Skip to content

ECB violations

2287 University Avenue, Bronx • Block 03218 • Lot 0065

23 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 17, 2022 35569100L RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35378322P ISSUED 3/31/21 AND FILE CERTIFI... $1,250 $0 Sep 23, 2022
Nov 3, 2021 35528738J RESOLVE CLASS - 2 FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V35378322P ISSUED3/31/21 &TO FILE C/C PURSUANT TO28-201... $0 $0 May 13, 2022
Aug 3, 2021 35535155N RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35378322P ISSUED ON 3/31/2021 AND TO F... $3,125 $0 Nov 12, 2021
May 24, 2021 35531273X RESOLVE CLASS - 2 FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V35378322P ISSUED 3/31/21&TO FILE C/C PURSUANT TO28-201... $1,250 $0 Aug 6, 2021
Mar 31, 2021 35378322P RESOLVE CLASS - 1 ALTERED/CHANGE BUILDING OCCUPIED W/O A VALID C OF O AS PER 28-118.3.1-28-118.3.2. AT TIME OF INSPECTION,NOTED:AT CELL... $2,500 $0 Jul 16, 2021
May 3, 2019 35414823Z RESOLVE CLASS - 2 FAILURE TO SECURE/SUPPORT RACEWAYS/CABLE ASSEMBLIES/BOXES/CARD BOARDS/FITTING. OBSERVED IN REAR COURTYARD RACEWAYS SU... $0 $0 Jul 19, 2019
May 3, 2019 35414822R RESOLVE CLASS - 2 FAILURE TO PROVIDE GROUND FAULT CIRCUIT INTERRUPTER(GFCI)PROTECTION. OBSERVED ON 2ND,3RD,& 5TH FLOORS DEFECTIVE & IMN... $1,200 $0 Jul 19, 2019
May 22, 2018 32096893Y RESOLVE CLASS - 2 50A-B. AS PER CLASS 2 (B254) 28-301.1, FAILURE TO MAINTAIN. (50A)BOILER/TANK ROOM USED FOR STORAGE OF COMBUSTIBLE MAT... $312 $0 Jul 6, 2018
Apr 20, 2017 35252977M RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3;27-345. NOTED: FIRE STOP MISSINF IN ... $250 $0 Jun 16, 2017
Apr 20, 2017 35271656P RESOLVE CLASS - 2 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT MATERIALS,APPARATUS,DEVICE,APPLIANCE OR WIRING IN USE.OBSERVED EMT ... $400 $0 Sep 1, 2017
Apr 20, 2017 35252973P RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. OBSERVED ON 4/20/17@ ABOVE ADDRESS GAS PIPE IN BASEMENT NOT SUPPOR... $250 $0 Jun 16, 2017
Dec 15, 2016 35214499J RESOLVE CLASS - 2 OCCUPANCY CONTRARY TO THAT OF BLDG DEPT RECORDS. AT CELLAR 1 SUPERS APT,BOILER & STORAGE NOW 2 OFFICE IN CELLAR C OF ... $1,200 $0 Feb 3, 2017
Dec 15, 2016 35222701Y RESOLVE CLASS - 2 WORK W/OUT A PERMIT. OBSERVED ON 12/15/16 @ ABOVE ADDRESS GAS PIPING TO LAUNDRY EQUIPMENT REMOVED W/OUT ANY PERMITS N... $0 $0 Feb 3, 2017
Dec 15, 2016 35222702X RESOLVE CLASS - 2 FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED. OBSERVED ON 12-15-16 PLUMBING & PC 107.4(2014 CODE)WORK REMOVE... $500 $0 Feb 3, 2017
Aug 13, 2013 35021495L RESOLVE CLASS - 2 SEC. EC 408.4. VIOLATION OF THE ELECTRICAL TECHNICAL STANDARDS. NINE PANELS HAVE NOT BEEN PROVIDED W/DIRECTORIES. AT ... $200 $0 May 9, 2014
Aug 13, 2013 35021491Y RESOLVE CLASS - 2 FAILURE TO PROTECT CONDUCTORS AGAINST OVERCURRENT PER EC. ELECTRICAL SERVICE SWITCH 400A FUSES ON 2 1/0 AWG WIRED. @ ... $1,200 $0 May 9, 2014
Aug 13, 2013 35021493H RESOLVE CLASS - 1 VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS. SERVICE SWITCH NOT LOCATED AT CLOSEST POINT OF ENTRY INTO BLDG.... $400 $0 May 9, 2014
Aug 13, 2013 35021494J RESOLVE CLASS - 3 FAILURE TO CLOSE UNUSED OPENINGS (KNOCKOUTS) IN PANELS AND SEVICE EQUIPT. KO SEALS NOT PROVIDED TO CLOSE KNOCKOUT HOL... $150 $0 May 9, 2014
Aug 13, 2013 35021496N RESOLVE CLASS - 1 FAILURE TO PROPERLY GROUP/LABEL DISCONNECTS. 400 AMP SERVICE SWITCH NOT IDENTIFIED AS SUCH. AT 11:55AM OBSERVED IN EL... $250 $0 May 9, 2014
Aug 13, 2013 35021497P RESOLVE CLASS - 1 UNAPPROVED,UNSAFE,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT APPARATUS,MATERIALS,DEVICES,APPLIANCES AND WIRING IN USE. 20... $400 $0 May 9, 2014
Aug 13, 2013 35021499Z RESOLVE CLASS - 1 SEC. EC 320.40. VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS. ARMORED CABLE NOT PROPERLY TERMINATED INTO TOP ... $400 $0 May 9, 2014
Aug 13, 2013 35021489P RESOLVE CLASS - 2 FAILURE TO PROPERLY SECURE/SUPPORT ELECTRICAL METALLIC TUBING (EMT). (EMT) ELECTRICAL METALLIC TUBING IN SERVICE ROOM... $250 $0 May 9, 2014
Aug 13, 2013 35021498R RESOLVE CLASS - 1 SEC. EC 110.14A. VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS 400 AMP FUSED SERVICE SWITCH CONDUCTOR (LUGS) N... $0 $0 May 9, 2014