Maintenance code violations
1516-1520 Sedgwick Avenue, Bronx • Block 02880 • Lot 0017
937 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Mar 15, 2021 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2... | 17A | Jun 18, 2021 |
| Mar 15, 2021 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT APT 17A, 17th STORY, 1st APARTMENT F... | 17A | Apr 10, 2021 |
| Mar 15, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE AIR VALVE AT RADIATOR LOCATED AT WEST IN THE 1st ROOM FRO... | 17A | Apr 19, 2021 |
| Mar 15, 2021 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASE CABINET LOCATED AT NORTH WALL IN THE KITCHEN LOCATED ... | 17A | Jun 18, 2021 |
| Mar 12, 2021 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ROTTED WOOD FLOOR IN THE 1st ROOM FR... | 17A | Jun 15, 2021 |
| Mar 12, 2021 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE LOCATED AT APT 17A, 17th STORY, 1st APARTMENT FROM... | 17A | Apr 7, 2021 |
| Mar 12, 2021 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 17A, 17th STORY... | 17A | Mar 12, 2021 |
| Mar 12, 2021 | C | VIOLATION DISMISSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCATED AT BASEMENT. | — | Mar 18, 2021 |
| Mar 9, 2021 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT... | 12E | Apr 13, 2021 |
| Mar 9, 2021 | A | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... IN... | 12E | Jun 12, 2021 |
| Mar 9, 2021 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE UNHINGED DOOR AT CLOSET LOCATED AT EAST WALL IN THE 2nd RO... | 12E | Apr 13, 2021 |
| Mar 9, 2021 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE... | 12E | Apr 13, 2021 |
| Feb 19, 2021 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 10E | May 25, 2021 |
| Feb 19, 2021 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX, 8 SQ.FT. AT THE CEILING ... | 10E | May 25, 2021 |
| Feb 19, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING, SOU... | 10E | Mar 26, 2021 |
| Feb 19, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE FLICKERING LIGHT FIXTURE AT THE CEILING IN THE 1st ROOM FR... | 10E | Mar 26, 2021 |
| Feb 19, 2021 | B | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | 10E | Mar 26, 2021 |
| Feb 19, 2021 | B | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | 10E | Mar 26, 2021 |
| Feb 19, 2021 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 10E | Mar 17, 2021 |
| Feb 19, 2021 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE EN... | 10E | Mar 17, 2021 |
| Feb 3, 2021 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 13E, 13th STORY... | 13E | Feb 3, 2021 |
| Feb 3, 2021 | C | VIOLATION DISMISSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT | — | Feb 9, 2021 |
| Feb 3, 2021 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 10E, 10th STORY... | 10E | Feb 3, 2021 |
| Feb 1, 2021 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM S... | 3B | Feb 27, 2021 |
| Feb 1, 2021 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FRO... | 3B | Feb 27, 2021 |
| Jan 26, 2021 | C | VIOLATION DISMISSED | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... | — | Feb 1, 2021 |
| Jan 26, 2021 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 8A, 8th STORY, ... | 8A | Jan 26, 2021 |
| Jan 26, 2021 | C | VIOLATION DISMISSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED AT BASEMENT | — | Feb 1, 2021 |
| Jan 22, 2021 | B | VIOLATION DISMISSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND NORTH WALL (APPRX... | 11A | Feb 26, 2021 |
| Jan 7, 2021 | B | VIOLATION DISMISSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATH TUB IN THE BATHROOM LOCATED AT APT 15F, 15th STO... | 15F | Feb 11, 2021 |
| Jan 4, 2021 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE REFIT CLOSET DOOR IN THE PRIVATE HALLWAY LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM EAST AT ... | 5A | Apr 9, 2021 |
| Jan 4, 2021 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WALL CABINET DOOR AT NORTH WALL IN T... | 5A | Feb 8, 2021 |
| Jan 4, 2021 | B | VIOLATION DISMISSED | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB WASTELINE IN THE BATHROOM LOCATED AT APT... | 5A | Feb 8, 2021 |
| Dec 22, 2020 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STO... | 5A | Jan 17, 2021 |
| Dec 22, 2020 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT NORTH WALL IN THE B... | 5A | Jan 26, 2021 |
| Dec 21, 2020 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | — | Dec 27, 2020 |
| Dec 21, 2020 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 17D, 17th STORY... | 17D | Dec 19, 2020 |
| Dec 21, 2020 | C | VIOLATION CLOSED | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 17D, 1... | 17D | Dec 19, 2020 |
| Dec 21, 2020 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CLOSET DOOR AT WEST WALL IN THE PRIVATE HALLWAY LOCATED AT... | 5A | Jan 25, 2021 |
| Dec 17, 2020 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... IN... | 5A | Jan 21, 2021 |
| Dec 14, 2020 | C | VIOLATION DISMISSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STO... | 5A | Jan 9, 2021 |
| Nov 25, 2020 | C | VIOLATION DISMISSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT CELLAR AT BOILER ROOM | — | Dec 1, 2020 |
| Nov 25, 2020 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6C, 6th STORY, ... | 6C | Nov 25, 2020 |
| Nov 10, 2020 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FRO... | 9E | Nov 16, 2020 |
| Nov 10, 2020 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX. 7 SQ. FT. IN ... | 9E | Feb 13, 2021 |
| Oct 15, 2020 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL IN THE 1st BA... | 5A | Jan 18, 2021 |
| Sep 24, 2020 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASH BASIN IN THE 1st BATHROOM FROM EAST AT CENTER LOCATED AT APT 11A, 1... | 11A | Oct 29, 2020 |
| Sep 24, 2020 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NOR... | 11A | Dec 28, 2020 |
| Sep 24, 2020 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND NORTH WALL (APPRX... | 11A | Dec 28, 2020 |
| Sep 24, 2020 | C | VIOLATION DISMISSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRA... | 11A | Oct 20, 2020 |