Maintenance code violations
2085 Webster Avenue, Bronx • Block 03143 • Lot 0132
1,074 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Dec 27, 2018 | B | VIOLATION CLOSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASING IN THE BATHROOM LOCATED AT AP... | 5E | Jan 31, 2019 |
| Dec 26, 2018 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WATER CLOSET COVER IN THE BATHROOM LOCATED AT APT 2W, 2nd STORY, 1... | 2W | Jan 30, 2019 |
| Dec 26, 2018 | B | VIOLATION DISMISSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT THE WASH BASIN IN THE BATHROOM LOCATED AT... | 4E | Jan 30, 2019 |
| Dec 26, 2018 | B | VIOLATION DISMISSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASH BASIN WASTE LINE IN THE BATHROOM LOCATED AT APT ... | 4E | Jan 30, 2019 |
| Dec 26, 2018 | B | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE BATHROOM LOCATE... | 4E | Jan 30, 2019 |
| Dec 26, 2018 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WEST WA... | 4E | Jan 30, 2019 |
| Dec 26, 2018 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN THE KI... | 4E | Jan 30, 2019 |
| Dec 26, 2018 | B | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT SOUTH AND WEST WALL APPROX... | 4E | Jan 30, 2019 |
| Dec 26, 2018 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEILING AND WEST WALL WITH FIRE RETA... | — | Mar 31, 2019 |
| Dec 26, 2018 | C | VIOLATION DISMISSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 4E | Jan 23, 2019 |
| Dec 26, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER EXCEEDING 130F READING 140F IN T... | 4E | Jan 3, 2019 |
| Dec 26, 2018 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT... | 4E | Jan 30, 2019 |
| Dec 26, 2018 | B | VIOLATION DISMISSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATH TUB IN THE BATHROOM LOCATED AT APT 4E, 4th STORY... | 4E | Jan 30, 2019 |
| Dec 24, 2018 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING SLIDE BOLT WITH EYE CAPABLE OF BEING PADLOCKED INSTALLED AT GAT... | — | Jan 28, 2019 |
| Dec 20, 2018 | A | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT THE SINK IN THE KITCHEN LOCATED AT APT 5E,... | 5E | Mar 25, 2019 |
| Dec 20, 2018 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STOR... | 5E | Jan 24, 2019 |
| Dec 20, 2018 | A | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROX. 2 SQ.FT. AT THE WEST ... | 5E | Mar 25, 2019 |
| Dec 20, 2018 | C | VIOLATION CLOSED | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET .. IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, APARTME... | 5E | Dec 28, 2018 |
| Dec 20, 2018 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 5E | Jan 24, 2019 |
| Dec 20, 2018 | B | VIOLATION DISMISSED | § 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 4E, 4th ST... | 4E | Jan 24, 2019 |
| Dec 18, 2018 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM GATE AT BASEMENT LOCKED AT BOILER ROOM | — | Dec 26, 2018 |
| Dec 18, 2018 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, ... | 5E | Dec 18, 2018 |
| Dec 18, 2018 | C | VIOLATION CLOSED | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4t... | 4E | Dec 18, 2018 |
| Dec 18, 2018 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW LOWER SASH IN THE 1st ROOM FROM EAST LOCATED AT AP... | 4E | Mar 23, 2019 |
| Dec 18, 2018 | C | VIOLATION CLOSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY | 4E | Dec 18, 2018 |
| Dec 17, 2018 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 2W | Dec 25, 2018 |
| Dec 7, 2018 | B | VIOLATION CLOSED | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... 6 SQ/FT AT WEST WALL IN THE B... | 5E | Jan 11, 2019 |
| Dec 7, 2018 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... | 5E | Jan 4, 2019 |
| Dec 7, 2018 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 5E | Mar 12, 2019 |
| Dec 7, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE THE CEILING IN THE 3rd ROOM FROM EAST AT SOUTH LOCA... | 5E | Jan 11, 2019 |
| Dec 7, 2018 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STOR... | 5E | Jan 11, 2019 |
| Dec 7, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD DOOR AND KNOB IN THE 1st ROOM FROM EAST AT CENTER LO... | 5E | Jan 11, 2019 |
| Dec 7, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BASE CABINET WOOD DOOR AT SINK IN THE KITCHEN LOCATED AT APT 5E, 5th ... | 5E | Jan 11, 2019 |
| Dec 7, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE 1st WINDOW FRAM... | 5E | Jan 11, 2019 |
| Dec 7, 2018 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1s... | 5E | Jan 11, 2019 |
| Dec 7, 2018 | B | VIOLATION CLOSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY,... | 5E | Jan 11, 2019 |
| Dec 7, 2018 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE AT SINK IN THE KITCHEN LOCATED AT APT 5E, 5th ... | 5E | Jan 11, 2019 |
| Dec 7, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR KNOB IN CLOSET DOOR AT SOUTH IN THE 1st ROOM FROM EAS... | 5E | Jan 11, 2019 |
| Dec 6, 2018 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RADIATOR FROM NORTH AT EAST WALL IN THE KI... | 5E | Mar 11, 2019 |
| Dec 6, 2018 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE 1st RADIATOR FROM EAST AT SOUTH WALL IN THE 2n... | 5E | Mar 11, 2019 |
| Nov 19, 2018 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM NORT... | 4E | Dec 24, 2018 |
| Nov 19, 2018 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 4E, 4th STORY, 1st... | 4E | Dec 24, 2018 |
| Nov 16, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONSTRUCTION MATERIALS AND HOUSEHOLD FURNITURE AT P... | — | Dec 21, 2018 |
| Nov 16, 2018 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM NO... | 5E | Dec 21, 2018 |
| Nov 16, 2018 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | 5E | Dec 14, 2018 |
| Nov 16, 2018 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... | 5E | Dec 14, 2018 |
| Nov 13, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE 3RD. . MARBLE TREAD UP FROM BOTTOM AT PUBLIC HALL STAIRS,... | — | Nov 21, 2018 |
| Nov 13, 2018 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | — | Nov 21, 2018 |
| Nov 13, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE 6TH., AND 7TH., MARBLE TREADS UP FROM BOTTOM AT PUBLIC HA... | — | Nov 21, 2018 |
| Nov 13, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE 8TH. MARBLE TREAD UP FROM BOTTOM AT PUBLIC HALL STAIRS, 2... | — | Nov 21, 2018 |