2290-2300 Sedgwick Avenue, Bronx • Block 03225 • Lot 0148

34 records

Violations issued by the Department of Buildings.

Issued Violation Type Category Description Disposed
Sep 23, 2025 RW20704JL C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE AT THE TIME OF INSPECTION,OBSERVED THAT A STONE RW IS LEANING INWARD A T EXP3 HAS DISPLACED STONES,SPALLED STONES,VER...
Oct 16, 2024 00068 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V*-DOB VIOLATION - DISMISSED FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION Jul 24, 2026
Aug 21, 2024 00074 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V*-DOB VIOLATION - DISMISSED FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION Jul 24, 2026
Nov 3, 2022 00043 BENCH-FAILURE TO BENCHMARK NONE V*-DOB VIOLATION - DISMISSED FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 Jan 30, 2023
Aug 3, 2022 00097 BENCH-FAILURE TO BENCHMARK NONE V-DOB VIOLATION - ACTIVE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Jun 2, 2022 00287 BENCH-FAILURE TO BENCHMARK NONE V-DOB VIOLATION - ACTIVE FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
May 19, 2022 22-01468 C-CONSTRUCTION OTHER OPTIONAL V-DOB VIOLATION - ACTIVE 30 FEET OF SHED IS LEANING SHED MEMBERS WAS DISPLACED, STRUCK BY CAR.
Feb 19, 2022 909820 FISPHAZ-HAZARDOUS CONDITION (FACADE) FACADE REQUIRED V*-DOB VIOLATION - DISMISSED CYCLE 9A UNSAFE REPORT FILED Mar 22, 2022
Feb 19, 2022 910318 FISPHAZ-HAZARDOUS CONDITION (FACADE) FACADE REQUIRED V-DOB VIOLATION - ACTIVE CYCLE 9A UNSAFE REPORT FILED
Jul 21, 2021 00203 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V*-DOB VIOLATION - DISMISSED FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION Jan 5, 2023
Jan 18, 2021 9027/696854 E-ELEVATOR ELEVATORREQUIRED V-DOB VIOLATION - ACTIVE
Sep 2, 2020 02362 AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE V*-DOB VIOLATION - DISMISSED FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION Oct 8, 2020
Jan 20, 2020 9027/669362 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Dec 16, 2022
Oct 1, 2019 00288 RWNRF-RETAINING WALL NONE V*-DOB VIOLATION - DISMISSED FAILED TO FILE CYCLE 1 TECHNICAL REPORT BY 12/31/2018 PER RCNY 103-09 Sep 15, 2025
Jan 19, 2019 9027/641990 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Feb 26, 2020
May 31, 2018 00472 FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED V-DOB VIOLATION - ACTIVE FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
Jan 16, 2018 9027/620629 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Feb 26, 2020
Jan 14, 2016 9027/560734 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Oct 17, 2017
Jul 22, 2015 9027/550048 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Oct 21, 2015
Jun 6, 2013 9027/472266 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Dec 11, 2013
Jan 31, 2013 00968 FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED V-DOB VIOLATION - ACTIVE FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012
Feb 16, 2012 9027/421070 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Jun 4, 2013
Dec 13, 2011 06334 LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED V*-DOB VIOLATION - DISMISSED VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT Jan 9, 2012
Mar 16, 2011 9027/376738 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Jul 13, 2013
Jul 27, 2010 9027/346346 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Oct 28, 2010
Nov 5, 2009 9027/322846 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Oct 28, 2010
Sep 25, 2008 9444/278337 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Oct 28, 2010
Jan 2, 2008 9444/232263 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Oct 28, 2010
Feb 25, 2004 9013/293072 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved Apr 29, 2005
Apr 29, 1999 9013/206883 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved 2P722 Apr 29, 2005
Aug 29, 1995 20194 LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED V*-DOB VIOLATION - DISMISSED Mar 5, 2002
Jun 9, 1994 05424 LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED V*-DOB VIOLATION - DISMISSED Mar 5, 2002
May 17, 1993 05951 LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED V*-DOB VIOLATION - DISMISSED Mar 5, 2002
Aug 26, 1988 14457/1 E-ELEVATOR ELEVATORREQUIRED V*-DOB VIOLATION - Resolved (51) PORT NAME OF RESPONSIBLE MAINTENANCE COMPANY IN MOTOR ROOM ( 52)PROVIDE CAPACITY PLATE (53) PROPERLY LOCATE MAIN... Feb 1, 1991