| Aug 7, 2026 | 39199808R | ACTIVE | CLASS - 2 | ATOI, OBSERVED PERMIT # X01387215-I1-LA, EXPIRED ON 07/01/2026, POSTED ON GLASS NEAR FRONT ENTRY DOOR. PERMITS MUST B... | $300 | $300 | Oct 16, 2026 |
| Apr 23, 2026 | 39185808J | ACTIVE | CLASS - 2 | REPLACE OR SECURE GIBS WHERE NEEDED. (2.11.11.5.7). MISSING CAB MIRROR (NYC BC 3001.2). REPAIR DAMAGED 1ST FLOOR HOIS... | $312 | $312 | Jul 31, 2026 |
| Nov 14, 2025 | 39167040M | ACTIVE | CLASS - 2 | CLASS 2 ITEMS: IN-CAR COMMUNICATION INOPERATIVE. CATEGORY 5 TEST TAG EXPIRED. PROVIDE KEYS (40M7) TO PERFORM AN COMPL... | $625 | $0 | May 29, 2026 |
| Oct 9, 2025 | 35717717N | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTED:OBSERVED AT EXP 1(W.ELEV)CRACKED BRICK FACADE AT... | $5,030 | $5,030 | Aug 4, 2026 |
| Mar 7, 2025 | 35716753X | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED AT EXP #1 WEST (1... | $5,000 | $5,000 | May 16, 2025 |
| Jan 6, 2025 | 38275597L | RESOLVE | CLASS - 1 | 97-X-17, 42-M-7. 97-X-17=ENTIRE DEVICE INOPERATIVE UPON INSPECTION THEDEVICE IS FOUND TO BE OUT OF SERVICE CREATING A... | $3,125 | $3,125 | Mar 21, 2025 |
| Dec 16, 2024 | 39133010X | RESOLVE | CLASS - 1 | RESPONDING. TO A 311 ELEVATOR COMPLAINT,UPON INSPECTION, CEASE USE VIOLATION ISSUED FOR. MISSING CAR FLOOR SELECTOR S... | $1,250 | $1,250 | Feb 21, 2025 |
| Jul 11, 2024 | 35681837X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING FACADE AND APPURTENANCES. OBSERVED BUILDING PARAPET WALL DAMAGED/HANGING MORTAR JOINTS A... | $2,500 | $2,500 | Feb 10, 2025 |
| May 8, 2024 | 39113778P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. ELEVATOR SERVICE TO THE BASEMENT DISABLED DUE TO A MALFUNCTION... | $625 | $0 | Aug 23, 2024 |
| Dec 17, 2022 | 39075856R | RESOLVE | CLASS - 1 | CEASE USE VIOLATION ISSUED, RESPONDING TO A ELEVATOR 311 COMPLAINT, UPON INSPECTION CEASE VIOLATION WAS FOUND, ITEMS ... | $1,250 | $0 | Mar 3, 2023 |
| Sep 14, 2022 | 39070071Y | RESOLVE | CLASS - 1 | CLASS 1 RECURRING VIOLATION ISSUED ,DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN SERVICE PRESENT IN CONTROLLER... | $0 | $0 | Feb 8, 2023 |
| Aug 3, 2022 | 39067278Y | RESOLVE | CLASS - 1 | DEVICE OUT OF SERVICE IN BETWEEN THE LOBBY AND 1ST FLOOR. THIS IS THE ONLY ELEVATOR IN THE BUILDING. RESTORE TO SERVI... | $1,250 | $0 | Sep 30, 2022 |
| Apr 19, 2022 | 39060617H | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED , DLM IMPROPERLY INSTALLED ON THIS DEVICE, NO FIREMAN SERVICE PRESENT IN CONTROLLER. INSTALL... | $1,563 | $0 | Jan 27, 2023 |
| Dec 2, 2021 | 39052145Z | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED, DLM IMPROPERLY INSTALLED ON THIS DEVICE, NO FIREMAN SERVICE PRESENT IN CONTROLLER. INSTALL ... | $3,155 | $0 | Mar 18, 2022 |
| Sep 14, 2021 | 39047474N | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED, NO FIRE SERVICE WAS INSTALL IN CONTROLLER, AS PER CODE FIRE MAN SERVICE AS TO WORK WITH DLM... | $1,250 | $0 | Dec 17, 2021 |
| Jan 14, 2021 | 39034886R | RESOLVE | CLASS - 2 | CLASS 2 VIOLATION ITEMS ARE 1/ FIREMAN SERVICE AND ALTERATIONS REMEDY; AS PER 2.27.3.3.6 OF THE 2014 NYCBC. 2/ IN CAR... | $0 | $0 | Mar 5, 2021 |
| Jan 2, 2020 | 39015177K | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED FOR NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12. OF APPENDIX... | $1,250 | $0 | Feb 21, 2020 |
| Sep 11, 2019 | 38271041H | RESOLVE | CLASS - 1 | (CEASE USE-5A10,58Y12)(56Y2,2X7,100M7,8V1,68M7)5A10:DOOR ZONE RESTRICTOR HAS BEEN RENDERED INOPERATIVE.THIS IS A SAFE... | $3,125 | $0 | Nov 22, 2019 |
| Nov 20, 2018 | 38266557M | RESOLVE | CLASS - 2 | 80B14,75I10,40P16. 80B10-RMDY SHORTEN COUNTERWEIGHT HOPES. SO COUNTERWEIGHT MAKES RUNBY (HT); 75I10-RMDY REPAIR COUNT... | $625 | $0 | Feb 1, 2019 |
| Apr 17, 2018 | 38262635K | RESOLVE | CLASS - 1 | 97X17, 68B07,68B07,40Y02. 97X17-RETURN TO SERVICE ONLY ELEVTOR IN THE BUILDING IS OUT OF SERVICE. REPAIR ELEVATOR AND... | $1,250 | $0 | Jun 1, 2018 |
| Dec 7, 2017 | 38260052J | RESOLVE | CLASS - 2 | 97X10. REPAIR DEVICE & RESTORE DEVICE TO SERVICE. | $0 | $0 | Feb 2, 2018 |
| Oct 10, 2017 | 38255711H | RESOLVE | CLASS - 2 | 20I11,59E1,58H10,56H10. | $530 | $0 | Dec 15, 2017 |
| Sep 19, 2017 | 38257580X | RESOLVE | CLASS - 1 | CU-05A10,CU-56X10; 60Q03,59M07. 05A10- DOOR RESTRICTOR TAMPERED OR ALTERED (REPAIR) THIS IS A SAFETY ITEM TO ENSURE P... | $1,000 | $0 | Nov 17, 2017 |
| Aug 3, 2016 | 38244587X | RESOLVE | CLASS - 2 | 59U15,68B07,70O02,56Y02,56Y13,70P16. NO TAG STATING DATE OF ANNUAL BRAKE MAINTENANCE, THE MAINTENANCE LOG IS LAST YEA... | $250 | $0 | Sep 30, 2016 |
| Jan 12, 2016 | 38240560H | RESOLVE | CLASS - 1 | 40P07,37W06,37M07,37M17. 40P07-ELEVAOTR IS OUT OF SERVICE (RESTORE TO SERVICE); 37W06-DOOR WAS UNLOCKED (SECURED); 37... | $1,000 | $0 | Mar 4, 2016 |
| Oct 28, 2015 | 38238789N | RESOLVE | CLASS - 2 | 42L10,40M07,70O02. 42-SELECTOR TAPE MAKING ALOUD NOISE REPAIR; PROVIDEKEYS FOR; 40-MACHINE ROOM SO A COMPLETE INSPECT... | $250 | $0 | Dec 18, 2015 |
| Feb 4, 2015 | 38234886R | RESOLVE | CLASS - 1 | 97X10 ENTIRE DEVICE HAS BEEN OUT OF SERVICE ON SIX STORY BLDG UNDER COMMISSIONER.CEASE USE ORDER,MUST REPAIR OR CORRE... | $2,500 | $0 | Apr 3, 2015 |
| Jan 16, 2015 | 38234741X | RESOLVE | CLASS - 1 | 16Q03,72D06,40Q03,42E10,56Y10,40O02,81M07,70O02,99BB05,68M07,100M07. 16-PROVIDE GUARDS TO CLOSE GAP BETW CAR AND HOST... | $1,000 | $0 | Mar 6, 2015 |
| Jan 2, 2015 | 38234565X | RESOLVE | CLASS - 1 | 16Q03,72D06,40Q03,42E10,56Y10,40O02,81M07,70O02,99BB05. 16-PROVIDE SIGHT GUARDS TO CLOSE GAP BETWEEN CAR AND HOISTWAY... | $1,000 | $0 | Feb 20, 2015 |
| Sep 17, 2014 | 38233137P | RESOLVE | CLASS - 2 | 12Q03,37T07,39O02,40O02,52M07,56Y13,60X10,60Q03,61T07,67M07,68M07,69M07,70O02,72M07,100M07. 37T07-PROVIDE SIGN FOR OV... | $0 | $0 | Nov 7, 2014 |
| Aug 21, 2014 | 35080223H | RESOLVE | CLASS - 2 | FAIL TO COMPLY W/THE COMM'S ORDER TO FILE C OF C W/DOB FOR ECB VIOLATION #35090766N.REM:FILE C OF C. | $400 | $0 | Dec 5, 2014 |
| Jun 24, 2014 | 34972328L | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OFCORRECTION W/ THE DEPT. OF BLDG FOR NOTICE OF V... | $800 | $0 | Nov 28, 2014 |
| Apr 5, 2014 | 35090767P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC1008.1 (27-371(JJ) NO... | $250 | -$312 | May 30, 2014 |
| Apr 5, 2014 | 35090766N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDGS WALL(S) APPURTENANCES NOTE AT REAR OF PROPERTY A SECTION OF THE NATURAL STONE AND MASONRY R... | $1,000 | $0 | May 30, 2014 |
| Jan 5, 2007 | 38163261L | RESOLVE | Non-Hazardous | 15I10/02X10/31H10/55Y13/58Y02/41E10/08M10/83O02.2X10-NOT WORKING FOR EMERGENCY STOP SWITCH.41E10-SELECTOR TAPE SHEAVE... | $0 | $0 | Feb 23, 2007 |
| Jun 3, 2005 | 38153104Z | RESOLVE | Non-Hazardous | 21R#. 21-WORKING W/O PERMIT NEW INTERLOCKS FROM 1 TO 6 FILE TO OBTAIN PERMIT FROM THE DEPT OF BLDGS ALSO IMPROPER WIR... | $0 | $0 | Jul 22, 2005 |
| Jan 22, 2003 | 38134964P | RESOLVE | Non-Hazardous | 52 BED PLATE FULL OF OIL, REPAIR LEAK FROM PULLING. 80 TOEGUARD. 81 RULE 1002.3 ANSIA17D- 88 PROVIDE NAME OF FIRE WHO... | $0 | $0 | Mar 7, 2003 |
| Jul 13, 2000 | 38106928J | RESOLVE | Non-Hazardous | 8V1 22L6 37Q3 | $0 | $0 | Aug 25, 2000 |
| Aug 6, 1998 | 38077419L | RESOLVE | Non-Hazardous | 50Y,47H,46H,14M,17L,15L, 14-GLASS MISSING IN FRAME. 13-CAR NEED BRAKET 3RD FL & AND GIBS ON EACH DOOR W/FIRE TABS. | $0 | $0 | Sep 25, 1998 |
| Sep 2, 1997 | 38063185K | RESOLVE | Non-Hazardous | 39H,28J,08V,08P,31D 08-RESTORE TO SECOND FLOOR 31-SECURE WIRES IN MOTOR ROOM. | $100 | $0 | Oct 24, 1997 |