1419-1421 Prospect Avenue, Bronx
Bronx • Block 02962 • Lot 0038 • Zip: 10459
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 4 days ago- Grand Central 43 min 13 walking, 30 riding
- Times Square 45 min 13 walking, 32 riding
- Penn Station 46 min 13 walking, 33 riding
- Union Square 47 min 13 walking, 34 riding
- Fulton Street 53 min 13 walking, 40 riding
- Downtown Brooklyn 62 min 13 walking, 49 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Bus
Citi Bike
Activity
Sales, filings, permits and violations from every dataset, in one order.
2024
-
HPD violation Oct 30, 2024
Class B
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED...
2023
-
DOB violation Jun 20, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
2021
-
HPD violation Jun 29, 2021
Class B
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STOR...
-
HPD violation Jun 29, 2021
Class B
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED...
-
HPD violation Apr 5, 2021
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
-
HPD violation Feb 8, 2021
Class C
§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5t...
-
HPD violation Feb 8, 2021
Class B
§ 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE RADIATORS IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 1s...
2019
-
DOB violation Nov 8, 2019
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
2012
-
Alteration Type I
GUT REHAB EXISTING MULTIPLE DWELLING ASPER PLANS FILED HEREWITH.
-
Alteration Type II
INSTALL NEW SPRINKLER THROUGHOUTEXISTING MULTIPLE DWELLING AS PER PLANS FILED HEREWITH. NO CHANGE INUSE, EGRESS OR OC...
-
Alteration Type II
REPALCE OIL BURNER AND BOILER WITH TWO NEW BOILERS AND BURNERS AND REPLACE EXISTING OIL TANK. THIS APPLICATION SHALL ...
2011
-
Alteration Type III
INSTALLATION OF 53 LINEAR FEET OF HEAVY DUTY SIDEWALK SHED FOR REMEDIAL REPAIRS. SIDEWALK SHED SHALL COMPLY WITH LL33...
2010
2009
-
DOB violation Dec 31, 2009
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
-
DOB violation Dec 31, 2009
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
-
DOB violation Jan 1, 2009
LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
-
DOB violation Jan 1, 2009
LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
2008
-
Alteration Type II
REPLACE EXISTING STEAM BOILER WITH NEWHOT WATER BOILER. NO CHANGE IN USE OR MEAS OF EGRESS.
-
CLASS - 2
FAILED TO NOTIFY DEPT/OBTAIN PERMIT PRIOR TO USE/INST. OFF C-HOOKS/OUTRIGGER BEAMS IN CONNECTION WITH SUSPENDED SCAFF...
2005
-
Alteration Type II
Replace deteriorated metal chimney at the rear of building, as shown on plans provided. No changes to uses, egress or...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records