Skip to content

Maintenance code violations

2-4 West 192 Street, Bronx • Block 03201 • Lot 0030

444 records

HPD grades a violation A for non-hazardous through C for immediately hazardous.

Issued Class Status Violation Apartment Correct by
Dec 5, 2024 B NOV SENT OUT § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRE ELEC... 5A Jan 9, 2025
Oct 7, 2024 A NOT COMPLIED WITH § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXIS... Jan 10, 2025
Jul 29, 2024 C VIOLATION CLOSED § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... Aug 12, 2024
Jul 29, 2024 A VIOLATION DISMISSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FLOOR TILES, IN THE KITCHEN LOCATED ... 2J Nov 1, 2024
Apr 2, 2024 A VIOLATION DISMISSED (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... Jul 6, 2024
Feb 14, 2024 C NOV SENT OUT § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORY, ... 3D Feb 14, 2024
Feb 14, 2024 C NOV SENT OUT § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3r... 3D Feb 14, 2024
Feb 14, 2024 C VIOLATION CLOSED § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM Feb 20, 2024
I VIOLATION DISMISSED §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
Jul 25, 2023 C VIOLATION CLOSED § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CL... Aug 8, 2023
Jul 25, 2023 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE 13TH MARBLE TREAD FROM BOTTOM UP AT PUBLIC HALL STAIRS, 5th STORY Aug 29, 2023
Jul 25, 2023 C VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DEFECTIVE 2ND WINDOW FROM NORTH AT THE EAST WALL AT... Jul 31, 2023
Jul 25, 2023 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE 4TH MARBLE TREAD FROM BOTTOM UP AT PUBLIC HALL STAIRS, 4th STORY Aug 29, 2023
Jul 25, 2023 B VIOLATION CLOSED § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE 1ST CEILING LIGHT FIXTURE FROM NORTH AT PUBLIC HALL... Aug 29, 2023
Mar 28, 2023 C VIOLATION CLOSED § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT BUILDING ... Apr 11, 2023
Mar 28, 2023 C VIOLATION CLOSED § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT REAR ENTR... Apr 11, 2023
Mar 17, 2023 A VIOLATION DISMISSED (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... Jun 20, 2023
Jan 27, 2023 B VIOLATION DISMISSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... 3R Mar 3, 2023
Jan 27, 2023 B VIOLATION DISMISSED § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM SOUT... 3R Mar 3, 2023
Jan 27, 2023 C VIOLATION CLOSED § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .... IN THE ... 3R Feb 10, 2023
Jan 27, 2023 B VIOLATION DISMISSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS AND CE... 3R Mar 3, 2023
Jan 27, 2023 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL APPROX 10 SQ FT, NO... 3R Mar 3, 2023
Jan 27, 2023 B VIOLATION DISMISSED § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 3R, 3rd STORY, 1st... 3R Mar 3, 2023
Nov 21, 2022 C NOV SENT OUT § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN TH... 6B Dec 5, 2022
Nov 21, 2022 C NOV SENT OUT § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... 6B Dec 17, 2022
Oct 11, 2022 B VIOLATION DISMISSED § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR P... 1B Nov 15, 2022
Oct 11, 2022 B VIOLATION DISMISSED § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). (MISSING) IN THE ENTIRE APARTMENT LOCATED... 1B Nov 15, 2022
Oct 11, 2022 B VIOLATION DISMISSED § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR (MISSING) IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STOR... 1B Nov 15, 2022
Sep 14, 2022 C VIOLATION DISMISSED HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd ... 2J Oct 10, 2022
Sep 13, 2022 C DEFECT LETTER ISSUED § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT ... 1F Oct 7, 2022
Sep 13, 2022 B VIOLATION CLOSED § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS... 2D Oct 18, 2022
Sep 13, 2022 B VIOLATION CLOSED § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS... 2E Oct 18, 2022
Sep 13, 2022 C VIOLATION CLOSED § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT ROOF BULK... Sep 27, 2022
Sep 13, 2022 B VIOLATION CLOSED § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS... 4C Oct 18, 2022
Sep 13, 2022 C DEFECT LETTER ISSUED § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS ... 1F Oct 7, 2022
Sep 12, 2022 A VIOLATION DISMISSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... 1F Dec 16, 2022
Sep 12, 2022 C VIOLATION DISMISSED § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... 1F Oct 8, 2022
Sep 12, 2022 B VIOLATION DISMISSED § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... IN... 1F Oct 17, 2022
Sep 12, 2022 C VIOLATION CLOSED § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE INOPERABLE H... 1F Sep 26, 2022
Sep 12, 2022 A VIOLATION DISMISSED § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT 1st CLOSET FROM EAST AT S... 1F Dec 16, 2022
Jul 11, 2022 B VIOLATION CLOSED § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FRO... 2J Aug 15, 2022
Jul 11, 2022 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WA... 2J Aug 15, 2022
Jul 11, 2022 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN THE BA... 2J Aug 15, 2022
Jul 11, 2022 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BA... 2J Aug 15, 2022
Jun 30, 2022 C VIOLATION CLOSED § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DUE TO DEFEC... 3C Jul 26, 2022
Jun 30, 2022 C VIOLATION CLOSED § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... 3C Jul 26, 2022
Jun 24, 2022 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN TH... 3C Jul 29, 2022
Jun 24, 2022 B NOV SENT OUT § 27-2056.7 AND 27-2056.17 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PER... 5P Jul 29, 2022
Jun 24, 2022 B NOV SENT OUT § 27-2056.7 AND 27-2056.17 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PER... 3C Jul 29, 2022
Jun 24, 2022 B VIOLATION CLOSED § 27-2056.7 AND 27-2056.17 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PER... 4D Jul 29, 2022