| Nov 3, 2022 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM L... | 2B | Feb 6, 2023 |
| Nov 3, 2022 | C | VIOLATION WILL BE REINSPECTED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE LOCATED AT APT 2B, 3rd STORY, 2nd APARTMENT FROM E... | 2B | Nov 29, 2022 |
| Nov 3, 2022 | C | VIOLATION WILL BE REINSPECTED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2B | Nov 29, 2022 |
| Nov 3, 2022 | B | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL/BUZZER INTERCOM SYSTEM FROM THE BUILDING ENTRANCE DOO... | 2B | Dec 8, 2022 |
| Nov 3, 2022 | C | VIOLATION WILL BE REINSPECTED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT APT 2B, 3rd STORY, 2nd APARTMENT FRO... | 2B | Nov 29, 2022 |
| Nov 1, 2022 | B | VIOLATION WILL BE REINSPECTED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE DRAIN PIPE AT SINK IN THE KITCHEN LOCATED ... | 3D | Dec 6, 2022 |
| Nov 1, 2022 | B | VIOLATION WILL BE REINSPECTED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE DRAIN PIPE AT WASH BASIN IN THE BATHROOM LOCA... | 3D | Dec 6, 2022 |
| Oct 7, 2022 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... NORTH AND WEST WALLS ( APPROX 12... | 4C | Nov 11, 2022 |
| Oct 7, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 4C | Oct 13, 2022 |
| Oct 7, 2022 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM ... | 4C | Jan 10, 2023 |
| Oct 7, 2022 | C | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRIC ... | 4C | Oct 13, 2022 |
| Oct 7, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CEILING LIGHT FIXTURE IN THE FOYER LOCATED AT APT 4C, 5th STORY, 1st ... | 4C | Nov 11, 2022 |
| Oct 7, 2022 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL AND INTERCOM SYSTEM AT SOUTH WALL IN THE FOYER LOCATE... | 4C | Jan 10, 2023 |
| Oct 7, 2022 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION DRAIN PIPE UNDER WASHBASIN IN THE BATHROOM LOCATED AT AP... | 4C | Nov 11, 2022 |
| Oct 7, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT STREET ENTRANCE DOOR TO BUILDING. | — | Oct 13, 2022 |
| Oct 3, 2022 | B | VIOLATION WILL BE REINSPECTED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... TEN SQUARE FEET AT CEILING; NORT... | 2D | Nov 7, 2022 |
| Oct 3, 2022 | C | DEFECT LETTER ISSUED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2D | Oct 27, 2022 |
| Oct 3, 2022 | C | DEFECT LETTER ISSUED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2D | Oct 27, 2022 |
| Oct 3, 2022 | A | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL, WEST... | 2D | Jan 6, 2023 |
| Oct 3, 2022 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT ... | 2D | Oct 27, 2022 |
| Oct 3, 2022 | C | DEFECT LETTER ISSUED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2D | Oct 27, 2022 |
| Oct 3, 2022 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT ... | 2D | Oct 27, 2022 |
| Oct 3, 2022 | C | DEFECT LETTER ISSUED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 2D | Oct 27, 2022 |
| Oct 3, 2022 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT ... | 2D | Oct 27, 2022 |
| Oct 3, 2022 | A | VIOLATION WILL BE REINSPECTED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 2D | Jan 6, 2023 |
| Oct 3, 2022 | C | NOV SENT OUT | § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURI... | 2D | Oct 27, 2022 |
| Oct 3, 2022 | A | VIOLATION WILL BE REINSPECTED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st DOOR FROM SOUTH AT W... | 2D | Jan 6, 2023 |
| Oct 3, 2022 | A | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 2D | Jan 6, 2023 |
| Oct 3, 2022 | A | VIOLATION WILL BE REINSPECTED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st CLOSET FROM SOUTH AT... | 2D | Jan 6, 2023 |
| Oct 3, 2022 | C | VIOLATION DISMISSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2D | Oct 29, 2022 |
| Sep 30, 2022 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH AT BATHTUB I... | 4C | Jan 3, 2023 |
| Sep 30, 2022 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK .... AT CEILING IN THE PRIVATE... | 4C | Nov 4, 2022 |
| Sep 30, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR .... AT CEILING IN ... | 4C | Nov 4, 2022 |
| Sep 30, 2022 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WASHBASIN CABINET IN THE BATHROOM LOCATED AT APT 4C, 4th ... | 4C | Jan 3, 2023 |
| Sep 30, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM ... | 4C | Nov 4, 2022 |
| Sep 30, 2022 | A | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ... INTERCOM LOCATED AT APT 4C, 4th STORY | 4C | Jan 3, 2023 |
| Sep 30, 2022 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT .. ALL WALLS AND CEILING IN ... | 4C | Jan 3, 2023 |
| Sep 30, 2022 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 50 SQ FT AT THE CE... | 4C | Oct 26, 2022 |
| Sep 28, 2022 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER SASH WINDOW AT FIRE ESCAPE IN THE 1st ROOM FROM EAST... | 3D | Oct 4, 2022 |
| Sep 28, 2022 | C | VIOLATION DISMISSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE EN... | 3D | Oct 12, 2022 |
| Sep 28, 2022 | B | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE F... | 3D | Nov 2, 2022 |
| Sep 28, 2022 | C | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE DRAIN PIPE AT SINK IN THE KITCHEN LOCATED AT ... | 3D | Oct 4, 2022 |
| Sep 28, 2022 | B | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING MECHANISM AT LOWER WINDOW SASH, 1ST WINDOW FROM THE... | 3D | Nov 2, 2022 |
| Sep 28, 2022 | B | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE HAND RAIL AT WEST WALL IN THE BATHROOM LOCATED AT APT 3D, 4th STORY, 2nd... | 3D | Nov 2, 2022 |
| Sep 28, 2022 | B | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE UPPER WINDOW SASH SPRING MECHANISM IN THE BATHROOM LOCATED... | 3D | Nov 2, 2022 |
| Sep 28, 2022 | C | VIOLATION WILL BE REINSPECTED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 4th STO... | 3D | Oct 24, 2022 |
| Sep 8, 2022 | A | VIOLATION WILL BE REINSPECTED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMTELY 2SQ.FT AT EAST WALL... | 2D | Dec 12, 2022 |
| Sep 6, 2022 | B | VIOLATION DISMISSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 3rd STORY,... | 2D | Oct 11, 2022 |
| Sep 6, 2022 | C | VIOLATION DISMISSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2D | Oct 2, 2022 |
| Sep 6, 2022 | B | VIOLATION DISMISSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2D | Oct 11, 2022 |