ECB violations
773 East 183 Street, Bronx • Block 03114 • Lot 0041
19 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 3, 2024 | 39533076L | RESOLVE | CLASS - 2 | OBSERVED CONSTRUCTION FENCE @ EXPOSURE 1 OF JOBSITE. WHEN REVIEWING DOCUMENTS ON DOB INTERNAL SYSTEMS IT WAS APPARENT... | $0 | $0 | Dec 20, 2024 |
| Mar 11, 2024 | 39526314M | RESOLVE | CLASS - 2 | 8 FLOOR CFS FLOOR FRAMING AND CONCRETE POUR OF SLAB INCOMPLETE, BC3308.6.1.1 STIPULATES FLOOR REACHES A HEIGHT OF SIX... | $2,500 | $0 | May 17, 2024 |
| Mar 11, 2024 | 39526315Y | RESOLVE | CLASS - 2 | OBSERVED MATERIAL AT PUBLIC STREET MISSING 4 FOOT BARRIER WITH HALF INCH NETTING ON TOP AS PERBC3307.4.7 CREATED HAZA... | $2,400 | $0 | May 17, 2024 |
| Feb 20, 2024 | 39525704N | RESOLVE | CLASS - 2 | DURING THE INSPECTION, COLD-FORMED STEEL WAS NOTED AS INSTALLED FROM THE FIRST TO THE SEVENTH FLOOR OF THE JOB SITE, ... | $1,280 | $0 | Feb 6, 2025 |
| Feb 20, 2024 | 39525703L | RESOLVE | CLASS - 2 | UPON INSPECTION, OBSERVED NO ROOF PROTECTION ON ADJACENT PROPERTIES @ EXPOSURES 2 AND 4, AS WELL AS NO OVERHEAD PROTE... | $1,280 | $0 | Feb 6, 2025 |
| Aug 31, 2023 | 39521280K | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF AN ACTIVE JOBSITE, I OBSERVED THAT THERE WAS NO JOBSITE FENCE AT EXPOSURE 4 WHICH IS CONTRAR... | $1,280 | $0 | Nov 17, 2023 |
| Jun 30, 2023 | 39518608H | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE. UPON REQUESTING SITE SAFETY PLAN NOTICE MISSING PAGES ON PLAN. SSP SHO... | $0 | $0 | Sep 15, 2023 |
| Jun 30, 2023 | 39518613M | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION, OBSERVED EXCAVATION APPROX. 7 FEET DEEP. NOTICE INADEQUATE GUARDRAIL SYSTEM AROUND EXCAVATION ... | $2,500 | $0 | Sep 15, 2023 |
| Jun 30, 2023 | 39518617J | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, OBSERVED SEVERAL UNCAP REBARS THROUGHOUT THE SITE ON EXCAVATION APPROX. 7 FEET DEEP. INADEQUAT... | $0 | $0 | Sep 15, 2023 |
| Jun 30, 2023 | 39518607X | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, OBSERVED ACTIVE JOB SITE CURRENTLY IN FOUNDATION PHASE. UPON REQUESTING SST TRAINING CONNECT I... | $625 | $0 | Sep 15, 2023 |
| Jun 30, 2023 | 39518615X | RESOLVE | CLASS - 2 | UPON REVIEWING SITE SAFETY PLAN NOTICE EGRESS PLAN NOT CONFORMING. SSP SHOWS SWING GATE GOING INTO THE SITE, AT TIME ... | $0 | $0 | Sep 15, 2023 |
| Apr 5, 2023 | 39514976N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN WATER DRAINAGE DURING EXCAVATION. 8 STORY NB AT EXCAVATION PHASE. I OBSERVED SITE WAS FULLY EXCAV... | $2,500 | $0 | Mar 8, 2024 |
| Jan 20, 2023 | 39511911Z | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION ON A NON-ACTIVE JOBSITE, I OBSERVED A CONSTRUCTION FENCE POORLY MAINTAINED. FOR INSTANCE, 1-MUL... | $0 | $0 | Mar 31, 2023 |
| Dec 21, 2022 | 39510664X | RESOLVE | CLASS - 2 | A PROPOSED 7 STORY NB ACTIVE SITE AT EXCAVATION PHASE. I OBSERVED UNSAFE STORAGE OF FLAMMABLE MATERIALS COMBUSTIBLE G... | $0 | $0 | Mar 3, 2023 |
| Dec 21, 2022 | 39510662M | RESOLVE | CLASS - 2 | 7 STORY NB ACTIVE SITE.I OBSERVED A RETAINING WALL 8 EXCAVATION PILES BETWEEN WALL IN PLACE EX2.ALSO OBSERVED ADJACEN... | $0 | $0 | Mar 3, 2023 |
| Dec 21, 2022 | 39510663Y | RESOLVE | CLASS - 2 | A 7 STORY NB AT EXCAVATION PHASE ACTIVE SITE. I OBSERVED CONSTRUCTION FENCE IN PLACE AT EXP#1,2,4. AT EXP#3 OBSERVED ... | $0 | $0 | Mar 3, 2023 |
| May 17, 2002 | 34327004N | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY BUILDING DEPARTMENT RECORDS. NOTED: IN CELLAR ERECTED ONE CLASS A APARTMENT 1 B... | $400 | $0 | Jul 5, 2002 |
| May 17, 2002 | 34327005P | RESOLVE | Non-Hazardous | WORK WITHOU A PERMIT. NORTED: ERECTED ONE CLASS A APARTMENT IN CELLAR 1-KITCHEN. REMEDY: OBTAIN PERMIT. | $0 | $0 | Aug 23, 2002 |
| May 9, 2002 | 34325467K | RESOLVE | Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY HPD RECORDS CELLAR AND FIRST STORY CONVERTED FROM ORDINERY USE BOTH CELLAR AND ... | $800 | $0 | Oct 4, 2002 |