Issued Violation Status Severity Description Penalty Balance due Hearing
Oct 16, 2025 39163871P RESOLVE CLASS - 1 CLASS 1 CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. RE... $1,250 $1,250 May 1, 2026
Aug 24, 2023 39093993M ACTIVE CLASS - 2 I OBSERVED ON THE ROOFTOP THE RACEWAY SUPPLYING POWER TO THE EXHAUST FAN NOT PROPERLY SUPPORTED OR SECURED AS REQUIRE... $4,000 $0 Nov 17, 2023
Aug 24, 2023 39093991Z ACTIVE CLASS - 1 I OBSERVED IN THE REAR COURTYARD THE INSTALLATION OF BRANCH CIRCUIT WIRING, RACEWAYS, DISCONNECT SWITCHES TO SUPPLY P... $8,000 $0 Nov 17, 2023
Aug 24, 2023 39093992K ACTIVE CLASS - 1 I OBSERVED IN THE REAR YARD THE USE OF FLEXIBLE WIRING TO SUPPLY POWER FROM THE SPLIT UNIT A.C. CONDENSER TO THE INDO... $8,000 $0 Nov 17, 2023
Apr 6, 2023 39083186R ACTIVE CLASS - 2 AS PER ONE MODULAR SLANT/FIN HEATING BOILER. ONE MODULE IS LEAKING AND FLOODING UP BOILER ROOM FLOOR. $625 $0 Aug 4, 2023
Feb 23, 2022 35644412H RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED FIRE PROOF SELF-CLOSING SYSTEM AT 3RD FLOOR LOURGE ROO... $0 $0 May 20, 2022
Nov 8, 2021 35635950K RESOLVE CLASS - 1 FGC411.1 I OBSERVED@MAIN LEVEL IN LAUNDRYRM RESIDENTIAL GAS FLEX USED ON COMMERCIAL LAUNDRY EQUIPMENT AS PER FGC411.1... $2,500 $0 Mar 4, 2022
Oct 12, 2021 39049124M RESOLVE CLASS - 2 FOUND TO HAVE LEAKING RETURN LINE AT BOILER, BOILER ROOM DOOR NOT SELF CLOSING. $0 $0 Dec 3, 2021
Dec 22, 2020 39033761Z RESOLVE CLASS - 3 FOUND AT TIME OF INSPECTION THAT A UNION ON THE RETURN LINE IS LEAKING. $250 -$250 Feb 5, 2021
Aug 3, 2020 37020126Y RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39005232P ISSUED ON 7/10/2019,AND TO FILE ... $3,125 -$3,125 Oct 30, 2020
Sep 25, 2019 38271935R RESOLVE CLASS - 1 (C/U 16L10): (16,L,10) TOP FLOOR DOOR SPRING CLOSER DEFECTIVE BROKEN UNSAFE CONDITION $3,125 $0 Feb 21, 2020
Jul 10, 2019 39005232P ACTIVE CLASS - 2 FOUND BYPASS VALVE AT BACK FLOW PREVENTER, BACK FLOW PREVENTER SHALL NOT HAVE BYPASS VALVE. REMOVE ALL COMBUSTIBLE ST... $625 $0 Aug 30, 2019
Jun 18, 2019 37015169H RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #32097665R ISSUED ON 08-15-2018 AND TO FILE... $3,125 -$3,125 Sep 27, 2019
Apr 4, 2019 38268915M RESOLVE CLASS - 1 42.G.11:IMPROPER FUSES ON CONTROLLER $1,280 $0 May 31, 2019
Aug 15, 2018 32097665R ACTIVE CLASS - 2 32A.50A.50B.50C.50D-AS PER CLASS(B254)28.301.1 FAILURE TO MAINTAIN.32A:EXPOSED ELECTRICAL WIRING.50A:SPILL SWITCH INS... $625 $0 Oct 5, 2018
May 11, 2018 32096670R RESOLVE CLASS - 2 50. COMBUSTIBLE MATERIAL IN BOILER ROOM CORRECT ALL VIOLATING CONDITION & SUBMIT C OF C. $312 $0 Jun 29, 2018
Jan 2, 2018 35281692L RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35293712H ISSUED ON 09/27/17 & TO FILE A C OF C PURSUAN... $2,000 -$2,000 Feb 16, 2018
Nov 14, 2017 35280705R RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35293712H ISSUED ON 09/27/17 & TO FILE A C OF C PURSUAN... $2,000 $0 Jan 5, 2018
Sep 27, 2017 35293711X RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. OBSERVED THE TOP OF THE STAIRWELL WHERE THE INSPECTOR'S TEST IS LO... $1,250 $0 Nov 17, 2017
Sep 27, 2017 35293730L ACTIVE CLASS - 3 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: @ STAIRCASE'B' THROUGHOUT, SEVERAL STEP CRACK & HORIZONTAL ... $200 $0 Apr 13, 2018
Sep 27, 2017 35293712H ACTIVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.OBSERVED NO VENTILATION IN THE GAS METER ROOM AND THE ALARM C... $1,000 $0 Nov 17, 2017
Dec 20, 2016 35208069Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER FAILURE TO OBSERVED(LAW)OF DRAINAGE SYSTEM PER PC 702.1;27-911. COM... $500 $0 May 12, 2017
Dec 20, 2016 35208068R ACTIVE CLASS - 1 SEC. 408.2 MISC VIOLATION. OBSERVED ON 12/20/16 @ 10:45AM ON 1ST FL BOILER ROOM. FUTURE TEE & CAPS EXIST DOWN STREAM ... $800 $0 May 12, 2017
Dec 20, 2016 35222826H RESOLVE CLASS - 1 FGC411.1. MISCELL. VIO : OBSERVED ON 12/20/16 AT 10:45AM 1ST FL RESIDENTIAL GAS FLEX HOSES ON COMMERCIAL GAS DRYERS I... $4,000 -$4,000 Feb 17, 2017
Dec 20, 2016 35208073L RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. FAILURE TO HAVE FIXTURE TRAPED OR VENTED. OBSERVED ON 12/20/16, 10... $1,250 -$1,250 Feb 17, 2017
Dec 20, 2016 35208070X ACTIVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 12-20-16 @10:45AM FAILURE TO PROVIDE A SYSTEM OF AUTOM... $500 -$500 May 12, 2017