ECB violations
East 174 Street, Bronx • Block 03015 • Lot 0025
31 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 28, 2026 | 39557183N | ACTIVE | CLASS - 2 | OBSERVED JOBSITE APPROXIMATELY 7 STORIES HIGH WITH INCOMPLETE EXTERIOR WORK ALL EXPOSURES. AT EXPOSURE 1 THE PEDESTRI... | $2,400 | $2,400 | Oct 2, 2026 |
| Jan 22, 2026 | 39549385L | RESOLVE | CLASS - 2 | 3314.1- OBSERVED SUPPORTED SCAFFOLDING INSTALLED @ EXPO 4 OF JOBSITE APPROX. 78 FT IN HEIGHT. THE SCAFFOLD IS NOT ADE... | $2,500 | $2,500 | Jul 17, 2026 |
| Jan 22, 2026 | 39549386N | RESOLVE | CLASS - 2 | OBSERVED CONSTRUCTION FENCE INSTALLED AROUND PERIMETER OF JOBSITE. UPON REVIEW OF DOB RECORDS THE PERMIT OF CONSTRUCT... | $0 | $0 | Apr 3, 2026 |
| Oct 30, 2025 | 39546524Z | RESOLVE | CLASS - 2 | 3314.1- OBSERVED SUPPORTED SCAFFOLD INSTALLED @ EXPO 4 OF JOBSITE APPROX. 78 FT IN HEIGHT. SCAFFOLDING IS NOT MAINTAI... | $2,500 | $0 | Jan 16, 2026 |
| Oct 21, 2025 | 35718145L | RESOLVE | CLASS - 1 | FAILURE TO DESIGNATE AND/OR HAVE A CONSTRUCTION SUPERINTENDENT PRESENTAT JOBSITE AS REQUIRED.AS NOTED:AT TIME OF INSP... | $10,030 | $10,030 | Aug 3, 2026 |
| Apr 14, 2025 | 39539095Y | RESOLVE | CLASS - 1 | ATOI OBSERVED BUILDING CURRENTLY 10 STORY,NO STANDPIPE READY,REVIEWED ARCHITECTURAL AND STRUCTURAL PLANS REVEAL BUILD... | $5,000 | $5,000 | Dec 12, 2025 |
| Apr 14, 2025 | 39539094M | RESOLVE | CLASS - 1 | ATOI OBSERVED BUILDING CURRENTLY AT 10 STORY,REVIEWED ARCHITECTURAL AND STRUCTURAL PLANS REVEALED TOTAL STORIES BUILD... | $0 | $0 | Dec 12, 2025 |
| Mar 17, 2025 | 35716665X | ACTIVE | CLASS - 1 | UNLAWFUUL CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER. AS NOTED AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTI... | $10,030 | $10,030 | Oct 23, 2026 |
| Mar 16, 2025 | 39538044J | ACTIVE | CLASS - 2 | OBSERVED NB 8 STORY BUILDING,COUNT STORIES FROM WEST FARMS ROAD REVEALED WALKING FLOOR AT 10 STORY,REVIEWED APP.X0112... | $6,250 | $6,250 | May 30, 2025 |
| Mar 16, 2025 | 39538046N | ACTIVE | CLASS - 2 | OBSERVED NB 8 STORY BUILDING,COUNTING STORIES FROM WEST FARMS ROAD REVEALED WALKING FLOOR AT 10 STORY,REVIEWED ZD IN ... | $10,000 | $10,000 | Nov 20, 2026 |
| Mar 16, 2025 | 39538045L | ACTIVE | CLASS - 2 | OBSERVED 8 STORY NB,COUNTING STORIES FROM WEST FARMS ROAD REVEALED WALKING FLOOR AT 10 STORY,MISSING HORIZ.NETS OR SC... | $10,000 | $10,000 | May 30, 2025 |
| Oct 1, 2024 | 39532992M | RESOLVE | CLASS - 2 | 7 STORY BUILDING NOTICED STORAGE ZONE ADJACENT FROM SIDEWALK SHED NOT COMPLYING TO CODE3307.4.7(2),NO DOT PERMIT FOR ... | $2,400 | $0 | Dec 6, 2024 |
| Oct 1, 2024 | 39532993Y | RESOLVE | CLASS - 2 | 3308.5.3 I NOTICED A INADEQUATE CABLES VERTICAL SAFETY SYSTEM IN PLACE AT THE 5TH FLOOR OF A ACTIVE JOBSITE. I OBSERV... | $2,500 | $0 | Dec 6, 2024 |
| Oct 1, 2024 | 39532990Z | RESOLVE | CLASS - 1 | AT TIME OF MY INSPECTION I NOTICED AT 2ND FLOOR LEVEL A GAS CONTAINER FILLED WITH GASOLINE ON TOP OF WOODEN PILE.IMPR... | $2,500 | $0 | Dec 6, 2024 |
| Oct 1, 2024 | 39532989L | RESOLVE | CLASS - 1 | AT TIME OF MY INSPECTION OF A PROPOSED 7 STORY BUILDING AT 5TH FLOOR LEVEL. UPON REVIEWING APPROVED CRANE OPERATION P... | $2,500 | $0 | Nov 21, 2025 |
| Oct 1, 2024 | 39532984M | RESOLVE | CLASS - 1 | AT TIME OF MY INSPECTION OF A ACTIVE JOBSITE WITH A PARTIAL STOP WORK ORDER OF ALL STREET OPERATION AT EXP#1 .I NOTIC... | $5,000 | $0 | Nov 21, 2025 |
| Oct 1, 2024 | 39532991K | RESOLVE | CLASS - 2 | I NOTICED A MAKESHIFT PLATFORM MADE BY 3 WOODEN PALLETS AND WOOD ON TOP OF A PIPE SCAFFOLD USED TO STAND ON WHILE REC... | $5,000 | $0 | Nov 21, 2025 |
| Sep 27, 2024 | 39532886Z | ACTIVE | CLASS - 1 | BC 3307.2.1 FAILURE TO COMPLY WITH DOT REGULATIONS: AT TIME OF INSPECTION I OBSERVED ACTIVE MOBILE CRANE OPERATIONS I... | $2,500 | $0 | Dec 6, 2024 |
| Jul 11, 2024 | 35683752X | RESOLVE | CLASS - 2 | WORK NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS: AS NOTED AT TIME OF INSPECTION FOR AN... | $1,250 | $0 | Nov 8, 2024 |
| Jun 4, 2024 | 39529287J | RESOLVE | CLASS - 1 | 150PM OBSERVED 3 WORKERS AT 4 FLOOR WORKING DECK,REQUESTED FOR COMPENT PERSON TO WHICH WORKERS RESPONDED "WENT AWAY T... | $2,530 | $0 | Aug 16, 2024 |
| Jun 4, 2024 | 39529283M | RESOLVE | CLASS - 2 | EXP1 SWS NOT COVERING FULL WIDTH PUBLIC SIDEWALK ,REVIEWED ZD1 EXTERIOR WALL HEIGHT 44 FEET FROM CELLAR-2 STORY,RESID... | $2,400 | $2,400 | Feb 14, 2025 |
| Dec 5, 2023 | 39523857P | RESOLVE | CLASS - 1 | OBSERVED 3RD FL SLAB POURED AROUND ALL EXPOSURES. UPON REVIEW THE DEPARTMENT RECORDS OBSERVED SITE UNDER SWO COMPLAIN... | $5,000 | $0 | Mar 15, 2024 |
| Mar 1, 2022 | 35639509H | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.AT TIME OF INSPECTION OF NB OBSERVE... | $5,000 | $0 | Jun 24, 2022 |
| Nov 26, 2021 | 35633690Y | RESOLVE | CLASS - 2 | DOCUMENTS TO BE KEPT ONSITE.AT THE TIME OF MY INSPECTION,I OBSERVED ANEXCAVATOR IN OPERATION NEAR EXP1.HOWEVER,THE CO... | $625 | $0 | Feb 18, 2022 |
| Nov 26, 2021 | 35633692H | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS.AT THE TIME OF MY INSPECTION,I OBSER... | $625 | $0 | Feb 18, 2022 |
| Nov 26, 2021 | 35633691X | RESOLVE | CLASS - 2 | WORK CONTRARY TO CONSTRUCTION DOCUMENTS.AT THE TIME OF MY INSPECTION,IOBSERVED A MAJOR CONDITION THAT DID NOT CONFORM... | $620 | $0 | Feb 18, 2022 |
| Sep 27, 2021 | 35592800H | RESOLVE | CLASS - 1 | FAILURE TO PERFORM DUTIES OF CONSTRUCTION SUPERINTENDENTS. AT THE TIMEOF MY INSPECTION,I OBSERVED 3 WORKERS ON SITE W... | $500 | $0 | Jan 21, 2022 |
| Sep 27, 2021 | 35592801J | RESOLVE | CLASS - 2 | SEC. BC3303.7.2 INADEQUATE FIRE EXTINGUISHERS. AT THE TIME OF MY INSPECTION,I OBSERVED THAT THERE WERE NO INSPECTION ... | $620 | $0 | Dec 17, 2021 |
| Sep 27, 2021 | 35591549M | RESOLVE | CLASS - 1 | FAILURE TO PERFORM DUTIES OF CONSTRUCTION SUPERINTENDENTS AT THE TIME OF MY INSPECTION,I OBSERVED 3 WORKERS ON SITE W... | $2,500 | $0 | Jan 21, 2022 |
| Jul 19, 2021 | 35583337K | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. AT TIME OF INSPECTION AT PROPOSED 8 STORY BUILDI... | $0 | $0 | Oct 1, 2021 |
| Jun 21, 2021 | 35574500R | RESOLVE | CLASS - 1 | FAILURE TO COMMUNICATE REQUIRED INFORMATION TO WORKERS DURING PRE-SHIFT SAFETY MEETING AT TIME OF INSPECTION OF AN AC... | $2,500 | $0 | Oct 22, 2021 |