ECB violations
2505 Aqueduct Avenue West, Bronx • Block 03214 • Lot 0066
52 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 27, 2025 | 39158538P | RESOLVE | CLASS - 2 | CLASS 2 ITEMS: 1) DOOR GIBS WORN, REPLACE WHERE NECESSARY. 2) IN CAR COMMUNICATION INOPERATIVE, REPAIR. | $655 | $0 | Oct 31, 2025 |
| Feb 18, 2022 | 38274336Z | RESOLVE | CLASS - 1 | 97X17: 97-X-17 CLASS 1 RESTORE TO SERVICE. REPAIR ELEVATOR & RESTORE TO SERVICE IMMEDIATELY. CALL N.Y.C DOB ELEVATOR ... | $0 | $0 | May 20, 2022 |
| Feb 10, 2022 | 39056091K | RESOLVE | CLASS - 1 | OUT OF SERVICE | $0 | $0 | Jun 3, 2022 |
| Aug 14, 2021 | 39046041N | RESOLVE | CLASS - 2 | CLASS 2 ITEMS,/ DEVICE STUCK AT 5 FLOOR FOR 10 TO15 MINUTES REMEDY; REPAIR,/ IN CAR PHONE NOT WORKING REMEDY; REPAIR,... | $625 | $0 | Nov 19, 2021 |
| Jun 4, 2021 | 35582181Z | RESOLVE | CLASS - 2 | WORK WITHOUT A PERMIT I OBSERVED 2 AWNINGS AND 2 SIGNS THAT READ LIL INVESTORS LEAKING CENTER APPROXIMATELY 6FT X 2FT... | $1,250 | $0 | Nov 19, 2021 |
| Jan 5, 2021 | 39034277L | RESOLVE | CLASS - 1 | THE ONLY ELEVATOR IN BUILDING(OR SECTION OF BUILDING) OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT-... | $1,250 | $0 | Feb 19, 2021 |
| Aug 3, 2020 | 37020058L | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#38270441M ISSUED ON 7/15/2019,AND TO FILE ... | $1,250 | $0 | Feb 16, 2021 |
| Jun 29, 2020 | 38273433X | RESOLVE | CLASS - 1 | CEASE USE(5X10/8V1/23X10)(7J1/59BB5)5-C/U DOOR CONE RESTRICTOR INOPERATIVE REPAIR/8-C/U FLOOR STOPS OFF LEVEL CREATIN... | $1,280 | $0 | Sep 4, 2020 |
| Jun 17, 2020 | 38273430K | RESOLVE | CLASS - 1 | 97X17,42M5,68B7 ENTIRE DEVICE INOPERATIVE UPON INSPECTION ARRIVAL MUSTREPAIR DEVICE BACK TO SERVICE AND CONTACT NYC D... | $3,155 | $0 | Aug 21, 2020 |
| Jun 9, 2020 | 39023693R | RESOLVE | CLASS - 1 | THE ONLY ELEVATOR IN BUILDING OUT OR SERVIVE . UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING A HA... | $1,250 | $0 | Jul 31, 2020 |
| Apr 1, 2020 | 39020650N | RESOLVE | CLASS - 1 | CLASS 1 = NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER, REMEDY; FILE APPLICATION, INSTALL DLM AND PERFORM AND... | $1,250 | $0 | Dec 18, 2020 |
| Aug 1, 2019 | 38265433X | RESOLVE | CLASS - 1 | CU-1L10 IN CAR STOP SWITCH DEFECTIVE WHEN PULLED CAR TAKE OFF THEN ITSTOPS MUST REPAIR AND CALL FOR REINSPECTION AT 2... | $1,250 | $0 | Sep 20, 2019 |
| Jul 30, 2019 | 38270792Y | RESOLVE | CLASS - 1 | CU43N10; CU08V01; 16M07; 17M07. 2-CEASE USE ITEMS; 1-43N-REPAIR BY PASS REVERSE PHASE RELAY; 2-08V-ADJSUT LEVELING ON... | $1,250 | $0 | Sep 20, 2019 |
| Jul 15, 2019 | 38270441M | RESOLVE | CLASS - 2 | 100M07;19M07;16M07;RC02X10; 29B10; 34D06;26D06;100M07;R/C08V01;56Y13;16I10;58H10;60Q03;57B11;68B07. 100-PROVIDE FIRE ... | $625 | $0 | Aug 30, 2019 |
| Jul 9, 2019 | 38270531X | RESOLVE | CLASS - 1 | C/U 29-B01,08V01,02B10,46M07,35M07,56Y10,58H10,52O02; (29-B)ADJUST CAR DOOR OPERATOR,(08-V)ADJUST CAR LANDING (02-B)R... | $1,250 | $0 | Aug 30, 2019 |
| Jul 28, 2017 | 37005890Y | RESOLVE | CLASS - 1 | GOVERNOR MISSING PROVIDE SEAL.PROVIDE GOVERNOR SEAL AND CONTACT NYC DOB FOR RE-INSPECTION WHEN INSTALLED | $1,000 | $0 | Nov 3, 2017 |
| Jul 26, 2017 | 38257060M | RESOLVE | CLASS - 1 | CU05A10,40M07,02L10. 05A10-DOOR ZONE RESTRICTOR IS ALTERED. THIS IS ASAFETY DEVICE TO ENSURE ELEVATOR PASSENGER SAFET... | $1,000 | $0 | Sep 15, 2017 |
| Dec 14, 2016 | 38251719Y | RESOLVE | CLASS - 1 | 5A10,8J10,59U15/5A10-CAB DOOR RESTRICTOR HAS BEEN ALTERED(REPAIR);59U15-BRAKE TAG IS MISSING PROVIDE. | $5,000 | $0 | Feb 3, 2017 |
| Oct 26, 2016 | 38250630N | RESOLVE | CLASS - 1 | 05X10,05J01,08V01. 05-CAR DOOR ZONE RESTRICTOR INOPERATIVE MUST REPAIR IMMEDIATELY; 05-ADJUST CAR DOOR TO FULLY OPEN ... | $1,000 | $0 | Dec 16, 2016 |
| May 22, 2015 | 38236171M | RESOLVE | CLASS - 2 | 67X10,11X10,40P07,37P07. 67-REPAIR EMERGENCY COMMUNICATION (PHONE) IN ELEV CAB; 11-ELEVATOR NOT RESPONDING TO 3RD FLR... | $250 | $0 | Jul 17, 2015 |
| Jul 24, 2013 | 35030133Z | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD PUBLIC AND PROPERTY. NOTED: INTERIOR RENOVATION FOR 43 APTS VIA PERMIT #220324940 INCLUDING REPL... | $1,200 | $0 | Oct 11, 2013 |
| Mar 23, 2011 | 38215774Z | RESOLVE | CLASS - 2 | 07X10,37T07,33M07,70Z02,72M07,77M07,98U15. 07X10- REPAIR DOOR OPEN BUTTON IN CAR BUTTON STATION. 37T07- PROVIDE SIGN ... | $2,500 | $0 | Jul 15, 2011 |
| Dec 1, 2010 | 38213867Z | RESOLVE | CLASS - 2 | 41D06,60X10,70Z09. 70- REMOVE WATER FROM PIT | $250 | $0 | Feb 4, 2011 |
| Feb 11, 2010 | 38208398Z | RESOLVE | CLASS - 1 | 97X10. 97X10-ONLY ELEVATOR IN BLDG IS OUT OF SERVICE THEREBY CREATING CONDITION DANGEROUS TO HUMAN LIFE AS PER 1RCNY ... | $5,000 | $0 | Sep 9, 2010 |
| Jan 19, 2010 | 38207570R | RESOLVE | CLASS - 1 | 97/X/10-97-X-10-ONLY ELEVATOR IN BLDG IS OUT-OF-SERVICE THERE BY CREATING CONDITION DANGEROUS TO HUMAN LIFE. REPAIR I... | $1,000 | $0 | Apr 9, 2010 |
| Oct 27, 2009 | 32067192Z | RESOLVE | CLASS - 1 | 15,28B,32A,34,40,50A,B,C,D,E,F,51. 50A-SUMP PUMP NO WORKING BOILER RM FLOODED.50B REAR DOOR MUST BE SEALED AND FRONT ... | $1,000 | $0 | Dec 18, 2009 |
| Sep 3, 2009 | 32067113L | RESOLVE | CLASS - 2 | 28A,28B,16,42,34A,50A-E 50A-BOILER INOPERATIVE 50B-REMOVE WASTE OIL FROM BOILER RM 50C-CONTROL COVER MISSING 50D-FLUE... | $500 | $0 | Dec 4, 2009 |
| Jan 7, 2009 | 38200309L | RESOLVE | CLASS - 2 | 97X10, 52K10, 52H10, 70Z09, 100M10, 42Q03, 56Y13, 37P16. 97X10- 1RCNY 11-02 ONLY ELEVATOR IN BLDG OUT OF SERVICE. RES... | $500 | $0 | Mar 6, 2009 |
| Jul 15, 2008 | 38188946P | RESOLVE | CLASS - 2 | 05J10.70Z09.56Y10.52K10.41D06.37D0.53K10.21Q03.15I10.100M07.97O02.70209 REMOVE WATER & CLEAN PIT 52K10 HOIST ROPES AR... | $500 | $0 | Sep 5, 2008 |
| Dec 18, 2007 | 34620387M | RESOLVE | Hazardous | FAILURE TO MAINTAIN. WINDOW AC UNITS IMPROPERLY INSTALLED W/LOOSE BLOCKING AND BRICKS(INADEQUATE0SUPPORTS THROUGHOUT ... | $2,000 | $0 | Aug 25, 2008 |
| Oct 30, 2007 | 34418538L | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ELEVATOR LANDING SIGN THAT SHALL READ. IN CASE OF FIRE USE STAIRS UNLESS OTHERWISE INSTRUCTED. @ T... | $1,200 | $0 | Oct 24, 2008 |
| Aug 4, 2007 | 34592079P | RESOLVE | Hazardous | FAILURE TO MAINTAIN. NOTED: WINDOW A.C UNITS IMPROPERLY INSTALLED W/ LOOSE BLOCKING & LOOSE BRICKS INADEQUATELY MOUNT... | $2,000 | $0 | Aug 25, 2008 |
| May 1, 2007 | 34490661N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN PLUMBING &/OR APPURTENANCE. POOL OF WATER IN SIDE COURT YARD OF BLDG. REMEDY: MAINTAIN PLUMBING &... | $800 | $0 | Jul 6, 2007 |
| Mar 27, 2007 | 34569976J | RESOLVE | Hazardous | FAILURE TO MAINTAIN:NOTE:WINDOW( )AC UNITS INPROPERLY INSTALLED W/LOOSE BLOCKING & LOOSE BRICKS-THROUGHOUT-INADEQUATE... | $800 | $0 | Jun 15, 2007 |
| Nov 29, 2006 | 38159221P | RESOLVE | Non-Hazardous | 8V1,16M7,39P16,66O2,83#10. 8-CAR NOT LEVEL W/ LANDING BELOW 7 IN.16-LOBBY HOISTWAY DOOR MISSING. 66-PIT DIRTY.83-CAR ... | $350 | $0 | Nov 16, 2007 |
| Nov 2, 2006 | 34540479J | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE REQUIRED MEANS OF EGRESS-FIRE ESCAPE HAVE OBSTRUCTIONS.1-PLASTIC DEBRIS.2-CHRISTMAS LIGHTS.3-FLOWE... | $480 | $0 | Dec 22, 2006 |
| Nov 2, 2006 | 34540480R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN-A/C UNIT ON THE 5FL FRONT IS LEANING & NOT SUPPORTED.REMEDY:SUBMIT ENGINEERS REPORT ON STRUCTURAL... | $800 | $0 | Dec 22, 2006 |
| Oct 6, 2006 | 38161893K | RESOLVE | Hazardous | CEASE USE.HAZARDOUS.3I10/84L10/07L10/08V01.(03-I-10)REPAIR WALLS INSIDE ELEVATOR.(84-L-10)REPAIR NOISE COMING FROM OV... | $500 | $0 | Dec 1, 2006 |
| Dec 28, 2005 | 38156194P | RESOLVE | Non-Hazardous | 07X10/66Z09/05J10/60U15/52K10/36D06/51K10/51H10. 07- REPAIR SAFETY EDGE 66- REMOVE WATER & CLEAN PIT. 60- PROVIDE CIT... | $880 | $0 | Feb 21, 2006 |
| Nov 15, 2005 | 38155621X | RESOLVE | Non-Hazardous | 66O02/66Z09/51K10/51H10/52K10/21Q03/34Q03. 66- REMOVE WATER AND CLEAN PIT. (THERE IS ABOUT A 12-INCHES OF WATER IN PI... | $350 | $0 | Apr 28, 2006 |
| Oct 3, 2005 | 38154047X | RESOLVE | Non-Hazardous | 12B07/08V10/66O02/84X10/09V10/40M07/40M07 (12-B-07) PROVIDE PROPER LIGHTING INSIDE ELEVATOR (08-V-10)- FLOOR STOPS OF... | $0 | $0 | Nov 18, 2005 |
| Sep 26, 2005 | 38154865H | RESOLVE | Non-Hazardous | 83X10/60T15/63T15/36O2/32O2/33O2/35O2/38O2/66O2/67O2/68O2/71O2 83 RESTORE TO SERVICE SO FULL INSPECTION CAN BY MADE B... | $180 | $0 | Feb 1, 2006 |
| Oct 12, 2004 | 38149664P | RESOLVE | Non-Hazardous | 36M07 83BB05 34B10 23M07 52K11 66Z13 40M07 43H08 55Y13 56H10 36M07 PROVIDE LOCK FOR OVERHEAD DOOR/34B10 EXPOSED WIRIN... | $2,500 | $0 | Nov 26, 2004 |
| Dec 4, 2002 | 38135467Z | RESOLVE | Non-Hazardous | 81U05-05L11. 81-DATE OF TAG 4/97 05-NOT OPENING FULLYARD BANGS ON CLOSE. | $0 | $0 | Jan 17, 2003 |
| Nov 20, 2002 | 34342804R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BLDG.WALL.(EXTERIOR)NOTED:CHIMNEY AT WESTSIDE OF BLDG HAS VERTICAL APPROX.7" NEAR ROOF LEVEL,ALSO... | $350 | $0 | Jun 6, 2003 |
| Oct 16, 2002 | 38125895X | RESOLVE | Non-Hazardous | 75#05/03D06/05L01/08V01. 75 DATE OF TAG 4/97. 03 STRICKE POST SIDE OF CLOSES HAND TO STRIKE POST AND SCROPING RETARN ... | $180 | $0 | Dec 6, 2002 |
| Sep 12, 2002 | 34342188M | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. DEFECT: APPROX 2'W X 3'L X 2'DEEP HOLE WAS CREATED TO INSTALL NEW PIPES FOR BOILER. CONST DEBRIS... | $180 | $0 | Nov 15, 2002 |
| Dec 2, 1999 | 38092573P | RESOLVE | Non-Hazardous | 3I11,15M11,5#1,28H11,57Z2. *3 DAMAGED CAR PANEL, *15 ROLLER GUIDE MISSING, *5 BIG GAP ON CAR DOOR WHEN CLOSED, *28 GU... | $0 | $0 | Feb 11, 2000 |
| Feb 11, 1999 | 38083899K | RESOLVE | Non-Hazardous | 14M,74,74F,57O. NO CERTIFICATE FRAME, BIG GAP WHEN CB DOOR IS CLOSED, CAB DOOR SLAM OPEN, PIT DIRTY. | $180 | $0 | Apr 23, 1999 |
| May 2, 1998 | 38073461R | RESOLVE | Non-Hazardous | 50F12, 7316, 14M7, 28B1, 11M7, 74M7, 75U5, 74O2. PROVIDE CITY I.D. PROVIDE GUARD FOR LIGHT PROVIDE COVER FOR BOX TOP ... | $0 | $0 | Jun 26, 1998 |