Maintenance code violations
2087-2089 Creston Avenue, Bronx • Block 03169 • Lot 0045
1,781 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Oct 6, 2025 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR KNOB IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3E, 3rd STORY, 1s... | 3E | Jan 9, 2026 |
| Oct 6, 2025 | B | VIOLATION DISMISSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT APT... | 9D | Nov 10, 2025 |
| Oct 6, 2025 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING. ... | — | Nov 10, 2025 |
| Oct 6, 2025 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE... | 3E | Nov 10, 2025 |
| Oct 6, 2025 | A | NOT COMPLIED WITH | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 9... | — | Jan 9, 2026 |
| Oct 6, 2025 | B | VIOLATION DISMISSED | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT AP... | 9D | Nov 10, 2025 |
| Oct 6, 2025 | B | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE 1st BATHRO... | 3E | Nov 10, 2025 |
| Sep 25, 2025 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | — | Oct 9, 2025 |
| Sep 25, 2025 | A | NOT COMPLIED WITH | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 9... | — | Dec 29, 2025 |
| Sep 22, 2025 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... | — | Oct 27, 2025 |
| Sep 22, 2025 | A | NOT COMPLIED WITH | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 9... | — | Dec 26, 2025 |
| Sep 22, 2025 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET SAFETY COVERS AT EAST WALL AT PUBLIC HALL, 3rd STORY | — | Oct 27, 2025 |
| Sep 22, 2025 | B | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING AND BEHIND WEST W... | 9G | Oct 27, 2025 |
| Sep 22, 2025 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE , MISSING CERAMIC TILES AT SOUTH WAL... | 9G | Oct 27, 2025 |
| Sep 22, 2025 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST... | 3E | Oct 27, 2025 |
| Sep 22, 2025 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET SAFETY COVERS AT NORTH WALL AT PUBLIC HALL, 1st STORY | — | Oct 27, 2025 |
| Sep 22, 2025 | B | VIOLATION DISMISSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL SWITCH AT EAST WALL IN THE BATHROOM LOCA... | 3E | Oct 27, 2025 |
| Sep 22, 2025 | B | VIOLATION DISMISSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR KNOB AT ENTRANCE IN THE 1st ROOM FROM NORTH AT... | 3E | Oct 27, 2025 |
| Sep 22, 2025 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | 3E | Oct 6, 2025 |
| Sep 22, 2025 | B | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING IN THE 1st ROOM F... | 9G | Oct 27, 2025 |
| Sep 22, 2025 | B | VIOLATION DISMISSED | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON ... | 9G | Oct 27, 2025 |
| Sep 22, 2025 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUT... | 9G | Oct 27, 2025 |
| Sep 8, 2025 | B | FALSE CERTIFICATION | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY AT DOOR AT COMPACTOR CLOSET, 10t... | — | Oct 13, 2025 |
| Sep 8, 2025 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 1st STORY | — | Oct 13, 2025 |
| Sep 8, 2025 | A | VIOLATION CLOSED | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Dec 12, 2025 |
| Sep 8, 2025 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | — | Sep 22, 2025 |
| Sep 8, 2025 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT COMPACTOR CLOSET, 3rd STORY | — | Oct 4, 2025 |
| Sep 8, 2025 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING STICK AT LAUNDRY ROOM DOOR AT PUBLIC H... | — | Sep 22, 2025 |
| Sep 8, 2025 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | — | Sep 22, 2025 |
| Sep 8, 2025 | B | VIOLATION CLOSED | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR AT CLOSET AT NORTH WALL IN THE 3rd ROOM FROM N... | 10A | Oct 13, 2025 |
| Aug 29, 2025 | B | FALSE CERTIFICATION | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BUZZER AND RETURN VOICE SYSTEM FROM BUILDING ENTRAN... | 7D | Oct 3, 2025 |
| Aug 29, 2025 | C | DEFECT LETTER ISSUED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 12B, 12t... | 12B | Sep 24, 2025 |
| Aug 28, 2025 | B | VIOLATION CLOSED | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING ... | 3E | Oct 2, 2025 |
| Aug 28, 2025 | B | VIOLATION CLOSED | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON ... | 3E | Oct 2, 2025 |
| Aug 28, 2025 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN DOOR AT ENTRANCE IN THE 3rd R... | 3E | Oct 2, 2025 |
| Aug 28, 2025 | B | FALSE CERTIFICATION | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL/BUZZER INTERCOM SYSTEM FROM BUILDING ENTRANCE ... | 3E | Oct 2, 2025 |
| Aug 14, 2025 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET AT LIGHT SWITCH AT WEST WALL IN THE 2nd ROOM FROM N... | 3E | Sep 18, 2025 |
| Aug 14, 2025 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... | — | Aug 28, 2025 |
| Aug 14, 2025 | B | VIOLATION CLOSED | § 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT CEILIN... | 3E | Sep 18, 2025 |
| Aug 14, 2025 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE... | 3E | Sep 18, 2025 |
| Aug 14, 2025 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORING IN THE 2nd ROOM FROM N... | 3E | Aug 20, 2025 |
| Aug 14, 2025 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 30SQ FT AT CEILING AND... | 3E | Sep 18, 2025 |
| Aug 14, 2025 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1... | 7A | Sep 18, 2025 |
| Aug 14, 2025 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FRO... | 7A | Sep 18, 2025 |
| Aug 14, 2025 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL BEHIND... | 3E | Sep 18, 2025 |
| Aug 14, 2025 | B | VIOLATION CLOSED | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING ... | 7A | Sep 18, 2025 |
| Aug 14, 2025 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL TUB BY WAY OF REGLA... | 7A | Sep 18, 2025 |
| Aug 14, 2025 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST IN THE BATHROOM LOCATE... | 7A | Sep 18, 2025 |
| Aug 14, 2025 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STO... | 3E | Sep 9, 2025 |
| Aug 14, 2025 | B | VIOLATION CLOSED | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON ... | 7A | Sep 18, 2025 |