Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 27, 2024 39531910P RESOLVE CLASS - 2 CORNER EXP3,4 AT REAR YARD MISSING SECTION OF SCAFFOLD ALTERNATIVE .NOT FULLY ENCLOSING BUILDING PER BC3308.6.1.4 STI... $2,500 $0 Nov 1, 2024
Aug 27, 2024 39531911R RESOLVE CLASS - 2 EXP1 SWS STOPS AT PROPERTY LINE AND DOES NOT EXTEND 5 FEET BC3307.6.3 STIPULATES DECKING OF SIDEWALK SHED SHALL EXTEN... $2,400 $0 Nov 1, 2024
Jul 31, 2024 39530992N RESOLVE CLASS - 2 3301.6 DESIGN, AND CAPACITY- OBSERVED SUPPORTED SCAFFOLDING APPROX. 75 IN HEIGHT INSTALLED @ ALL 4 EXPOSURES OF ACTIV... $2,500 $0 Mar 4, 2025
Jul 31, 2024 39531002J RESOLVE CLASS - 2 28-110.2 PHASED SITE SAFETY PLANS- OBSERVED CRANE IN USE AT EXPOSURE 3 OF JOBSITE STREET LEVEL AT CARTER AVENUE. UPON... $0 $0 Mar 4, 2025
Jul 31, 2024 39530993P RESOLVE CLASS - 2 OBSERVED SIDE WALK SHED INSTALLED @ EXPOSURE 1 OF JOBSITE WITH TRUST INSTALLED AT MID SECTION. UPON REVIEW OF PROVIDE... $0 $0 Oct 18, 2024
Jul 31, 2024 39530998Y RESOLVE CLASS - 2 3301.4 INSPECTION- OBSERVED FALL PROTECTION INSTALLED AROUND PERIMETER OF JOBSITE AT LEADING EDGE WITH WORKERS TIED O... $2,500 $0 Mar 4, 2025
Jul 12, 2024 39119055Z RESOLVE CLASS - 2 2" RGD INSUL R10 INSTD 3" R15 ON CMU WAL EXT OUTBORD INSUL EAST EXP#2 WZ ADJ BLDNG FROM GROUND- ADJ BLDG. HIGHEST C -... $1,250 $0 Feb 27, 2025
Jul 9, 2024 39118789N RESOLVE CLASS - 1 NOTED AT A 9 STORY NB THAT THE HOUSEKEEPING WAS INADEQUATE WITH MATERIAL COMPLETELY BLOCKING AREAS AT EXP 2 AND FLAMM... $2,500 $2,500 Sep 1, 2026
Jul 9, 2024 39118791M RESOLVE CLASS - 1 NOTED ON 9FL NB W/ ACTIVE CRANE WORK -SITE SAFETY PLAN DIDN'T CONFORM TO SITE CONDITIONS (SKYLIFT/BOOM LIFT ON SITE E... $2,500 $2,500 Sep 1, 2026
Jul 9, 2024 39118790K RESOLVE CLASS - 1 NOTED ON 9 STORY NB THAT CRANE WORK OCCURRED OVERHEAD, WITH MATERIAL STORED/MOVING WITH FORKLIFT ON STREET, WITHOUT B... $5,000 $5,000 Sep 1, 2026
Jul 9, 2024 39118788L RESOLVE CLASS - 2 NOTED ON 9 STORY NB JOB THAT SUPER WAS UNABLE TO PROVIDE A SIGNED OR ADEQAUTE DAILY LOG FOR PAST 3 DAYS, ENSURE WORKE... $5,000 $5,000 Sep 1, 2026
Jun 14, 2024 39529728X RESOLVE CLASS - 2 EXP3 PALLETS AND CONSTRUCTION MACHINERY STORED ADJACENT TO PUBLIC SIDEWALK MISSING BARRIER AND HALF INCH MESH REQ.PER... $2,500 $0 Aug 30, 2024
Jun 7, 2024 39529421L RESOLVE CLASS - 1 AT TIME OF INSPECTION OF 9 STORY NEW BUILDING AT 6 FLOOR LEVEL OBSERVED AREA WHERE WORKER FELL FROM SUPPORTED SCAFFOL... $12,500 $0 Sep 29, 2026
Mar 27, 2023 39514663M RESOLVE CLASS - 2 AT TIME OF COMPLAINT INSPECTION I OBSERVED TEMP FENCE ERECTED AT EXPO 4 NEXT TO ADJACENT PROPERTY CONSISTING OF CHAIN... $0 $0 Jun 2, 2023
Mar 27, 2023 39514662K RESOLVE CLASS - 1 AT TIME OF COMPLAINT INSPECTION I OBSERVED ACTIVE JOBSITE AT EXCAVATION PHASE UPON MY INSPECTION I OBSERVED WALL OF A... $10,000 $0 Oct 20, 2023
Dec 15, 2022 39511593M RESOLVE CLASS - 2 UPON INSPECTION RESPONDING TO A INCIDENT INVOLVING A WORKER FATALITY NOTED JOBSITE FENCE MISSING AT EXPOSURE#4 AT ADJ... $0 $0 Mar 31, 2023
Dec 15, 2022 39511658Y RESOLVE CLASS - 1 UPON INSPECTION AND REVIEW OF DEPARTMENT RECORD NOTED THE CONSTRUCTION SUPER FAILED TO NOTIFY THE DEPARTMENT OF AN IN... $0 $0 Feb 9, 2024
Dec 15, 2022 39511592K RESOLVE CLASS - 1 UPON INSPECTION AND REVIEW OF DEPARTMENT RECORDS NOTED THE PERMIT HOLDER FAILED TO NOTIFY THE DEPARTMENT OF A INCIDEN... $5,000 $0 Nov 15, 2024
Dec 15, 2022 39511594Y RESOLVE CLASS - 1 AT TIME OF INSPECTION AT ACTIVE JOBSITE AT EXCAVATION PHASE I OBSERVED EXCAVATION AND DRILLING IN PROGRESS. UPON REVI... $0 $0 Nov 15, 2024
Dec 15, 2022 39511591Z RESOLVE CLASS - 1 UPON INSPECTION AND REVIEW OF PRE-SHIFT SAFETY MEETING LOG NOTED THAT THE MEETING CONTENT ARE GENERIC FOR ALL TRADES ... $0 $0 Nov 15, 2024
Dec 15, 2022 39511590R RESOLVE CLASS - 1 UPON INSPECTION OF INCIDENT INVOLVING WORKER FATALITY NOTED THAT THE LOG FOR SITE SPECIFIC SAFETY ORIENTATION WAS INA... $0 $0 Nov 15, 2024
Dec 15, 2022 39511583Z RESOLVE CLASS - 1 INSPECTION REVEALED THE FOLLOWING SAFETY ISSUES CONTRIBUTED TO THE INCIDENT WHERE WORKER GOT INJURED. 1) WORKER DID N... $0 $0 Nov 15, 2024