ECB violations
340-356 East 184 Street, Bronx • Block 03143 • Lot 0271
79 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 5, 2026 | 39199223L | ACTIVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED A VIOLATING, FAILURE TO MAINTAIN, CONDITION FOR APPROXIMATELY 8 A/C UNITS PROTRUDING F... | $1,250 | $1,250 | Oct 16, 2026 |
| Feb 8, 2022 | 35639927K | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE PEDESTRIAN PROTECTION.ATO MY INSP OF OCCUPIED 10ATYB W/SWS ACTIVE PERMIT.SWS DOESNT MEET CODE,FAIL... | $0 | $0 | Nov 18, 2022 |
| Mar 30, 2021 | 35551826P | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE SIDEWALK SHED INFORMATION PANEL.AT TIME OF MY INSPECTION OF A OCCUPIED 7 STORY BLDG.I OBSERVED A S... | $0 | $0 | Jun 18, 2021 |
| Feb 13, 2020 | 37018117J | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Oct 16, 2020 |
| Dec 19, 2018 | 38267036L | RESOLVE | CLASS - 1 | (C/U)(R/C)42.B.10,(C/U)(R/C)59.B.10,(R/C)67.X.10,41.I.11,56.Y.13.40.O.02,57.BB.11,53.U.07,09.I.10,39.X.10,26.D.06,70.... | $1,250 | $0 | Feb 15, 2019 |
| Dec 22, 2017 | 38259315Y | RESOLVE | CLASS - 1 | 05X05, 39X11, 77X11, 59E01, 59X10, 59BB07, 02X10, 70O02 (05)TURN ON DOOR POSITION MONITOR OR INSTALL PROPER CHIP FOR ... | $1,000 | $0 | Feb 16, 2018 |
| Jul 24, 2017 | 38257052M | RESOLVE | CLASS - 1 | 05A10,02L10,40M07. 05A10-DOOR ZONE RESTRICTOR ALTERED.THIS IS A SAFETY DEVICE TO ENSURE PASSENGERS SAFETY.PLEASE REPA... | $1,000 | $0 | Sep 19, 2017 |
| Jul 12, 2017 | 38256367M | RESOLVE | CLASS - 1 | 97X17. THE ONLY ELEVATOR IN BLDG IS OUT OF SERVICE CREATING A HAZARDOUS CONDITION PLEASE RESTORE BACK TO SERVICE IMME... | $1,000 | $0 | Sep 15, 2017 |
| Feb 16, 2017 | 35173990L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG NORTH ELEVATION,EXP#1(FRONT OF BLDG)OBSERVED CRACKS,DETERIORATING & IN MASONRY FACA... | $500 | $0 | Jun 30, 2017 |
| Feb 16, 2017 | 35173991N | RESOLVE | CLASS - 1 | FAILURE TO TAKE & PROVIDED SAFETY MEASURES(SIDEWALK SHED,NETTING,ETC)WHERE REQUIRED TO FULLY PROTECTION & SECURE PUBL... | $2,400 | $0 | Jun 30, 2017 |
| Oct 12, 2016 | 38250502Z | RESOLVE | CLASS - 1 | 05X10,59M07,67X10,57BB11. 05-DOOR RESTRICTOR NOT WORKING PROPERLY; 59-NO BRAKE MAINTENANCE. | $1,000 | $0 | Dec 23, 2016 |
| Aug 30, 2016 | 38246391N | RESOLVE | CLASS - 1 | 05L10,05E1,59M7,67L10,70O2. DOOR RESTRICTOR DEFECTIVE REPAIR; CAR DOOR RUBBING ADJUST MACHINE BRAKE MAINTENANCE TAG M... | $1,000 | $0 | Jun 30, 2017 |
| Jul 19, 2016 | 38244330K | RESOLVE | CLASS - 2 | 02X10,59U15,68B04,70O02. 02-OUTSIDE COMMUNICATION CAR PHONE INOPERATIVE REPAIR; 59-MACHINE BRAKE DEVICE NOT TAGGED PE... | $500 | $0 | Sep 2, 2016 |
| Jul 12, 2016 | 35174445K | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE SAFETY MEASURES SUCH AS SIDEWALK SHED FENCE ETC TO PROTECT PUBLIC FROM UNSAFE FACADES AS PER 1RCNY... | $2,400 | $0 | Sep 2, 2016 |
| Jul 12, 2016 | 35174446M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES. NOTED: AT TIME OF INSPECTION (1) AT EXP#1(FRONT COURTYARD)BULGED/DISL... | $500 | $0 | Sep 2, 2016 |
| Feb 5, 2016 | 36024094K | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 6 REPORT TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS DE... | $4,000 | $0 | Jun 3, 2016 |
| Sep 4, 2015 | 35133604H | RESOLVE | CLASS - 1 | FAILURE TO TAKE & PROVIDE SAEFTY MEASURE SUCH AS SIDEWALK SHED,FENCE ETC. TO PROTECT PUBLIC WHERE REQUIRED,FROM DOCUM... | $2,400 | $0 | Oct 30, 2015 |
| Aug 12, 2014 | 35025847Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT 5TH STORY,APT 5F LOCATED AT SOUTH-WEST SECTION OF BLDG. ... | $1,000 | $0 | Oct 24, 2014 |
| Apr 2, 2014 | 35091098L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES.NOTED:@ RUBBLE STONE FOUNDATION WALL ADJACENT TO 358 E 184 ST,VARIOUS... | $0 | $0 | May 30, 2014 |
| May 11, 2011 | 38216426R | RESOLVE | CLASS - 2 | 03B10,41D06,57E10,60M07,20M07,11B10,70M07,70O02,39O02.(03B10)REMOVE ALL SHARP EDGES ON METAL SKIN OF CAB ENCLOSURE.(4... | $2,500 | $0 | Jul 1, 2011 |
| Apr 15, 2011 | 36016582J | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXT... | $1,000 | $0 | Aug 19, 2011 |
| Jul 12, 2010 | 36014120X | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS:PERIODIC INSPECTION OF EXTE... | $8,000 | $0 | Oct 15, 2010 |
| Nov 30, 2009 | 34823878R | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO CORRECT VIO #34786873HFOR WORK W/O A PERMIT ALTERED STORES TO CREATE ... | $2,400 | $0 | Feb 16, 2011 |
| Nov 27, 2009 | 36010609N | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS PERIODIC INSP OF EXTERIOR... | $800 | $0 | Feb 19, 2010 |
| Jul 7, 2009 | 34786873H | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. NOTED: AT BASEMENT LEVEL, EAST SECTION FROM BLDG, REMOVED STORE FRONTS OF 4 STORES AND ERECTED BRI... | $1,600 | $0 | Feb 7, 2011 |
| Jul 7, 2009 | 34786874J | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O OR BLDG DEPT RECORDS. C/O #14446 DTD 7.1.1954 INDICATES PREMISES TO BE LEGA... | $2,400 | $0 | Feb 11, 2011 |
| Apr 30, 2009 | 34748369L | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR DOB RECORDS. BASEMENT APT IS NOW BEING USE SINGLE ROOM OCCUPANCY ... | $2,400 | $0 | Oct 19, 2009 |
| Jan 30, 2009 | 36008262K | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... | $800 | $0 | Dec 7, 2009 |
| Jul 11, 2008 | 32060204P | RESOLVE | CLASS - 3 | B354,16,32A,42,50A,50B,28.301.1,40. 50A NO SWING CHECK ON BOILER MAKE UP WATER LINE. 50B DOMESTIC RELIEF VALVE NOT PI... | $200 | $0 | Sep 5, 2008 |
| Feb 28, 2006 | 34549358Y | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS: PERIODIC INSP. OF EXTERIOR WALLS & ... | $1,750 | $0 | May 5, 2006 |
| Dec 16, 2005 | 34548958N | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR ... | $0 | $0 | Aug 4, 2006 |
| Feb 23, 2004 | 38145453R | RESOLVE | Non-Hazardous | 16L10/16R10/20A11/26U5/39Y2/40I10/41G11/41M7/55Y2/56L9/57B7/83U15/85U5/86U5/16L10=SLAMS=ALL FLS BUT 1ST FL.16R10= HAN... | $0 | $0 | Oct 22, 2004 |
| Dec 2, 2002 | 38135463L | RESOLVE | Non-Hazardous | 79O02-37T16-55X11-52YU14-37Q03-31O02-18I12-16L11-80K10-52#09-08V01. 37-CITY ID 37-PROVIDE COVER IN FRONT OF GOV (BIG ... | $2,500 | $0 | Jan 17, 2003 |
| Mar 6, 2002 | 38121264L | RESOLVE | Non-Hazardous | 02L11/14I11/36B11/35R08/50J11/10Q07/22D06/03O02/08J01/05I11/28H01/62K11/31Q07/57O02/30O02/58O02/59O02. 02 NO ALARM WH... | $2,500 | $0 | Apr 19, 2002 |
| Dec 3, 2001 | 34295366R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG.WALLNOTED:NUMEROUS CRACKS IN BRICKWORK WOME IMPROPERLY FILLED WITH CAULK & MISSING ... | $10,000 | $0 | Jun 6, 2003 |
| Nov 1, 2001 | 34291782H | RESOLVE | Hazardous | FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT: PERIODIC INSPECTON OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $2,500 | $0 | Feb 15, 2002 |
| Nov 1, 2001 | 34291831P | RESOLVE | Hazardous | FAILURE TO SUBMIT A THIRD ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQURED ... | $2,500 | $0 | Feb 15, 2002 |
| Oct 1, 2001 | 34258310P | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. NOTED: NUMEROUS MORTAL JOINTS CAULKED INSTEAD OF POINTED MISSING MORTAR T... | $2,500 | $0 | Nov 23, 2001 |
| Aug 20, 2001 | 34292149R | RESOLVE | Hazardous | FAILURE TO SUBMIT A THIRD ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $2,500 | $0 | Oct 19, 2001 |
| Aug 20, 2001 | 34291521J | RESOLVE | Hazardous | FAILURE TO SUBMIT A FOUR ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED ... | $2,500 | $0 | Oct 19, 2001 |
| Jul 20, 2001 | 34292125M | RESOLVE | Hazardous | FAULURE TO SUBMIT A THIRD ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $2,500 | $0 | Oct 19, 2001 |
| Jul 20, 2001 | 34291506L | RESOLVE | Hazardous | FAILURE TO SUBMIT A FOUR ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED ... | $2,500 | $0 | Sep 21, 2001 |
| Jun 20, 2001 | 34239597H | RESOLVE | Hazardous | FAILRUE TO SUBMIT A THIRD ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED ... | $2,500 | $0 | Aug 17, 2001 |
| Jun 20, 2001 | 34292082L | RESOLVE | Hazardous | FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALL AND APPURTENANCES AS REQUIRED ... | $2,500 | $0 | Aug 17, 2001 |
| May 30, 2001 | 34288888Z | RESOLVE | Hazardous | FAILURE TO MAINTAIN. NOTED: BROKEN WOOD AT VARIOUS STAGES OF DETERIATION, REAR EGRESS METAL AND WOODSTAIR NORTH WEST ... | $800 | $0 | Nov 7, 2003 |
| May 21, 2001 | 34291989P | RESOLVE | Hazardous | FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENNANCES AS REQUIRE... | $2,500 | $0 | Aug 3, 2001 |
| May 21, 2001 | 34248548X | RESOLVE | Hazardous | FAILURE TO SUBMIT A THIRD ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENACES AS REQUIRED B... | $2,500 | $0 | Aug 3, 2001 |
| Apr 20, 2001 | 34278503J | RESOLVE | Hazardous | FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $2,500 | $0 | Jul 6, 2001 |
| Apr 20, 2001 | 34273947H | RESOLVE | Hazardous | FAILURE TO SUBMIT A THIRD ROUND ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQ... | $2,500 | $0 | Jul 6, 2001 |
| Mar 20, 2001 | 34273945Y | RESOLVE | Hazardous | FAILURE TO SUBMIT A THIRD ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED ... | $2,500 | $0 | Jul 6, 2001 |