| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 8, 2026 | 39195349Z | ACTIVE | CLASS - 1 | ATOI, OBSERVED AT PREMISES AT EXP.1, PIPE SCAFFOLD ERECTED WITH INSUFFICIENT PLANKING, IMPROPER GUARRAIL SYSTEM ON BO... | $2,500 | $2,500 | Oct 2, 2026 |
| Jul 8, 2026 | 39195347P | ACTIVE | CLASS - 2 | ATOI, OBSERVED AT PREMISES ADDRESS, PERMIT # X01162611-EL HAS A MODIFIED DATE OF 06/28/2026 AND IS NOT UPDATED AND PO... | $300 | $300 | Sep 18, 2026 |
| Mar 21, 2022 | 39058410H | RESOLVE | CLASS - 2 | FOUND SAFETY WAS LEAKING ON TOP OF BOILER. | $312 | $312 | Sep 9, 2022 |
| May 16, 2019 | 39003071Y | RESOLVE | CLASS - 1 | BUILDING SIDE YARD FIRE PASSAGEWAY EXIT, BLOCKED/OBSTRUCTED BY HOUSEHOLD ITEMS, GARBAGE BAGS AND CONSTRUCTION DEBRIS,... | $312 | $312 | Jul 11, 2019 |
| Jul 6, 2018 | 37011657Z | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMJMISSIONERS ORDER CONTAINED IN SUMMONS/ VIOLATION # 35294413M ISSUED ON 10/19/17 AND TO... | $1,250 | $1,250 | Nov 30, 2018 |
| Jul 6, 2018 | 37011656R | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMJMISSIONERS ORDER CONTAINED IN SUMMONS/ VIOLATION # 35294284P ISSUED ON 10/19/17 AND TO... | $1,250 | $1,250 | Nov 30, 2018 |
| Jun 8, 2018 | 35339298M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO #35329134R ISSUED ON 04/30/18 & TO FILE A CERT OF CORRE... | $625 | $0 | Aug 3, 2018 |
| May 2, 2018 | 35313254P | RESOLVE | CLASS - 1 | AN UNLAWFUL ACT. FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER. FAILURE TO CORRECT & CERTIFY SUMMONS#35294537Y ISS... | $0 | $0 | Jun 29, 2018 |
| Apr 30, 2018 | 35329135Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER:NOTED:OBSERVED @CELLAR'S BOILER ROOM CEILING EXPOSING RE-BARS,PLUMB... | $781 | $0 | Aug 3, 2018 |
| Apr 30, 2018 | 35330601P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION I OBSERVED INSTALLATION OF PROHIBITED RUBB... | $625 | $0 | Aug 3, 2018 |
| Apr 30, 2018 | 35329134R | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:OBSERVED @NORTH SIDE OF BLDG,REAR EXIT PASSAGEWAY LEADING TO TH... | $781 | $0 | Aug 3, 2018 |
| Apr 30, 2018 | 35329120X | RESOLVE | CLASS - 2 | DEFECTIVE WIRING IN USE.OBSERVED IN BASEMENT THE USE OF UNSAFE WIRING METHODS IMPROPER SPLICING AT FUSE BOXES AND CEI... | $400 | $0 | Aug 3, 2018 |
| Jan 23, 2018 | 35312706M | RESOLVE | CLASS - 1 | UNLAWFUL ACTS.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.IN OCTOBER 19,2017.ONE ELECTRICAL VIOLATION WAS ISS... | $0 | $0 | Mar 16, 2018 |
| Dec 20, 2017 | 35281218Y | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35248402J ISSUED ON 10/19/17 AND TO FI... | $800 | $0 | Feb 16, 2018 |
| Oct 19, 2017 | 35294284P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVED IN BASEMENT'S BOILER ROOM AN OPENING IN THE CO... | $500 | $0 | Dec 15, 2017 |
| Oct 19, 2017 | 35294283N | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:OBSERVED AT NORTH EXIT BASEMENT PASSAGEWAY PILES OF GARBAGE,BOX... | $1,200 | $0 | Dec 29, 2017 |
| Oct 19, 2017 | 35294537Y | RESOLVE | CLASS - 1 | UNAPPROVED,UNSAFE,UNSUITABLE,ELECTRICAL EQUIPMENT,APPARATUS,DEVICES,MATERIALS OR WIRING IN USE.OBSERVED IN ALLEYWAY;U... | $1,600 | $0 | Dec 29, 2017 |
| Oct 19, 2017 | 35294413M | ACTIVE | CLASS - 2 | FAIL TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. RE: INSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER ... | $500 | $0 | Dec 15, 2017 |
| May 1, 2017 | 35253448L | RESOLVE | CLASS - 1 | FAILURE TO GROUND ELECTRICAL SYSTEMS.OBSERVED IN BASEMENT A WATER MAIN:THE MAIN GROUNDING CONDUCTOR DISCONNECTED FROM... | $4,800 | $0 | Jul 28, 2017 |
| May 1, 2017 | 35260255K | RESOLVE | CLASS - 2 | FGC401.1/GAS PIPING NOT LABELED.OBSERVED ON 05/01/17 AT ABOVE ADDRESS NEW GAS PIPING INSTALLED WITHOUT PLACING LABELE... | $400 | $0 | Jun 16, 2017 |
| May 1, 2017 | 35253449N | RESOLVE | CLASS - 2 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIAL DEVICES,APPLIANCES OR WIRING IN USE.OBSERVED ARO... | $800 | $0 | Jun 16, 2017 |
| May 1, 2017 | 35271453P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC... | $250 | $0 | Oct 20, 2017 |
| May 19, 2016 | 35177893H | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: PROVIDE REQUIRED CORRIDOR WIDTH PER BC 1016.2;27-369(PARTIAL OBSTR... | $500 | $0 | Feb 3, 2017 |
| May 19, 2016 | 35177892X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES & PUBLIC CORR... | $500 | $0 | Feb 3, 2017 |
| Apr 5, 2010 | 32068101Z | RESOLVE | CLASS - 1 | 16,28A,34A,35,38,47,50,50A,50B,50C,50D. 50- MISSING I.D TAG ON BOILER & OIL BURNER. 50A- MISSING 2ND LOW WATER CUT OF... | $1,000 | $0 | Jun 18, 2010 |