| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 6, 2025 | 39137694Y | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. OBSERVED UNSAFE STORAGE IN SPRINKLER CONTROL ROOM (MINI FRIDGE,... | $2,500 | $0 | Jun 20, 2025 |
| Feb 6, 2025 | 39137693M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED MISSING DOOR HARDWARE ON SPRINKLER CONTROL ROOM AND I... | $1,250 | $0 | Jun 20, 2025 |
| Feb 6, 2025 | 39137692K | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $2,500 | $0 | Apr 18, 2025 |
| Sep 25, 2023 | 39095691X | RESOLVE | CLASS - 2 | OBSERVED WINDOWS IN COMMON AREA ON THE 3RD AND 4TH FLOOR NOT SECURED PROPERLY FOR CLOSURE. CEILING PENETRATION IN BAS... | $655 | $0 | Dec 1, 2023 |
| May 5, 2023 | 39085613L | RESOLVE | CLASS - 2 | I OBSERVED IN THE BASEMENT AREA THE CONSTRUCTION OF A WOOD STORAGE CABINET NEAR THE ELECTRICAL SERVICE EQUIPMENT. NO ... | $1,250 | $0 | Jan 26, 2024 |
| May 5, 2023 | 39085614N | RESOLVE | CLASS - 2 | I OBSERVED AT THE ENTRANCE OF THE BASEMENT, TWO CIRCUIT BREAKER PANELS, WITH THE RACEWAYS UNSUPPORTED AS REQUIRED. AL... | $1,250 | $1,250 | Jan 8, 2027 |
| May 5, 2023 | 39085612J | RESOLVE | CLASS - 2 | I OBSERVED DEFECTIVE AND UNSECURED GFCI OUTLETS IN THE BATHROOMS.( 3RD FL. BY RM 13 & 4TH, 2ND FLRS BY RM 8)., COMPLY... | $2,000 | $2,000 | Sep 17, 2024 |
| Oct 4, 2019 | 35442272J | RESOLVE | CLASS - 2 | UNSAFE UNSUITABLE ELETRICAL EQUIPMENT IN USE.I OBSERVED IN THE BASEMNET MAIN ELECTRICAL ROOM THE UTILITY ELECETRICAL ... | $800 | $0 | May 15, 2020 |
| Apr 10, 2019 | 39002061X | RESOLVE | CLASS - 2 | LOW WATER CUT OFFS TO BE ON SEPERATE TAPPINGS-RATING PLAT MISSING ON RELIEF VALVE | $0 | $0 | May 31, 2019 |
| Aug 8, 2018 | 32097366R | RESOLVE | CLASS - 2 | B254;15;32A;50A,50B:FEDERAL FST-32 STEEL BOILER:50A-MISSING (GUARDS) ON GAUGE GLASS ASSEMBLY. 50B-BODY DRAIN DISCHARG... | $312 | $0 | Oct 5, 2018 |
| Apr 26, 2018 | 35331025K | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS /CABLE ASSEMBLIES/ENCLOSURES OBSERVED IN BSMT E... | $600 | $0 | Aug 3, 2018 |
| Apr 26, 2018 | 35328724M | RESOLVE | CLASS - 2 | FAILURE TO GROUND ELECTRICAL SYSTEMS OBSERVED IN WATER METER ROOM GROUND(ELECTRODE)CONDUCTOR INSTALLED ON PIPE LOCATE... | $1,200 | $0 | Aug 3, 2018 |
| May 12, 2017 | 35260686M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COKPLIANT MANNER: NO FIRE STOPPING PER BC 712.3;27-345. NOTED: CELLAR LEVEL FIRE STO... | $0 | $0 | Jun 30, 2017 |
| May 12, 2017 | 35260843R | RESOLVE | CLASS - 2 | SEC. 408.2 DRIPS-FUTURE CONNECTIONS EXIT DOWN STREAM OF APPLIANCE. OBSERVED ON 5-12-17 FUTURE GAS CONNECTIONS EXIST D... | $800 | $0 | Jun 30, 2017 |
| May 12, 2017 | 35260442X | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/OUT A PERMIT. OBSERVED IN REAR ALLEYWAY: A SET OF ELECTRICAL WIRES (3-10 AWG) IN THE PROCESS OF BEI... | $800 | $0 | Jun 30, 2017 |
| Apr 27, 2017 | 35184414R | RESOLVE | CLASS - 2 | SEC. 23-44 HVAC CONDENSEUR UNIT NOT PERMITTED IN YARD OR COURT IN MULTIPLE DWELLINGS. NOTED: FOUND AT SIDE COURT OF T... | $400 | $0 | Jul 14, 2017 |
| Sep 6, 2016 | 35207660L | RESOLVE | CLASS - 1 | RESIDENTIAL GAS FLEX USED ON COMMERCIAL EQUIPMETN.ON THE DAY OF 09/06/16 AT THE TIME OF 2:45PM I OBSERVED A GAS FLEX ... | $1,600 | $0 | Nov 4, 2016 |
| Sep 6, 2016 | 35207662P | RESOLVE | CLASS - 2 | DRIPS-FUTURE CONNECTS EXIST DOWNSTREAM OF APPLIANCE. ON TEHD AY OF 09/06/16 AT THE TIME 2:45PM I OBSERVED TEES THROUG... | $800 | $0 | Nov 4, 2016 |
| Sep 6, 2016 | 35207661N | RESOLVE | CLASS - 1 | GAS PIPING NOT LABELED. ON TEH DAY OF 09/06/16 AT HTE TIME OF 2:45PM I OBSERVED THE GAS PIPING WASN'T LABELED IN BASE... | $1,600 | $0 | Nov 4, 2016 |
| Sep 6, 2016 | 35207663R | RESOLVE | CLASS - 2 | FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED. ON THE DAY OF 09/06/16 AT THE TIME OF 2:45PM I OBSERVED NEW SP... | $500 | $0 | Nov 4, 2016 |
| Sep 6, 2016 | 35207664Z | RESOLVE | CLASS - 2 | WORK W/O PERMIT. ON THE DAY OF 09/06/16 AT THE TIME OF 2:45PM I OBSERVED AN HVAC (HEATING,VENTILATION, AND AIR CONDIT... | $800 | $0 | Nov 4, 2016 |
| Sep 6, 2016 | 35207155K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BILDING IN CODE-COMPLIANT MANNER:NO FIRE STOPPING PER BC 7123,-27-345.AT CELLAR INSUFFICIENT FIRE... | $250 | $0 | Nov 4, 2016 |
| Oct 21, 1996 | 34139514P | RESOLVE | Non-Hazardous | PLUMBING WORK W/O PERMIT IN THAT AT FIRST FLOOR IN VARIOUS ROOMS, PIPING FOR KITCHEN SINKS RANGES WASHING MACHINES DR... | $350 | $0 | Dec 13, 1996 |
| Oct 4, 1996 | 34129945H | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY C OF O AT 1ST STRY NORTH AND SO-UTH PRIVATE HALLS,ROOMS ENLARGED FOR COMMERCIAL... | $800 | $0 | Jan 24, 1997 |
| Oct 4, 1996 | 34129944X | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT.WORK NOTED WALLS REMOVED AT NORTH AND SOUTH PRIVA-TE HALLS AT 1ST STRY.ROOMS ENLARGED FOR COMMERC... | $350 | $0 | Jan 24, 1997 |
| Sep 5, 1996 | 34129942M | RESOLVE | Non-Hazardous | WORK WITHOUT PERMITS WORK NOTED WALLS REMOVED AT 1 STRY SOUTH SECTION AND ROOMS ELEMINATED.REMEDY:OBTAIN NEW C OF O O... | $0 | $0 | Nov 8, 1996 |