Skip to content

Maintenance code violations

866-876 Elsmere Place, Bronx • Block 02960 • Lot 0028

516 records

HPD grades a violation A for non-hazardous through C for immediately hazardous.

Issued Class Status Violation Apartment Correct by
Jun 25, 2018 A VIOLATION CLOSED § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AND MILDEW APPROX 1 SQ FT AT ... 3B Sep 28, 2018
Jun 25, 2018 A VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE... 3B Sep 28, 2018
Jun 25, 2018 A VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE 1st ROOM FROM N... 3B Sep 28, 2018
Mar 1, 2018 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WAL... 1C Apr 5, 2018
Mar 1, 2018 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ALL COUNTERBALANCES ON ALL LOWER WINDOW SASHES IN THE 2nd ... 1C Apr 5, 2018
Mar 1, 2018 A VIOLATION CLOSED § 27-2005 ADM CODE REFIT ALL UPPER AND LOWER WINDOW SASHES IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1C, 1st STORY, 1... 1C Jun 4, 2018
Mar 1, 2018 B VIOLATION CLOSED § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE ON HEAT RISER AT CEILING IN THE BATHROOM LOCATED AT ... 1C Apr 5, 2018
Mar 1, 2018 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WAL... 1C Apr 5, 2018
Mar 1, 2018 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILE - TRIP HAZARD IN TH... 1C Apr 5, 2018
Mar 1, 2018 C VIOLATION CLOSED § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RADIATOR AIR VALVE IN THE 1st ROOM FROM NORTH LOCATED AT ... 1C Mar 9, 2018
Mar 1, 2018 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE RADIATOR SHUT-OFF VALVE IN THE 1st ROOM FROM NORTH LOCATED... 1C Apr 5, 2018
Mar 1, 2018 B VIOLATION CLOSED § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROXIMATELY 4 SQ. FT. AT CE... 1C Apr 5, 2018
Mar 1, 2018 B VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND ALL WALLS IN TH... 1C Apr 5, 2018
Feb 6, 2018 A VIOLATION CLOSED § 27-2048 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS AT ALL STORIES AT PUBLIC HALL, SECTION ''BLDG#866'', AT WEST May 12, 2018
Feb 6, 2018 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE MARBLE TREAD 1ST UP FROM BOTTOM AT PUBLIC HALL STAIRS, 4th STORY, SECTIO... Mar 13, 2018
Oct 10, 2017 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT SOFFIT AT... Nov 14, 2017
Oct 10, 2017 A VIOLATION DISMISSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... 1D Jan 13, 2018
Oct 10, 2017 A VIOLATION CLOSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE SOFFIT AT PUBLIC HALL ST... Jan 13, 2018
Oct 10, 2017 A VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM RETURN SYSTEM AT WEST WALL IN THE ENTRANCE LOCATE... 1D Jan 13, 2018
Oct 10, 2017 A VIOLATION DISMISSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... 1D Jan 13, 2018
Oct 5, 2017 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE 2ND AT EAST SLIDE DRAWER, 2ND FROM TOP IN THE KITCHEN LOCA... 3B Nov 9, 2017
Oct 5, 2017 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE 1ST AT EAST LOWER BASE CABINET, 2ND FROM TOP IN THE KITCHE... 3B Nov 9, 2017
Oct 5, 2017 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ESCUTCHEON PLATE AT SINK IN THE KITCHEN LOCATED AT APT 3B, 3rd STORY, 2n... 3B Nov 9, 2017
Oct 5, 2017 A VIOLATION DISMISSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL IN THE KITCHEN... 3B Jan 8, 2018
Oct 5, 2017 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE 4TH AT EAST LOWER BASE CABINET DOOR IN THE KITCHEN LOCATED... 3B Nov 9, 2017
Oct 5, 2017 A VIOLATION DISMISSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE 1st ROOM ... 3B Jan 8, 2018
Oct 5, 2017 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER WINDOW COUNTERBALANCE AT WEST WINDOW IN THE 1st ROOM... 3B Nov 9, 2017
Oct 5, 2017 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BA... 3B Nov 9, 2017
Oct 5, 2017 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE UPPER WINDOW COUNTERBALANCE AT SOUTH WINDOW IN THE 1st ROO... 3B Nov 9, 2017
Oct 5, 2017 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER WINDOW COUNTERBALANCE IN THE BATHROOM LOCATED AT APT... 3B Nov 9, 2017
Oct 5, 2017 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE 1ST AT SOUTH UPPER WINDOW COUNTERBALANCE IN THE 1st ROOM F... 3B Nov 9, 2017
Oct 4, 2017 B VIOLATION DISMISSED § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WEST WALL IN THE KITCHEN LOCATED AT ... 3B Nov 8, 2017
Oct 4, 2017 B VIOLATION CLOSED § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRES AT ... Nov 8, 2017
Oct 4, 2017 B VIOLATION DISMISSED § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2n... 3B Nov 8, 2017
Oct 4, 2017 B VIOLATION DISMISSED § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 3B, 3rd STORY, 2nd... 3B Nov 8, 2017
Oct 4, 2017 B VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ELECTRICAL OUTLET PLATE AT EAST WALL IN THE KITCHEN LOCATED AT APT 3B, 3... 3B Nov 8, 2017
Sep 19, 2017 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE COUNTER TOP AT SINK IN THE KITCHEN L... 1A Oct 24, 2017
Sep 19, 2017 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MISSING FLOOR TILES IN THE KITCHEN L... 1A Oct 24, 2017
Jul 17, 2017 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATH... 8661W Aug 21, 2017
Jun 27, 2017 B VIOLATION CLOSED § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1s... 4E Aug 1, 2017
Jun 15, 2017 A VIOLATION CLOSED § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... Sep 18, 2017
Jun 6, 2017 B VIOLATION DISMISSED § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE E... 5B Jul 11, 2017
May 16, 2017 C VIOLATION CLOSED § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE AT SINK , IN THE KITCHEN LOCATED AT APT 4E... 4E May 24, 2017
May 15, 2017 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE (OFF TRACK ) WINDOW AT INTERMEDIATE LANDIN... Jun 19, 2017
May 15, 2017 B VIOLATION CLOSED § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING, LOCATED AT APT 4E, 4th STORY, AP... 4E Jun 19, 2017
Mar 8, 2017 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF A LOCKABLE SLIDEBOLT LOCK ASSEMBLY AT APARTMENT D... 5A Apr 12, 2017
Mar 8, 2017 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD STOOL AT WINDOW IN THE KITCHEN ... 5A Apr 12, 2017
Mar 7, 2017 B VIOLATION CLOSED § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 1C, 1st STO... 1C Apr 11, 2017
Mar 7, 2017 B VIOLATION CLOSED § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 1... 1C Apr 11, 2017
Mar 7, 2017 B VIOLATION CLOSED § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER FOR ELECTRIC LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT... 1C Apr 11, 2017