ECB violations

1802 Crotona Avenue, Bronx • Block 02948 • Lot 0003

39 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
May 27, 2026 39190045R ACTIVE CLASS - 1 ATOI OBSERVED IN BASMENT OBSTRUCTED SPRINKLER HEADS IN BOILER ROOM AND PVC PIPE BEING USED ON EJECTOR PUMP.PER PC 712... $2,500 $2,500 Aug 21, 2026
Jun 13, 2025 39151086L RESOLVE CLASS - 1 SUMMONS ISSUED FOR FAILURE TO PROVIDE UNOBSTRUCTED PASSAGEWAY DUE TO HALLWAY LEADING OUT TO EXIT PASSAGEWAY PARTIALLY... $1,280 $1,280 Jul 16, 2026
Jun 3, 2025 39149753N RESOLVE CLASS - 2 CLASS 2 ITEMS: REPLACE WORN COUNTERWEIGHT GUIDE ROLLERS AS NEEDED. REPAIR SEPARATED EMT CONDUIT FOR PIT LIGHT FIXTURE. $0 $0 Aug 15, 2025
Apr 8, 2024 39111115P RESOLVE CLASS - 1 I OBSERVED ON THE ROOF THE USE OF FLEXIBLE CORDS TO SUPPLY POWER FROM THE OUTDOOR CONDENSER TO THE INDOOR WALL MOUNTE... $800 $0 Jan 20, 2026
Apr 8, 2024 39111118K RESOLVE CLASS - 1 I OBSERVED IN THE MAIN ELECTRICAL ROOM THE DATA WIRING AND EQUIPMENT STATED IN ECB# 39067272N ISSUED ON 08/10/2022 ST... $2,500 $0 Jan 20, 2026
Apr 8, 2024 39111119M RESOLVE CLASS - 1 I OBSERVED IN THE MAIN ELECTRICAL ROOM , DATA EQUIPMENT AND WIRING AS STATED IN PREVIOUS ECBS# 35373081K ISSUED ON 11... $800 $0 Jan 20, 2026
Apr 8, 2024 39111116R RESOLVE CLASS - 2 I OBSERVED IN THE BASEMENT BOILER ROOM AN ACTIVE LEAK FROM THE FIRST BOILER DUE TO A DEFECTIVE CONTROL SYSTEM ON THE ... $625 $0 Jan 20, 2026
Apr 8, 2024 39111120J RESOLVE CLASS - 1 I OBSERVED IN DOB RECORDS THE SUBMISSION OF A C OF C ON 09/19/2022 STATING THE RESPONDENT COMPLIED WITH ECB# 35373081... $0 $0 Apr 2, 2026
Apr 8, 2024 39111114N RESOLVE CLASS - 1 I OBSERVED IN DOB RECORDS THE SUBMISSION OF A C OF C FOR ECB #39067272N ISSUED ON 08/03/2022 STATING DATA EQUIPMENT I... $0 $0 Apr 2, 2026
Apr 8, 2024 39111117Z RESOLVE CLASS - 1 I OBSERVED IN DOB RECORDS THE FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDERS AS STATED IN ECB# 39067273P ISSUED ON ... $0 $0 Jan 20, 2026
Apr 8, 2024 39111113L RESOLVE CLASS - 2 I OBSERVED THE INSTALLATION OF BRANCH CIRCUIT WIRING, EQUIPMENT DISCONNECTS AND RACEWAYS TO SUPPLY POWER TO SPLIT A.C... $800 $0 Jan 20, 2026
Feb 8, 2024 39105617Y RESOLVE CLASS - 2 OBSERVED ACTIVE WATER LEAK IN THE BASEMENT/CELLAR. AS PER 102.3 OF THE PLUMBING CODE 102.3 MAINTENANCE. INSTALLATIONS... $0 $0 Apr 19, 2024
Aug 3, 2022 39067273P RESOLVE CLASS - 2 I OBSERVED IN THE ELECTRICAL ROOM THE VIOLATING CONDITIONS OF THE DATA EQUIPMENT FOR THE BUILDING SECURITY SYSTEMS ST... $0 $0 Sep 30, 2022
Aug 3, 2022 39067270J RESOLVE CLASS - 2 CELLAR LEVEL BOILER ROOM BOTH FIRE RATED DOORS HOLES CUT IN THEM AND MANUAL AIR LOUVERS INSTALLED NO RATING ON THEM, ... $0 $0 Sep 30, 2022
Aug 3, 2022 39067234M RESOLVE CLASS - 2 NEUTRALIZER DRAIN PIPING LEAKING UNDER BOILER-CONDENSATE DRAIN FROM AC UNIT LEAKING UNDER BOILER-FLOOD IN BOILER ROOM. $310 $0 Sep 30, 2022
Aug 3, 2022 39067272N RESOLVE CLASS - 1 I OBSERVED AT THE ENTRANCE OF ELECTRICAL EQUIPMENT ROOM THE DATA SERVER EQUIPMENT STILL IN PLACE. AS STATED IN ECB #3... $300 $0 Sep 30, 2022
Oct 23, 2019 39011670X RESOLVE CLASS - 2 I OBSERVED ON THE ROOFTOP AREA MULTIPLE DEFECTIVE EXHAUST FANS. ALSO NOTED IN 6TH FLOOR STAIRWELL A A MOTION SENSOR L... $400 $0 May 14, 2021
Jul 12, 2019 39005434N RESOLVE CLASS - 2 BOILER PIPING NEEDS MORE INSULATION- BOILER ROOM TOO HOT-INSUFFICIENT AMBIENT AIR TO BOILER ROOM ; CORRECT ALL VIOLAT... $0 $0 Aug 30, 2019
Jun 25, 2019 35423798K RESOLVE CLASS - 1 AN UNLAWFUL ACT.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. FAILURE TO CORRECT AND CERTIFY SUMMONS#35422403M... $2,500 $0 Sep 10, 2020
Jun 25, 2019 35423797Z RESOLVE CLASS - 1 ELECTRICAL WORK W/O A PERMIT.FOR THE INSTALLATION OF 46 METERS,TWO MAIN SERVICE DISCONNECT SWITCES,TWO ADDITIONAL DIS... $0 $0 Sep 10, 2020
May 7, 2019 35422403M RESOLVE CLASS - 1 FAILURE TO INSTALL GROUNDING ELECTRODE CONDUCTOR IN ACCORDANCE W/ SECTION. OBSERVED IN ELECTRIC METER ROOM IN SERVICE... $800 $0 Oct 11, 2019
Feb 28, 2019 35359828Z RESOLVE CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY W/ AN ORDER OF THE COMMISSIONER. IN 1/9/19 AN ADMINISTRATIVE CODE VIOLATION WAS ISSU... $0 $0 May 10, 2019
Feb 26, 2019 35386433H RESOLVE CLASS - 1 BUILDING OR OPEN LOT OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCYNOTED: AT TIME OF INSPECION I OBSERVED NEW BUIL... $625 $0 May 10, 2019
Jan 9, 2019 35359771R RESOLVE CLASS - 1 UNLAWFUL ACTS:FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.IN DECEMBER 18,2018,TWO VIOLATIONS WAS ISSUE TO THE... $0 $0 Mar 15, 2019
Dec 28, 2018 35373051J RESOLVE CLASS - 1 NEW BUILDING OR OPEN LOT OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY. OBSERVED NEW BUILDING CONSTRUCTED UNDER A... $3,125 $0 Feb 15, 2019
Nov 8, 2018 35373081K RESOLVE CLASS - 1 ELECTRICAL CLOSET NOT DEDICATED TO ELECTRICAL DISTRIBUTION EQUIPMENT ONLY.OBSERVED AT ENTRANCE OF ELECTRICAL EQUIPMEN... $1,200 $0 Feb 15, 2019
Nov 8, 2018 35372213Z RESOLVE CLASS - 1 NEW BUILDING OR OPEN LOT OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY.NOTED: NEW BUILDING CONSTRUCTED UNDER JOB ... $1,250 $0 Feb 15, 2019
Nov 8, 2018 35373083Y RESOLVE CLASS - 2 FAILURE TO PROVIDE/MAINTAIN ACCESS/WORK SPACE ABOUT ELECTRICAL EQUIPMENT.OBSERVED IN ELECTRICAL EQUIPMENT ROOM. OFFIC... $0 $0 Feb 15, 2019
Nov 8, 2018 35373082M RESOLVE CLASS - 1 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS DEVICES,APPLIANCES OR WIRING IN USE.OBSERVED TH... $400 $0 Feb 15, 2019
May 1, 2018 32096766L RESOLVE CLASS - 2 B254,50A-50E:AS PER CLASS 2(B254)28.301.1 FAILURE TO MAINTAIN;HOT WATER PIPING FROM STORAGE TANK NOT CAPPED.PRESSURE ... $0 $0 Jun 15, 2018
Sep 27, 2017 35293731N RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: LACK OF EMERGENCY LIGHTING FOR EXITS. EXIT DISCHARGES & PUBLIC COR... $250 $0 Nov 17, 2017
Sep 27, 2017 35293714L RESOLVE CLASS - 2 FAILUR ETO MAINTAIN BLDG IN CODE.COMPLIANT MANNER.OBSERVED IN SPRINKLER CONTROL ROOM TO SPARE SPRINKLER HEADS STORED ... $250 $0 Dec 1, 2017
Sep 27, 2017 35293713J RESOLVE CLASS - 2 FGC 411.1.MISC VIOS:RESIDENTIAL GAS FLEX USED ON COMMERCIAL EQUIPMENT.OBSERVED IN LAUNDRY ROOM RESIDENTIAL GAS FLEX H... $800 $0 Dec 1, 2017
Dec 20, 2016 35208071H RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER-OBSERVED ON 12-20-16 AT 11:40AM IN SPRINKLER ROOM-NO HEATING INSTAL... $1,000 $0 Feb 3, 2017
Dec 20, 2016 35208072J RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER-OBSERVED ON 12-20-16@ 11:45AM PVC PIPING INSTALL ON SPRINKLER DRAIN... $500 $0 Feb 3, 2017
Mar 19, 2015 35079362J RESOLVE CLASS - 2 FAILURE TO INSTALL GROUND-FAULT CIRCUIT INTERRUPTER(GFCI)PROTECTION ASREUIRED.THE ENTIRE BLDG TEMPORARY WIRING:NO GFC... $1,200 $0 May 15, 2015
Mar 19, 2015 35079361H RESOLVE CLASS - 1 ELECTRICAL WORK W/O A PERMIT.THE ENTIRE BLDG:SERVICE SWITCHES 2-400AMP,2 100AMP 1-200AMP SERVICE ENTRANCE CONDUCTORS,... $800 $0 May 15, 2015
Nov 9, 2007 34619329X RESOLVE Hazardous FAILURE TO MAINTAIN: DEFECT NOTED: METAL CHAIN LINK FENCE AROUND LOT IS RUSTED & OUT OF PLUMB & LEANING OUTWARDS TOWA... $2,000 $0 Mar 14, 2008
Jul 20, 2007 34589058Z RESOLVE Hazardous FAILURE TO MAINTAIN HAZARDOUS DEFECTS ARE METAL FENCE ERECTED ON THE NORTH & WEST ENDS OF LOT ARE RUSTED OUT OF PLUMB... $800 $0 Sep 21, 2007