ECB violations
2247 Walton Avenue, Bronx • Block 03186 • Lot 0076
41 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 27, 2025 | 39136557N | ACTIVE | CLASS - 2 | MISALIGNED CAB MIRROR. REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. BRAKE MAINTNENACE TAG MISSING COMPLE... | $625 | $625 | May 23, 2025 |
| Jan 27, 2025 | 39136558P | ACTIVE | CLASS - 2 | MISALIGNED CAB MIRROR. REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. BRAKE MAINTNENACE TAG MISSING COMPLE... | $625 | $625 | May 23, 2025 |
| Dec 9, 2022 | 37025081M | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $0 | $0 | Mar 31, 2023 |
| Jul 24, 2018 | 38264389N | RESOLVE | CLASS - 2 | 97X10 RMDY: REPAIR AND RETURN TO SERVICE IMMEDIATELY. | $0 | $0 | Sep 7, 2018 |
| Jul 10, 2017 | 35238705H | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE WITH AN EXPIRED PERMIT.SUPPORTED SCAFFOLD AT REAR OF BLDG.(EXP 3/5/00)IS AT ... | $830 | $0 | Sep 1, 2017 |
| Mar 20, 2017 | 35226843H | RESOLVE | CLASS - 1 | SEC. 3309.1 FAILURE TO PROTECT OR ADEQUATELY PROTECT ADJOINING PROPERTIES DURING CONSTRUCTION OPRATIONS. NOTED: AT TI... | $4,000 | $0 | May 5, 2017 |
| Jun 22, 2016 | 35196455L | RESOLVE | CLASS - 2 | 3301.7-FAILURE TO PROVIDE REQUIRED DESIGN DRAWING FOR CONSTRUCTION FENCE.8'H PLYWOOD CONSTRUCTION FENCE HAS BEEN EREC... | $0 | $0 | Aug 19, 2016 |
| Jun 21, 2016 | 35183013L | RESOLVE | CLASS - 1 | 3307.6.2 AREA TO BE PROTECTED: NO OVERHEAD PROTECTION.NOTED: AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE. AT EXP#2 ... | $1,600 | $0 | Aug 5, 2016 |
| Jun 21, 2016 | 35183014N | RESOLVE | CLASS - 2 | 3309.10. PROTECTION OF ROOFS:NOT ADEQUATE.NOTED: ACTIVE SITE WORKERS ON SUSPENDED SCAFFOLD CONDUCTING STUCCO WORK THE... | $0 | $0 | Aug 5, 2016 |
| Apr 26, 2016 | 35178314Z | RESOLVE | CLASS - 2 | BC3303.8.1 AIR PRESSURIZED ALARM SYSEM FOR DRY STANDPIPE SYSTEMS DURING CONSTRUCTION OPERATIONS. AT TIME OF INSPECTIO... | $400 | $0 | Jul 8, 2016 |
| Apr 26, 2016 | 35178315K | RESOLVE | CLASS - 1 | BC3308.5 VERTICAL NETTING SYSTEMS. VERTICAL NETTING SHALL BE INSTALLEDAND MAINTAINED TO COVER ALL UNENCLOSED PERIMETE... | $1,600 | $0 | Jul 8, 2016 |
| Apr 7, 2016 | 35183307R | RESOLVE | CLASS - 2 | 3301.6.1 DESIGN:45 CATCH ALL PLATFORM.NOTE:AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE.AT EXPO#3 REAR OF SITE NEXT ... | $400 | $0 | Jun 3, 2016 |
| Apr 7, 2016 | 35183308Z | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.NOTE OBSERVED ACTIVE JOBSITE EREC... | $250 | $0 | Jun 3, 2016 |
| Apr 7, 2016 | 35183306P | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS.NOTE:OBSERVED ACTIVE JOBSITE ERECTED... | $1,200 | $0 | Jul 8, 2016 |
| Apr 7, 2016 | 35183309K | RESOLVE | CLASS - 2 | 3307.43 VEHICULAR TRAFFIC:BARRICADES-AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE ERECTED TO THE 11 FL.AT EXPO#1 AT ... | $400 | $0 | Jul 8, 2016 |
| Apr 7, 2016 | 35183310H | RESOLVE | CLASS - 2 | FAIL TO MAINTAIN:HOUSEKEEPING.NOTE:ACTIVE SITE ERECTED 11 FLOORS.SIDEWALK SHED AT EXPO#1 HAS DEBRIS,BRICKS,SCAFFOLD P... | $0 | $0 | Jun 3, 2016 |
| Mar 15, 2016 | 35165241Y | RESOLVE | CLASS - 2 | SEC. 3301.9.5 FAILURE TO PROVIDE REQUIRED SIDEWALK SHED PARAPET SIGN ON SHED AT EXP#1. THIS IS A RENEW 11 STY BLDG UN... | $0 | $0 | May 6, 2016 |
| Feb 3, 2016 | 35165758R | RESOLVE | CLASS - 1 | SEC. 3310.8 SITE SAFETY COORDINATORS DUTIES. NOTE: OBSERVED ACTIVE JOBSITE ERECTED 11 FLOORS ABOVE THE GROUND. SSC AK... | $0 | $0 | Sep 16, 2016 |
| Feb 3, 2016 | 35165754J | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS: SCAFFOLD NOTE OBSERVED ACTIVE JOBSI... | $0 | $0 | Apr 1, 2016 |
| Feb 3, 2016 | 35165757P | RESOLVE | CLASS - 2 | SEC. 3308.5 VERTICLE NETTING: VERTICAL NOT MAINTAINED. NOTE: AT THE 10 & 11 FLOOR AT EXP#3 AT SITE THE VERTICLE SAFET... | $0 | $0 | Apr 1, 2016 |
| Feb 3, 2016 | 35165756N | RESOLVE | CLASS - 2 | SEC. 3307.2 STREETS INCLUDING SIDEWALKS: NOT PROTECTED. NOTE: ACTIVE JOBSITE ERECTED 11FL ABOVE GROUND. AT EXP#1 IN T... | $0 | $0 | Apr 1, 2016 |
| Feb 3, 2016 | 35165755L | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTE: ACTIVE JOBSITE ERECTED 11 STY ... | $1,200 | $0 | Apr 1, 2016 |
| Oct 28, 2015 | 35160138N | RESOLVE | CLASS - 2 | BC28-204.7 SUBMITTAL OF CONSTRUCTION DOCUMENTS AS NOTED: AT TIME OF INSPECTION AT ACTIVE JOB SITE OBSERVED STEEL/MASO... | $400 | $0 | Dec 18, 2015 |
| Oct 28, 2015 | 35160137L | RESOLVE | CLASS - 1 | BC3308.1.3 FAILURE TO PROVIDE HORIZONTAL NETTING DURING NEW CONSTRUCTION: AS NOTED AT TME OF INSPECTION NEW BUILDING ... | $0 | $0 | Dec 18, 2015 |
| Sep 3, 2015 | 35130565K | RESOLVE | CLASS - 1 | HOLES/OPENINGS NOT COVERED UPON INSPECTION AS NOTED AT ACTIVE CONSTRUCTION SITE UP TO 8TH FL LEVEL. THERE ARE HOLES 3... | $2,400 | $0 | Oct 30, 2015 |
| Sep 3, 2015 | 35130562P | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS: NO HORIZONTAL NETS"PARTIAL STOP WOR... | $1,000 | $0 | Dec 11, 2015 |
| Sep 3, 2015 | 35130564Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS: UPON INSPECTION AS NOTED AT ACTIVE CONSTRUCTION S... | $2,400 | $0 | Oct 30, 2015 |
| Sep 3, 2015 | 35130563R | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE DESIGN DRAWING"PARTIAL STOP WORK ORDER"ON ALL TEMPORARY PLATFORMS ISSUED PURSUANT TO 28-207.2 & PO... | $500 | $0 | Oct 30, 2015 |
| Sep 3, 2015 | 35130566M | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION. NO GUARDRAILS UPON INSPECTION AS N... | $1,200 | $0 | Oct 30, 2015 |
| Mar 26, 2015 | 35122493K | RESOLVE | CLASS - 1 | UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF STOP WORK ORDER.FULL STOP WORK ORDER.CONTRACTOR INSTALLED PLANKS ON 1ST ... | $4,800 | $0 | May 15, 2015 |
| Mar 18, 2015 | 35122492Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS @ JOB SITE @ TIME OF INSP.-NOTED:PLANS PROVIDED HAS NO(STAIRWAY),NO PERMIT... | $0 | $0 | May 15, 2015 |
| Mar 18, 2015 | 35122491R | RESOLVE | CLASS - 1 | 3304.7 SAFE MEANS OF INGRESS & EGRESS.LADDER PROVIDED HAS BEEN SEPARATED INTO TWO HALFS AND IS SHORT BY 4FL.REM:STOP ... | $1,600 | $0 | May 15, 2015 |
| Mar 18, 2015 | 35122490P | RESOLVE | CLASS - 1 | FAILURE TO HAVE SITE SAFETY MANAGER OR COORINATOR PRESENT AS REQUIRED :NOTED:BUILDING TO BE ERECTED TO 11 FLS-NO COOR... | $1,200 | $0 | May 15, 2015 |
| Jan 29, 2015 | 35098448Y | RESOLVE | CLASS - 2 | BC3307.7 FAILURE TO PROVIDE JOBSITE FENCE AS PER CODE.UPON INSPECTION AS NOTED AT ACTIVE CONSTRUCTION SITE CONTRACTOR... | $400 | $0 | Mar 20, 2015 |
| Jan 29, 2015 | 35098449X | RESOLVE | CLASS - 2 | BC3310.5 FAILURE TO PROVIDE SITE SAFETY MANAGER/COORDINATOR. UPON INSPECTION AS NOTED AT ACTIVE CONSTRUCTION SITE.EXC... | $400 | $0 | Mar 20, 2015 |
| Nov 25, 2014 | 35098440J | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION."FULL STOP WORKORDER"ISSUED PURSUANT TO 28-207.2 AND POSTED AT ... | $400 | $0 | Jan 30, 2015 |
| Aug 19, 2014 | 35098636L | RESOLVE | CLASS - 2 | PROJECT INFO:FENCE VIEWING PANEL NOT PROVIDED OR NOT IN COMPLIANCE W/SECTION @ CONST SITE.@ TIME OF INSP NOTED THAT O... | $4,000 | $0 | Oct 3, 2014 |
| May 20, 2014 | 35092738P | RESOLVE | CLASS - 2 | SIDEWALK SHED/JOB SITE FENCE NOT PAINTED PURSUANT TO SUBSECTIONS BC3307.6/BC3307.7.@ TIME OF INSP NOTED THAT JOB SITE... | $800 | $0 | Aug 15, 2014 |
| May 20, 2014 | 35092740Y | RESOLVE | CLASS - 2 | SIDEWALK SHED/JOB SITE FENCE NOT PAINTED PURSUANT TO SUBSECTION BC 3307.6/BC3307.7.@ TIME OF INSP NOTED THAT JOB SITE... | $800 | $0 | Aug 15, 2014 |
| May 20, 2014 | 35092739R | RESOLVE | CLASS - 2 | PANEL/SIDEWALK SHED PARAPET/CONST SIGN NOT PROVIDED OR NOT IN COMPLIANCE W/ SECTION.@ TIME OF INSP VIEWING PANEL NOT ... | $800 | $0 | Aug 15, 2014 |
| May 20, 2014 | 35092741X | RESOLVE | CLASS - 2 | PANEL/SIDEWALK SHED PARAPET/CONST SIGN NOT PROVIDED OR NOT IN COMPLIANCE W/ SECTION.CODE,@ TIME OF INSP VIEWING PANEL... | $800 | $0 | Aug 15, 2014 |