ECB violations
984 Bronx Park South, Bronx • Block 03134 • Lot 0014
28 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 21, 2025 | 39157948N | RESOLVE | CLASS - 1 | RESPONDING, TO A COMPLAINT, UPON INSPECTION, CEASE USE ITEMS WAS FOUND ON DEVICE, 1/ CAR DOOR SAFETY EDGE NOT WORKING... | $1,250 | $1,250 | Oct 31, 2025 |
| Dec 23, 2024 | 39133626Y | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED DAMAGED BRICKS,SPALLING AND MISSING MORTAR JOINTS AND STEP CRACKS AT PARAPET LEVEL INC... | $1,250 | $0 | Apr 25, 2025 |
| Aug 21, 2020 | 39027343P | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $0 | Jan 8, 2021 |
| Dec 22, 2016 | 32086583J | RESOLVE | CLASS - 2 | B254,32A,40,50,50A,15. 50-NEED TO FIX BOTH SIDE OF BOILER FOR JACKET ING; 50A- NEED TO CLEAN BOILER ROOM OF ALL DEBRIS. | $500 | $0 | Feb 17, 2017 |
| Sep 28, 2016 | 38246211R | RESOLVE | CLASS - 1 | 5A10,40O02,70O02,68B07. (5A10)CAB DOOR RESTRICTOR HAS BEEN TAMPERED W/ (REPAIR). | $1,000 | $0 | Nov 18, 2016 |
| Sep 28, 2016 | 38246210P | RESOLVE | CLASS - 1 | CEASE USE. 5A10,97D10,5M11. (5A10)CAB DOOR RESTRICTOR HAS BEEN TAMPERED W/(REPAIR). (97D10)ELEVATOR STOP & LEAVES THE... | $1,000 | $0 | Nov 18, 2016 |
| Aug 29, 2016 | 35182222N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:LACK OF A SYSTEMOF AUTOMATIC SPRINKLRS WHERE REQUIRED PER BC 90... | $1,000 | $0 | Oct 21, 2016 |
| May 14, 2016 | 38242875L | RESOLVE | CLASS - 2 | 39L10,56Y13,100BB11,98BB11,98BB05,99BB05,42D06,39O02,35Q03,16L10,37O02,07M07,67M07,16H11,17H11,16R09,70O02,71O02,12L1... | $250 | $0 | Jul 1, 2016 |
| Jan 25, 2016 | 38239586H | RESOLVE | CLASS - 2 | 70-O-02,71-M-11,16-M-11,40-P-07:70-O-02-CLEAN PIT/71-M-11-REPLACE PIT LAMP/16-M-11-REPLACE (BRDEN)-LOBBY (H/DR.CLOSER... | $2,500 | $0 | Mar 18, 2016 |
| Jan 25, 2016 | 38239585X | RESOLVE | CLASS - 2 | 71-M-07,70-O-02,15-M-07,40-O-07,02-M-07:71-M-07-PROVIDE PIT LIGHT/70-O-02-CLEAN PIT/15-M-07-PROVIDE CAR-CERT FRAME/40... | $2,500 | $0 | Mar 18, 2016 |
| Feb 9, 2012 | 34940299P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.USE OF PROHIBITED DOOR &/OR HARDWARE PER BC1008.1.8;27-371(J).NOTED... | $1,000 | $0 | May 24, 2012 |
| Dec 20, 2011 | 38219593H | RESOLVE | CLASS - 2 | 05J10,08#10: 08;REPAIR TRANSITION AS ELEVATOR COMES INTO FLOOR STOPS (ELIMINATE HARD STOP). | $0 | $0 | Feb 3, 2012 |
| Dec 20, 2011 | 38219594J | RESOLVE | CLASS - 2 | 03Q03,32H10,24X10,15I09,08M10: 03;WORKING FAN HAS NO COVER. 24;REBUILDINDICATOR. 08;LOBBY FLOOR FACIA MISSING. | $0 | $0 | Feb 3, 2012 |
| Apr 26, 2010 | 38209813L | RESOLVE | CLASS - 2 | 8V1,16H11,39D6,41T7,42G11,42B1,52B7,60Q3,69M7,71X10,78H10,53B14,100X1016H- 6TH FL HOISTWAY DOOR CLOSER. 39D- STEADY P... | $500 | $0 | Oct 8, 2010 |
| Aug 31, 2009 | 32066906R | RESOLVE | CLASS - 2 | B254 10A.50A.50B.50C.50D.50E.50F.50G50A RUBBER GASKET ON COIL PLATE CORRODED AND LEAKING 50B BOILER JACKETS MISSING 5... | $250 | $0 | Nov 20, 2009 |
| Aug 10, 2009 | 38205516R | RESOLVE | CLASS - 2 | 03X10.24X10.41D6.60X10.39O2.97L1.03X10 CAR ENCLOSURE CEILING FAN 24X10 IN LOBBY CAR POSITION INDIACTOR 97L1 ADJUST TR... | $250 | $0 | Oct 2, 2009 |
| Jul 30, 2009 | 38204936Z | RESOLVE | CLASS - 1 | 97X10.97X10 ONLY ELEVATOR IN BLDG SECTION OUT OF SERVICE THEREBY CREATING CONDITION DANGEROUS TO HUMAN LIFE REPAIR IM... | $1,000 | $0 | Oct 9, 2009 |
| Jul 13, 2009 | 38204833X | RESOLVE | CLASS - 1 | 97X1097X17. 97X10 SINGLE ELEVATOR IN BLDG SECTION NOT IN SERVICE REPAIR IMMEDIATELY CALL DOB ELEVATOR UNIT FOR REINSP... | $1,000 | $0 | May 19, 2010 |
| Jun 26, 2009 | 38204362Z | RESOLVE | CLASS - 1 | 97R* 97R*-UNLAWFUL ACT FAILURE TO COMPLY W/ COMMS ORDER SET FORM IN NOV #38204353R BY CONTINUED USING DEVICE AFTER CE... | $0 | $0 | May 14, 2010 |
| Jun 22, 2009 | 38204353R | RESOLVE | CLASS - 1 | CU58F10 70O02 39O02 98BB05 60B07 16H07 56Y13 56O02 CU58F10-THE HOIST MACHINE HAS BAD BACK LASH ELEVATOR BOUNCES AND J... | $1,000 | $0 | May 14, 2010 |
| Sep 19, 2007 | 38169803Y | RESOLVE | Non-Hazardous | 2X10,8U1,9I10,34X10,31H10,41D6,84#10. 41 PROPERLY SECURED PARTS TO CONTROLER PANEL. 84- CAR HAVE A HARD STOP, REPAIR.... | $350 | $0 | Feb 15, 2008 |
| Sep 19, 2007 | 38169802M | RESOLVE | Non-Hazardous | 2I10/41D6/84I11/16M7/.2-CAR LIGHTS GO OUT WHEN ALARM BUTTON IS PRESSEDPROPERLY WIRE ALARM BUTTON THEN WORK WITH STOP ... | $350 | $0 | Feb 15, 2008 |
| May 22, 2007 | 32053678L | RESOLVE | Non-Hazardous | B4A/10A/32A/34A/.50-SAFETY CONTROLS MOUNTED ON 1/4"PIPING. | $180 | $0 | Nov 2, 2007 |
| Apr 16, 2007 | 34568327P | RESOLVE | Hazardous | FIRE EXIT DOOR TOTAL OBSTRUCTION. EXTERIOR FIRE CORRIDOR DOOR PADLOCKED. REMEDY: REMOVE OBSTRUCTION. | $480 | $0 | Aug 3, 2007 |
| Jun 24, 2003 | 38140060N | RESOLVE | Non-Hazardous | 59X10 40T07 38Y02 33O02 66O02 10H10 16B10 #16-HOIST DOOR DEFECTS LOOSE | $180 | $0 | Oct 3, 2003 |
| Oct 16, 1999 | 38091233Y | RESOLVE | Non-Hazardous | 25B,57O,35P,75U,11M,14M,74M. PROVIDE GUARDS, REPLACE ALL COVER TOP OF CAR. | $2,500 | $0 | Dec 10, 1999 |
| Mar 24, 1998 | 38071710J | RESOLVE | Non-Hazardous | 40M14,3X11,63B15,55X11. 3-FAN. | $0 | $0 | May 8, 1998 |
| Mar 24, 1998 | 38071709M | RESOLVE | Non-Hazardous | 54L11,5X11,75U5,3X11,11B12,21X11,57O2. 5-DOORS DO NOT OPEN AT 5TH FL.3-FAN. | $350 | $0 | Sep 25, 1998 |