | FAILURE TO TAKE REQUIRED ACTION TO SECURE PUBLIC SAFETY-UNSAFE FACADE.NOTE:AS PREV VIO35651299K ISSUED5/16/22&AS TODA... | $10,000 | $0 | Dec 2, 2022 |
| May 16, 2022 | 35651299K | RESOLVE | CLASS - 1 | FAILURE TO TAKE REQUIRED ACTION TO SECURE PUBLIC SAFETY UNSAFE FACADE OBSERVED NO SAFETY MEASURES IN PLACE AROUND BUI... | $10,000 | $0 | Aug 5, 2022 |
| Jan 27, 2022 | 39055077J | RESOLVE | CLASS - 2 | PHONE NOT WORKING | $310 | $0 | May 20, 2022 |
| Oct 7, 2021 | 39048857P | RESOLVE | CLASS - 2 | FOUND CORRODED AND LEAKING RETURN LINE AT REAR OF BOILER, CORRODED PIPING ON FEED LINE ON SIDE OF BOILER, COIL PIPING... | $312 | $0 | Dec 3, 2021 |
| Oct 7, 2021 | 39048858R | RESOLVE | CLASS - 2 | FOUND CORRODED COIL PIPING LEAKING ON TO BURNER MOTOR, DIRTY GLASS GAUGE, CORRODED AND LEAKING FEED LINE ON SIDE OF B... | $312 | $0 | Dec 3, 2021 |
| Jun 1, 2021 | 37021667L | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Nov 12, 2021 |
| Sep 1, 2019 | 38271287H | RESOLVE | CLASS - 1 | 97-X-17 DEVICE IS FOUND TO BE OUT-OF-SERVICE CREATING A HAZARDOUS CONDITION AS PER 1RCNY 11-02 REMEDY: RESTORE IMMEDI... | $1,250 | $0 | Oct 18, 2019 |
| Oct 17, 2017 | 38258807X | RESOLVE | CLASS - 2 | 42B10,70Z02,53B14,53M07,52M07,57BB11,59U15,56Y13.(42)REPAIR DOOR NOT TO RECALL ON PHASE I FIRE SERVICE.(57)REPLACE FI... | $250 | $0 | Jan 19, 2018 |
| Oct 17, 2017 | 38258806Y | RESOLVE | CLASS - 2 | 42B10.(42B10)REPAIR DOOR POSITION MONITOR NOT TO RECALL ON PHASE I.FIRE SERVICE WITH THE HOIST DOOR COUPLE EXEPT ON P... | $0 | $0 | Jan 19, 2018 |
| Oct 16, 2017 | 38258802R | RESOLVE | CLASS - 1 | C/U 05A10,C/U 42B10,59BB15,56Y13,57BB11,56D06.(05A10)(42B10)CEASE USE ITEMS.DOOR ZONE RESTRICTOR HAS BEEN ALTERED & R... | $1,000 | $0 | Jan 19, 2018 |
| Sep 15, 2017 | 35244787L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG CODE COMPLIANT: USE OF PROHIBITED HARDWARE PER BC 1008.1.8;27-371(J). NOTED: AT REAR APT#2A ... | $500 | $0 | Nov 3, 2017 |
| Mar 9, 2017 | 38253605P | RESOLVE | CLASS - 2 | 97X10 RESTORE BACK TO SERVICE IMMEDIATELY. | $250 | $0 | May 5, 2017 |
| Mar 25, 2016 | 38241696L | RESOLVE | CLASS - 1 | CU-66H11. ROPE GRIPPER PADS WORN/COPE GRIPPER NOT RESETTING/REPLACE. UNABLE TO COMPLETE INSPECTION. | $1,000 | $0 | Dec 30, 2016 |
| Jan 5, 2016 | 35158705H | RESOLVE | CLASS - 1 | SEPARETLY DERIVED SYSTEMS.SEPARATELY DERIVED SYSTEMS,IS COVERED IN 250.20(A) OR (B),SHALL BE GROUNDED AS SPECIFIED IN... | $1,600 | $0 | Feb 19, 2016 |
| Jan 5, 2016 | 35158704X | RESOLVE | CLASS - 1 | ELECTRICAL WORK DOES NOT CONFORM TO APPROVED SUBMITTAL DOCUMENTS/AMENDMENTS.CELLAR CO GENERATION SYSTEM NO ADVISORY B... | $1,000 | $0 | Feb 19, 2016 |
| May 19, 2014 | 35024470Z | RESOLVE | CLASS - 2 | REMOVAL OF THE SHED OR PROTECTIVE MEASURE W/O DEPT APPROVAL.SHED HAS BEEN REMOVED W/O DOB APPROVAL & BEFORE THE AMEND... | $400 | $0 | Jul 18, 2014 |
| Nov 21, 2013 | 34984593K | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS FOR ALT II JOB #220202224 FOR WHI... | $500 | $0 | Jan 17, 2014 |
| May 16, 2012 | 38221648Z | RESOLVE | CLASS - 2 | 70O02,99BB05,44H08,100X10,16L10,68M07: 100;RESTORE EMERGENCY COMMUNICATION PHONE IN ELEV CAB TO AN OUTSIDE SOURCE. 16... | $500 | $0 | Jul 6, 2012 |
| May 16, 2012 | 38221647R | RESOLVE | CLASS - 2 | 70O02,99BB05,56B02,56Y13,100X10,16L10,17H10,68M07: 100;RESTORE EMERGENCY COMMUNICATION PHONE IN ELEV CAB TO AN OUTSID... | $500 | $0 | Jul 6, 2012 |
| Oct 3, 2011 | 32071352K | RESOLVE | CLASS - 2 | B254,32A,34B,44C,46B,50A,B,C. 50A- DEFECTIVE PUMP. 46B- DEFECTIVE TRI-COCK. 50B- DEFECTIVE SMOKE ALARM. 50C- CHIMNEY ... | $500 | $0 | May 25, 2012 |
| Oct 3, 2011 | 32071351Z | RESOLVE | CLASS - 2 | B254,32A,34B,44C,46B,50A,B,C. 50A- DEFECTIVE PUMP, 50B- DEFECTIVE SMOKE ALARM. 50C- CHIMNEY BASE CLOGGED. 46B- 2 DEFE... | $500 | $0 | May 11, 2012 |
| Aug 23, 2011 | 38217689N | RESOLVE | CLASS - 2 | 57Q03,50Q03,67M07,100M07. 57Q03- INSTALL COVERS FOR HOIST MOTOR COMMUTATOR. 50Q03- INSTALL COVERS FOR GENERATOR COMMU... | $0 | $0 | Oct 21, 2011 |
| Aug 23, 2011 | 38217688L | RESOLVE | CLASS - 2 | 21M11,42D06,57Q03,67M07,100M07. 21M11- REPLACE INTERLOCK COVER FOR BASEMENT INTERLOCK. 42D06- SECURE RELAY ON BACK OF... | $0 | $0 | Oct 21, 2011 |
| Mar 18, 2011 | 38214141Y | RESOLVE | CLASS - 2 | 16M07/ SPACE GUARD MISSING ON MOST FLOORS OR HOISTWAY DOORS PROVIDE | $0 | $0 | May 6, 2011 |
| Mar 18, 2011 | 38214140M | RESOLVE | CLASS - 2 | 16M07/ GAP SPACE GUARD MISSING ON MOST FLOORS PROVIDE " HOISTWAY DOORS" | $0 | $0 | May 6, 2011 |
| Feb 11, 2011 | 38215182P | RESOLVE | CLASS - 2 | 44H11 52H11 57H10 42G11 99B5 68B11 8V1 16M7 24B10 12Q3 35Q3 100M7 71M7. 16-SIGHT GUARDS. 100-TOE GUARD MISSING. | $250 | $0 | Jun 17, 2011 |
| Feb 11, 2011 | 38215181N | RESOLVE | CLASS - 2 | 68B11 42G11 99B5 58H11 35Q3 100M7 32H11 16M7 28H10 24B10 12Q3 70Z9 71M7. 100-TOEGUARD MISSING. 16-SIGHT GUARDS. | $250 | $0 | Jun 20, 2011 |
| Sep 8, 2010 | 38212111Y | RESOLVE | CLASS - 2 | 97X10,70O2,70Z9. 97- RESTORE TO SERVICE SO A FULL INSPECTION CAN BE MADE BY THIS DEPT | $0 | $0 | Oct 29, 2010 |
| Aug 27, 2010 | 38212686P | RESOLVE | CLASS - 2 | 97X10. 97X10- ONE OF TWO ELEVATORS SERVING AN 18 STY HIGH RISE BLDG. IS OUT OF SERVICE. REPAIR AND RESTORE TO SERVICE... | $250 | $0 | Oct 15, 2010 |
| Feb 12, 2010 | 38209168H | RESOLVE | CLASS - 2 | 44H10.52H11.10H7.17H7.08V10.70Z9.10H7 CAR DOOR GIBS ARE WORN PROVIDE 17H9 HOISTWAY DOOR GIBS ARE EWORN REPLACE WERE N... | $2,500 | $0 | Apr 2, 2010 |
| Dec 1, 2009 | 38207373H | RESOLVE | CLASS - 1 | 46L10,29O02,70O02,71L10. 46L10-REPAIR GOVERNOR SWITCH. | $5,000 | $0 | Jan 22, 2010 |
| Dec 1, 2009 | 38207372X | RESOLVE | CLASS - 2 | 26D06,41D06,39O02,70O02,79E10,20I11,42G11.26D06-SECURE TOP EXIT COVER.79E10-REPAIR COMP CHAIN RUBBING. 20I11- REPLACE... | $2,500 | $0 | Jan 22, 2010 |
| Jul 28, 2009 | 38204755J | RESOLVE | CLASS - 2 | 42Q3.42G11.44H11.52H11.68M7.16M7.14M7.39O2.10O2.70O2.42 JUMPER FUSE | $2,500 | $0 | Sep 18, 2009 |
| Jul 28, 2009 | 38204754H | RESOLVE | CLASS - 2 | 42G11.68M7.58B10.28H11.40O2.70O2.28 LOBBY CAR DOOR | $2,500 | $0 | Sep 18, 2009 |
| Jul 29, 2008 | 38189624R | RESOLVE | CLASS - 2 | 4I10.100I10.7B10.39P7. 4I SIDE EMG. DOOR DAMAGED NEEDS REPAIR 100I CARFAN COVER DAMAGED NEEDS REPAIR 7B SAFETY EDGE N... | $250 | $0 | Jan 16, 2009 |
| Jul 29, 2008 | 38189959Z | RESOLVE | CLASS - 2 | 100L SIDE EMG. DOOR IS DAMAGED NEED TO BE REPAIRED 7B SAFETY EDGE NEEDS ADJUSTMENT HOISTWAY DOOR LEADS BEFORE SAFETY | $250 | $0 | Jan 16, 2009 |
| Apr 23, 2008 | 38183471H | RESOLVE | Non-Hazardous | 41L10.85BB05.86BB05.11D06.66O02.66Z09. 41L10 REPAIR 3A & 4A RELAYS ON CONTROLLER SO ELEVATOR CAN RUNNING AT PROPER SP... | $350 | $0 | Jan 16, 2009 |
| Apr 23, 2008 | 38183472J | RESOLVE | Non-Hazardous | 83X10.52I11 83X10 RETURN ELEVATOR TO SERVICE CALL DOB WHEN ELEVATOR ISRESTORED FOR PROPER INSPECTION OF ELEVATOR AT 2... | $350 | $0 | Jan 16, 2009 |
| Apr 2, 2008 | 34418767P | RESOLVE | Hazardous | LOCAL LAW REPORT FILED AS "UNSAFE" UNSAFE CONDITION EXISTS AND NO MEASURES TAKEN TO SECURE SAFETY OF PUBLIC AS PER 27... | $2,500 | $0 | May 30, 2008 |
| Sep 26, 2007 | 38168968H | RESOLVE | Non-Hazardous | 85BB5/86BB5/41B10/56B10/49B11/7B1/16B11/32O2/33O2/35O2/38O2/39O2/66O2/67O2/68O2/69O2/71O2/.41-CAR SPEED 350 FPM CAR R... | $2,500 | $0 | Nov 16, 2007 |
| Sep 26, 2007 | 38168969J | RESOLVE | Non-Hazardous | 85BB5/86BB5/51H11/43H9/43H11/41B1/16B1/32O2/33O2/35O2/38O2/39O2/66O2/67O2/68O2/69O2/71O2/.41-ELEV RUN 225 NOT 350 FPM... | $2,500 | $0 | Apr 4, 2008 |
| Aug 15, 2007 | 34589356R | RESOLVE | Hazardous | B5U-SECTION 27-596 & 27-597.QUESTIONABLE CONSTRUCTION PRACTICES.1' SCAFFOLD ERECTED IN REAR OF PREMISES IS IMPROPERLY... | $0 | $0 | Oct 26, 2007 |
| Jul 18, 2007 | 34589052H | RESOLVE | Non-Hazardous | QUESTIONABLE CONSTRUCTION PRACTICES. ONE TIER SCAFFOLD ERECTED AT REAR OF PREMISES IS IMPROPERLY ERECTED & HAZARDOUSL... | $0 | $0 | Oct 26, 2007 |
| May 2, 2005 | 38152261H | RESOLVE | Non-Hazardous | 43H9/43H11/51H11/41G11/32O2/33O2/35O2/38O2/66O2/67O2/69O2 | $350 | $0 | Jun 17, 2005 |
| May 2, 2005 | 38152262J | RESOLVE | Non-Hazardous | 57H11/41G11/55Y13/34Q3/10H11/34H11 84 CAR SADDLE WORN | $350 | $0 | Jun 17, 2005 |
| Jan 18, 2005 | 38150679X | RESOLVE | Non-Hazardous | 14M07/25L06/43H08/51H11/52B14/38O02/66O02/64M11 | $2,500 | $0 | Mar 4, 2005 |