ECB violations
1791 Marmion Avenue, Bronx • Block 02952 • Lot 0056
26 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 22, 2023 | 39518100R | RESOLVE | CLASS - 1 | A WORKER INJURED DUE TO FORKLIFT TIPPED OVER DURING DELIVERY. PERMIT HOLDER JOB# 210177770 FAILED TO SUBMIT REPORT WI... | $12,500 | $12,500 | Jun 4, 2024 |
| May 24, 2023 | 39087082K | RESOLVE | CLASS - 2 | L-1 FAILURE TO SAFE GUARD WORKER EMPLOYED BY LE NOBLE LUMBER WAS OPERATING A FORK LIFT IN STREET WITHOUT ANY MATERIAL... | $0 | $0 | May 21, 2024 |
| Mar 24, 2023 | 39514562N | RESOLVE | CLASS - 1 | SANITARY FACILITIES. AT TIME OF INSPECTION I OBSERVED INADEQUATE SANITARY FACILITIES ( 2) WITH NO DESIGNATED ONE FOR ... | $2,530 | $0 | Feb 27, 2024 |
| Mar 24, 2023 | 39514561L | RESOLVE | CLASS - 2 | AT TIME OF COMPLAINT INSPECTION I OBSERVED ACTIVE EXTERIOR WORK GOING ON WITH WORKERS SCRAPPING/SHAVING STYROFOAM. I ... | $1,280 | $0 | Feb 27, 2024 |
| Mar 13, 2023 | 35653985J | RESOLVE | CLASS - 1 | FAILED TO NOTIFY THE DEPT OF AN INCIDENT THAT RESULTED IN A FATALITY OR INJURY. NOTE:A WORKER FELL OFF AN EXTENSION L... | $5,030 | $0 | Feb 27, 2024 |
| Feb 16, 2023 | 39513254R | RESOLVE | CLASS - 2 | FAIL TO INSTITUTE AND MAINTAIN SAFETY MEASURES. HANDRAILS. AT TIME OF INSPECTION I OBSERVED HANDRAILS IN STAIRCASE NO... | $3,125 | $0 | Oct 20, 2023 |
| Feb 16, 2023 | 39513253P | RESOLVE | CLASS - 2 | IN RESPONSE TO INCIDENT WHERE WORKER GOT INJURED WHILE ON A EXTENSION LADDER AT ROOF LEVEL APPROX. 13 FEET HIGH LOOKI... | $0 | $0 | Jun 18, 2024 |
| Dec 13, 2022 | 39510310Z | RESOLVE | CLASS - 2 | 7 STORY NB ACTIVE SITE. I OBSERVED PIPE SCAFFOLDING IN PLACE AT EXP#1,2,3,4. ALSO OBSERVED TRUSS SYSTEM INSTALLED AT ... | $0 | $0 | Feb 17, 2023 |
| Dec 13, 2022 | 39510313Y | RESOLVE | CLASS - 2 | A 7 STORY NB ACTIVE SITE. I OBSERVED LARGE AMOUNTS COMBUSTIBLE CONSTRUCTION MATERIALS WOOD CARDBOARD AND OTHER MATERI... | $0 | $0 | Feb 17, 2023 |
| Dec 13, 2022 | 39510303K | RESOLVE | CLASS - 2 | 7 STORY NB ACTIVE SITE. I OBSERVED SIDEWALK SHED/OVERHEAD PROTECTION WITH PIPE SCAFFOLD ON TOP AT EXP#1,2,4. ALSO NEE... | $0 | $0 | Feb 17, 2023 |
| Sep 16, 2022 | 39506425R | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, I OBSERVED INADEQUATE EGRESS LADDERS AT THE 2ND STORY UP TO THE 6TH FLOOR WORKING DECK. SSP RE... | $620 | $0 | Nov 4, 2022 |
| Sep 16, 2022 | 39506424P | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, I OBSERVE WORKERS DOING CONCRETE WORK AND WASHOUT OF CONCRETE TRUCK TAKING PLACE AT THE STREET... | $620 | $0 | Nov 4, 2022 |
| Aug 22, 2022 | 39505344K | RESOLVE | CLASS - 2 | FAILURE TO INSTITUTE SAFETY MEASURE : AT THE TIME OF INSPECTION AS PER CONSTRUCTION SUPERINTENDENT, WORKER DOING COLU... | $5,000 | $0 | Jan 12, 2024 |
| Aug 22, 2022 | 39505357J | RESOLVE | CLASS - 2 | UNCAPPED REBARS: AT THE TIME OF INSPECTION OBSERVED UNCAPPED REBARS ON 1ST FLOOR SITE ENTRANCE AREA AT EXPOSURE1 CREA... | $5,000 | $0 | Jan 12, 2024 |
| Aug 22, 2022 | 39505371X | RESOLVE | CLASS - 2 | NOTE: WORKER FELL FROM 4TH TO 2ND FLOOR, WENT TO HOSPITAL WHEN HE WAS WORKING ON AN UNSAFE PLATFORM. ACCIDENT HAPPENE... | $2,500 | $0 | Dec 17, 2024 |
| Aug 22, 2022 | 39505353M | RESOLVE | CLASS - 1 | NOTE: WORKER DOING COLUMN FORM WORK, STANDING ON UNSAFE SCAFFOLD PLATFORM, HAVE NO GR, MORE THAN 3FT GAP BETWEEN COLU... | $12,500 | $11,988 | Jan 12, 2024 |
| Jul 11, 2022 | 35663856M | RESOLVE | CLASS - 2 | CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE.NOTED:AT TIME OF INSPECTION OF ACTIVE CONSTRUCTION SITE... | $10,000 | $0 | Jul 17, 2023 |
| Jul 11, 2022 | 35663855K | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO GUARDRAILS.AS NOTED:AT TIME OF I... | $2,500 | $0 | Jul 17, 2023 |
| May 20, 2022 | 35650052Y | RESOLVE | CLASS - 1 | BC3309.14 WINDOW PROTECTION:ATO MY INSP OF 7STYNB BLDG@SUPERSTRUCTURE PHASE,I OBSERVED ON 2FL LEVEL CONCRETE SET FOR ... | $0 | $0 | Nov 4, 2022 |
| May 2, 2022 | 35651685Z | RESOLVE | CLASS - 1 | SUPERINTENDENT FAILURE TO PERFORM DUTIES.AT THE TIME OF INSPECTION I OBSERVED PROPOSED 7 STORY NEW BLDG W/WORK ACTIVI... | $10,000 | $10,000 | Sep 23, 2025 |
| May 2, 2022 | 35651684R | RESOLVE | CLASS - 1 | BC3301.1 RESPONSIBILITY FOR SAFETY(EGRESS,HOUSEKEEPING,FIRE EXTINGUISHERS & RIGGING FROM STREET).AT THE TIME OF INSPE... | $6,250 | $6,250 | Jul 28, 2025 |
| May 2, 2022 | 35651682N | RESOLVE | CLASS - 1 | 28-110.2 INADEQUATE PHASED SITE SAFETY PLAN.AT THE TIME OF INSPECTION I OBSERVED PROPOSED 7 STORY NEW BLDG W/WORK ACT... | $625 | $0 | Sep 23, 2022 |
| May 2, 2022 | 35651683P | RESOLVE | CLASS - 1 | BC3309.1 PROTECTION REQUIRED FOR ADJACENT PROPERTY.AT THE TIME OF INSPECTION I OBSERVED PROPOSED 7 STORY NB W/WORK AC... | $2,500 | $0 | Jan 27, 2023 |
| Mar 3, 2022 | 35643079Z | RESOLVE | CLASS - 1 | BC3301.13.1 SUOER FAILED TO PROVIDE SSP (LOW RISE) AS PER LOCAL LAW81OF2017-NO SSP ONSITE NOTED:ATOI OF PROPOSED 7STY... | $625 | $0 | Feb 10, 2023 |
| Mar 3, 2022 | 35643080X | RESOLVE | CLASS - 2 | CONST SUPER FAILED TO PERFORM DUTIES AS PER CODE-INADEQUATE CS LOGBOOKNOTED:ATOI OF PROPOSED 7STYNB ACTIVE JOBSITE@FO... | $2,500 | $0 | Feb 10, 2023 |
| Mar 3, 2022 | 35643081H | RESOLVE | CLASS - 2 | JOBSITE FENCE NOT CONST OR MAINTAINED PURSUANT TO SUBSEC-MISSING CONSTFENCE@EXP2 NOTED:ATOI OF PROPOSED 7STYNB.ACTIVE... | $0 | $0 | Jun 3, 2022 |