ECB violations
2100-2110 Mohegan Avenue, Bronx • Block 03124 • Lot 0001
125 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 25, 2026 | 35668532Z | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: MINOR MASONRY BRICK CRACKING IN FACADES ALONG EAST 181 ... | $1,250 | $1,250 | Jan 15, 2027 |
| May 8, 2026 | 39187886Y | ACTIVE | CLASS - 2 | I FOUND A ROCK MILL STEAM BOILER LEAKING FROM THE CHAMBER/ 1/2INCH COPPER TUBING 4 FEET LONG USE AS GAS IGNITION/ U R... | $1,280 | $1,280 | Aug 7, 2026 |
| May 7, 2026 | 39187701Z | RESOLVE | CLASS - 1 | CLASS 1 (CU):FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-... | $1,280 | $1,280 | Aug 7, 2026 |
| Apr 7, 2026 | 39183581P | ACTIVE | CLASS - 2 | CLAS 2 ITEMS: IN-CAR COMMUNICATION IS NOT CONNECTED TO A CONTINUOUSLY STAFFED LOCATION, AS REQUIRED BY NYC BUILDING C... | $655 | $655 | Jul 17, 2026 |
| Jan 16, 2026 | 39174258K | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. CLASS 2 ITEMS: 1) EXCESSIVE SIDE-TO-SIDE MOVEMENT ON THE CAR, ... | $3,125 | $3,125 | Apr 3, 2026 |
| Jan 16, 2026 | 39174259M | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. CLASS 2 ITEMS: 1) MOTOR ROOM LIGHT INOPERATIVE, REPAIR. 2) MOT... | $3,125 | $3,125 | Apr 3, 2026 |
| Jul 2, 2025 | 39152600J | ACTIVE | CLASS - 2 | ROCKMILLS MODEL MP125. MISSING DAWGS ON FRONT AND BACK BOILER DOORS. MISSING AIR GAP AND DISCHARGE PIPE ON BACK FLOW ... | $6,250 | $6,250 | Sep 5, 2025 |
| Apr 22, 2025 | 39145657P | ACTIVE | CLASS - 1 | RESPONDING, TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT-OF-SERVICE AS PER 1RCNY 11-02... | $12,500 | $12,500 | Jul 18, 2025 |
| Apr 1, 2025 | 39143468R | ACTIVE | CLASS - 2 | RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION, ONE OF TWO DEVICE IS FOUND TO BE OUT-0F- SERVICE. AS PER 1RC... | $3,125 | $3,125 | Jun 6, 2025 |
| Nov 20, 2024 | 39130795L | ACTIVE | CLASS - 2 | IN APT 1-B, IN BATHROOM, WATER SEEPAGE HAS CEILING PEELING AND CRACK APPEARS,ALSO MOLD AT BASE BEHIND BOWL., REPAIR A... | $3,125 | $3,125 | Jan 31, 2025 |
| Sep 16, 2024 | 39125041Z | ACTIVE | CLASS - 1 | OBSERVED EXTERIOR BALCONIES UNDERSIDE INSTATE OF DISREPAIR CONDITIONS WITH SPALLING CONCRETE, ROTTEN & EXPOSED REBARS... | $6,250 | $6,250 | Nov 29, 2024 |
| Jun 8, 2024 | 39116336L | ACTIVE | CLASS - 1 | AT TIME OF INSPECTION I OBSERVE ON 3L CONCRETE SPALLING ON BALCONY 4L . REBAR IS EXPOSED ON MULTIPLE AREAS AND IN NEE... | $6,250 | $6,250 | Aug 16, 2024 |
| Apr 10, 2024 | 39111311M | ACTIVE | CLASS - 2 | TUBES LEAKING AND HOLES IN CEILING | $3,125 | $3,125 | Jun 21, 2024 |
| Dec 28, 2023 | 39102343M | ACTIVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED A VERTICAL CRACK APPROX. 5'-0" LONG ON 1ST FLOOR EXTERIOR BRICK WALL BY THE WINDOW. AL... | $6,250 | $6,250 | Mar 15, 2024 |
| Jun 15, 2022 | 39064139K | ACTIVE | CLASS - 2 | B254 ASPER DOB RECORDS PERMIT # 200301020 HAS NOT BEEN SIGNED OFF THEREFORE BOILER IS UNREGISTERED.REGISTER BOILER AN... | $3,125 | $3,125 | Aug 5, 2022 |
| Jan 26, 2021 | 39035403H | RESOLVE | CLASS - 2 | NO DRIP ON BACKFLOW-CORROSION ON WC BLOWDOWN/GAS PIPE-LUGZ MISSING FRONT BLR. DOOR-SAFETY VALVE DISCHARGE NOT SUPPORT... | $0 | $0 | Mar 19, 2021 |
| Oct 19, 2020 | 39030626M | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; INSTALL... | $1,250 | $0 | Dec 4, 2020 |
| Oct 19, 2020 | 39030631R | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; INSTALL... | $1,250 | $0 | Dec 4, 2020 |
| Sep 23, 2020 | 39029105Z | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; INSTALL... | $1,250 | $0 | Nov 20, 2020 |
| Sep 23, 2020 | 39029106K | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; INSTALL... | $1,250 | $0 | Nov 20, 2020 |
| Jun 11, 2020 | 39023827N | RESOLVE | CLASS - 1 | UPON INSPECTION THE DEVICE IS FOUND TO BE OUT-OF-SERVICE. REMEDY: RESTORE DEVICE TO SERVICE AND CONTACT NYCDOB BY EMA... | $1,250 | $0 | Nov 6, 2020 |
| Jan 16, 2020 | 38272950J | RESOLVE | CLASS - 2 | 5J1, 16J1, 66Q3, 59U7, 70O2: 5-J-1 16-J-1 66-Q-3 59-U-7 70-O-2 | $0 | $0 | Mar 6, 2020 |
| Aug 27, 2019 | 38271365Y | RESOLVE | CLASS - 2 | R/C(26-B-11, 26-D-06, 39-Y-02),56-Y-13, 98-BB-05, 59-BB-05, 66-D-11, 57-B-11, 59-M-07, 52-U-07, 53-U-07, 71-X-10, 32-... | $1,563 | $0 | Dec 13, 2019 |
| Jun 20, 2019 | 38270250J | RESOLVE | CLASS - 1 | 97X17 REPAIR AND RESTORE TO SERVICE IMMEDIATELY AND NOTIFY NYCDOB FORREINSPECTION. | $1,250 | $0 | Aug 16, 2019 |
| Apr 29, 2019 | 38269501R | RESOLVE | CLASS - 1 | (CEASE USE)05.A.10,17.B.10,26.B.11,26.D.06,39.Y.02,52.U.07,97.O.02,21.M.07,68.B.07,68.M.07,59.B.07,40.O.02,59.M.07,56... | $1,280 | $0 | Jul 5, 2019 |
| Feb 24, 2019 | 38268294Z | RESOLVE | CLASS - 1 | 97X17 REPAIR AND CONTACT NYCDOB NOTIFYING OF REPAIR SERVICE COMPLETEDAND DEVICE RETURN TO SERVICE. | $1,250 | $0 | Apr 19, 2019 |
| Feb 22, 2019 | 38266443Y | RESOLVE | CLASS - 2 | 28-3047 100R7-THE OWNER SHALL HAVE A MAINTENANCE CONTRACT WITH AN APPROVED PERFORM ELEVATOR REPAIR WORK AND MAINTENAN... | $0 | $0 | Apr 19, 2019 |
| Feb 19, 2019 | 38268065P | RESOLVE | CLASS - 1 | (CEASE USE)05.A.10,(C/U)42.G.11,25.M.07,39.O.02,67.X.10,68.B.07,70.O.02=(05,A,10)CEASE USE ITEM DOOR ZONE RESTRICTOR ... | $1,250 | $0 | Apr 5, 2019 |
| Dec 17, 2018 | 38267021Z | RESOLVE | CLASS - 1 | CEASE USE.57M07,70O02,68B01,C/U 06B07.57-M-07=REMEDY PROVIDE FIRE EXTINGUISHER IN MOTOR ROOM.70-0-02=REMEDY CLEAN HOI... | $1,250 | $0 | Mar 22, 2019 |
| Nov 14, 2018 | 38265924K | RESOLVE | CLASS - 1 | 97X17 RMDY: RESTORE TO SERVICE IMMEDIATELY AND NOTIFY NYCDOB THE DEVICE HAS BEEN RETURNED TO SERVICE. CALL 212-393-24... | $1,250 | $0 | Jan 7, 2019 |
| Aug 28, 2018 | 38264976H | RESOLVE | CLASS - 1 | 05A10,68B07,67X10,32H11,57BB07,59BB07-05A10)CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/DISABLED AND ... | $1,250 | $0 | Oct 19, 2018 |
| Oct 2, 2017 | 38258455L | RESOLVE | CLASS - 1 | 6B10,39B10,66L10,68M7,68M7,61B7-6B10)DOOR POSITION MONITORING DID NOT WORK. 39B10)TOP OF CAR EXHAUST FAN NOT WORKING.... | $1,000 | $0 | Nov 28, 2017 |
| Aug 3, 2017 | 37005895N | RESOLVE | CLASS - 2 | INSTALL SEAL AND SECURE GOVERNOR | $0 | $0 | Sep 29, 2017 |
| Feb 21, 2017 | 38252187R | RESOLVE | CLASS - 2 | 42M07,61D11,97O02. 42M07-DOOR MONITOR MISSING; 61D11-DISCONNECT BOSC OPEN WHILE WHILE ENERGIZED. PROVIDE HEAVY DUTY B... | $250 | $0 | Apr 7, 2017 |
| Feb 21, 2017 | 38252186P | RESOLVE | CLASS - 2 | 56Q07,42M07,97O02,61D11. 56Q07-PROVIDE CABLE GUARD; 42M07-DOOR MONIT OR MISSING; 97O02-DIRTY DEVBICE; 61D11-DISCONNEC... | $250 | $0 | Apr 7, 2017 |
| Aug 2, 2016 | 38244685J | RESOLVE | CLASS - 1 | 97X10.RESTORE TO SERVICE IMMEDIATELY. | $2,500 | $0 | Sep 23, 2016 |
| Jul 27, 2016 | 38244393H | RESOLVE | CLASS - 1 | 97X10.FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER,SERVICE EQUIPMENT ELEVATOR AS PER BC3001.2&27-987.DOB RECORDS... | $10,000 | $0 | Sep 16, 2016 |
| Jul 14, 2016 | 38244146K | RESOLVE | CLASS - 1 | 97X10. ENTIRE DEVICE RETURN TO SERVICE IMMEDIATELY. | $5,000 | $0 | Sep 2, 2016 |
| Jul 14, 2016 | 38244145Z | RESOLVE | CLASS - 1 | 97X10. ENTIRE DEVICE RESTORE TO SERVICE IMMEDIATELY. | $5,000 | $0 | Sep 2, 2016 |
| Jul 14, 2016 | 38244144R | RESOLVE | CLASS - 1 | 02X10,05B01,44H11,52H11,71M07. (02X)REPAIR & RESTORE PHONE SERVICE. (05B)ADJUST DOOR RESTRICTOR FOR PROPER OPERATION.... | $1,000 | $0 | Sep 2, 2016 |
| Jul 6, 2016 | 38241844Y | RESOLVE | CLASS - 1 | 76L10,73L10,56Q03,34O02,70Z09.76 DEFECTIVE CAR SAFETY MUST REPAIR &ADJUST;73 DEFECTIVE CAR RAILS BY 2ND FLR MUST REPA... | $5,000 | $0 | Sep 2, 2016 |
| Jun 7, 2016 | 32076850X | RESOLVE | CLASS - 2 | WATER LEAKING FORM BACK REAR DOOR ON BOILER. (CLEAN OUT DOOR) | $0 | $0 | Jul 29, 2016 |
| Apr 12, 2016 | 38242179H | RESOLVE | CLASS - 2 | 97X10-RESTORE ENTIRE DEVICE TO SERVICE.DOB RECORDS SHOW DEVICE 2P5079 AS ACTIVE, BUT UPON INSPECTION ELEVATOR WAS FOU... | $500 | $0 | Sep 9, 2016 |
| Mar 22, 2016 | 38241226R | RESOLVE | CLASS - 2 | 02X10,12L10,39O02,41I10,60L10,59M05. 02-IN CAR COMMUNICATION INOPERAT IVE MUST REPAIR; 12-CAR LIGHTING DEFECTIVE MUST... | $500 | $0 | Jul 29, 2016 |
| Mar 18, 2016 | 32075983P | RESOLVE | CLASS - 2 | 11CM16,21A,32A,42,44,50A,50B,50C. 50A-NEED TO SEAL REAR DOOR OF BOILER; 50B-NEED TO CLEAN OIL FROM FLOOR AT PUMP; 50C... | $0 | $0 | May 6, 2016 |
| May 4, 2015 | 38236154K | RESOLVE | CLASS - 1 | 97X10 REPAIR ELEVATOR AND RETURN TO SERVICE CALL FOR INSPECTION BEFORERETURNING TO SERVICE. | $5,000 | $0 | Jun 19, 2015 |
| May 4, 2015 | 38236152R | RESOLVE | CLASS - 2 | 70O02,70Z09,71X10,39O02,39X10,99U05,67X10,32H10,68M07. 70-REMOVE WATERAND CLEAN PIT; 39X10-WORK LIGHT TOP OF CAR; 67-... | $2,500 | $0 | Sep 4, 2015 |
| Dec 1, 2014 | 38233988N | RESOLVE | CLASS - 1 | 97X10 REPAIR ELEVATOR AND RETURN TO SERVICE,CALL FOR INSPECTION BEFORERETURNING TO SERVICE. | $10,000 | $0 | Jan 16, 2015 |
| Nov 24, 2014 | 38233869K | RESOLVE | CLASS - 1 | 97X10 ENTIRE DEVICE OUT OF SERVICE FOR A SERIOUS AMOUNT OF TIME CAUS ING A HAZARDOUS CONDITION AND A HARDSHIP TO TENA... | $5,000 | $0 | Jan 16, 2015 |
| Nov 24, 2014 | 38233870H | RESOLVE | CLASS - 1 | 44H08,52H11,42N11,97X10. 44-WORN TRACTION SHEAVE REGROOVE; 52-WORN HOIST ROPES MUST REPLACE; 42-REPLACE JUMPED FUSES ... | $5,000 | $0 | Jan 16, 2015 |