What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Grand Central 44 min 10 walking, 34 riding
- Union Square 48 min 10 walking, 38 riding
- Times Square 51 min 10 walking, 41 riding
- Fulton Street 54 min 10 walking, 44 riding
- Penn Station 56 min 10 walking, 46 riding
- Downtown Brooklyn 62 min 10 walking, 52 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Bus
Citi Bike
Places nearby
188 Bakery Cuchifritos
188 Bakery Cuchifritos is a hidden gem in the Bronx serving up delicious traditional Puerto Rican cuchifritos. Enjoy ...
188 Cuchifritos
188 Cuchifritos is a beloved Bronx spot offering authentic Puerto Rican cuisine. Specializing in crispy fried pork di...
Cơm Tấm Ninh Kiều
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
HPD violation Jul 20, 2026
Class C
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL...
-
HPD violation Jul 20, 2026
Class B
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ASSEMBLY'S AT COMPACTOR CLOSET DOOR AT CO...
-
HPD violation Jun 8, 2026
Class C
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL...
-
HPD violation May 18, 2026
Class B
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR KNOBS AT COMPACTOR ROOM AT PUBLIC HALL, 3rd STORY, SECTION AT NORTH
-
HPD violation May 18, 2026
Class B
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR KNOBS AT COMPACTOR ROOM AT PUBLIC HALL, 5th STORY, SECTION AT NORTH
-
HPD violation May 18, 2026
Class C
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL...
2025
-
CLASS - 2
1RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103...
2024
-
CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #35577638N ISSUED ON 6/16/2021, AND FAILURE TO FILE ...
2023
-
DOB violation Oct 4, 2023
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
DOB violation Oct 4, 2023
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
DOB violation Jun 20, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
-
CLASS - 2
W/O A PERMIT. NOTED: AT CELLAR - SOUTH AT WEST - WATER & WASTE LINES INSTALLED FOR A WASHER & RESIDENTIAL SINK. GAS L...
-
CLASS - 1
WORK WITHOUT A PERMIT. NOTED: AT CELLAR SOUTH AT WEST - FULL HEIGHT PARTITION WALLS ERECTED TO CREATE (2) BTHRMS & (2...
-
CLASS - 1
CONTRARY TO C-OF-O # 443813 WHICH INDICATES NO CELLAR APTS. AT TIME OF INSPECTION (2) APTS HAVE BEEN CREATED & OCCUPI...
-
CLASS - 2
CONTRARY TO C-OF-O # 443813 WHICH INDICATES CELLAR AS BOILER, STORAGE, METER RM, SUPER WORKSHOP, WATER COMPARTMENT: A...
2022
-
DOB violation Dec 15, 2022
RWNRF-RETAINING WALL NONE
FAILED TO FILE CYCLE 1 TECHNICAL REPORT BY 12/31/2018 PER RCNY 103-09
2021
-
DOB violation Jan 8, 2021
E-ELEVATOR ELEVATORREQUIRED
-
DOB violation Jan 8, 2021
E-ELEVATOR ELEVATORREQUIRED
2020
2015
-
Alteration Type II
ACTIVATE GAS PORTION OF EXISTING GAS/OIL BURNER ON NYC BOILER NO. MD14591-01 AND INSTALL NEW GAS SERVICE, METER AND P...
2014
-
Alteration Type II
ACTIVATE GAS PORTION OF EXISTING GAS/OIL BURNER ON NYC BOILER NO. MD14591-01 AND INSTALL NEW GAS SERVICE, METER AND P...
2012
-
Alteration Type II
APPLICATION FILE TO RENOVATE FIRE,SMOKE AND WATER DAMAGE TO APT. 1D, 2D & 3D. NO CHANGE IN USE, OCCUPANCY OR EGRESS
2010
2008
-
Alteration Type III
ERECT 50 L.F X 60' TALL IN THE SIDE OF THE BUILDING. THE SCAFFOLD TO ORIGINATE OFF THE GROUND SHED DURING REMEDIAL RE...
-
Alteration Type II
PROPOSED APROX 50 LINEAR FEET REPAIR/REBUILD PARAPHET WALL IN THE SIDE WALL.NO CHANGE IN USE, EGRESS OR OCCUPANCY.
2005
-
Alteration Type II
CHANGE GRADE OF FUEL OIL FROM #6 TO #4. REMOVE OIL PREHEATER AND_INSTALL ANTISYPHON DEVICE AT HIGH POINT OF FUEL OIL ...
2004
2003
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records