Maintenance code violations
1932 Hennessy Place, Bronx • Block 03228 • Lot 0090
126 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Oct 6, 2021 | A | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SWITCH COVER IN THE 1st ROOM FROM EAST LOCATED AT APT 2, 2... | 2 | Jan 9, 2022 |
| Oct 6, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR LOCK IN THE ENTRANCE LOCATED AT APT 2, 2nd STORY, 1st... | 2 | Nov 10, 2021 |
| Oct 6, 2021 | C | NOTICE OF ISSUANCE SENT TO TENANT | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... | 2 | Nov 1, 2021 |
| Oct 6, 2021 | C | NOTICE OF ISSUANCE SENT TO TENANT | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd S... | 2 | Nov 1, 2021 |
| Oct 6, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 2, 2nd STO... | 2 | Nov 10, 2021 |
| Oct 6, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SWITCH COVER IN THE 2nd ROOM FROM EAST LOCATED AT APT 2, 2nd STORY, 1... | 2 | Nov 10, 2021 |
| Sep 15, 2021 | C | DEFECT LETTER ISSUED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT PUBLIC HALL, 1st STORY | — | Oct 11, 2021 |
| Sep 15, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT SWITCH AT NORTH WALL AT PUBLIC HALL, 1st STORY | — | Oct 20, 2021 |
| Sep 15, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING AT PUBLIC HALL, 1st STORY | — | Oct 20, 2021 |
| Aug 20, 2021 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT NORTH WALL... | — | Nov 23, 2021 |
| Aug 20, 2021 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT NORTH WALL AT PUBLIC HALL... | — | Nov 23, 2021 |
| Aug 20, 2021 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT NORTH WALL... | — | Nov 23, 2021 |
| Aug 20, 2021 | C | NOTICE OF ISSUANCE SENT TO TENANT | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM WE... | 2 | Sep 15, 2021 |
| Aug 20, 2021 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ROTTED WOOD BASE AT SINK CABINET IN ... | 2 | Nov 23, 2021 |
| Aug 20, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE KITCHEN LOCATED AT APT 2, 1... | 2 | Sep 24, 2021 |
| Aug 20, 2021 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT VERTIBULE. | — | Nov 23, 2021 |
| Aug 20, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET COVER PLATE AT WEST WALL IN THE 3rd ROOM FROM EAST ... | 2 | Sep 24, 2021 |
| Aug 20, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET COVER PLATE AT NORTH WALL AND SWITCH OUTLET COVER P... | 2 | Sep 24, 2021 |
| Aug 20, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST... | 2 | Sep 24, 2021 |
| Aug 20, 2021 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 2, 1st STORY, 1st ... | 2 | Sep 24, 2021 |
| Aug 20, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MORTISE LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT 2, 1s... | 2 | Aug 26, 2021 |
| Aug 20, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE HANDRAIL AT NORTH WALL AT PUBLIC HALL STAIRS, 1st STORY | — | Aug 26, 2021 |
| Aug 20, 2021 | C | NOT COMPLIED WITH | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... | — | Aug 26, 2021 |
| Aug 20, 2021 | A | NOT COMPLIED WITH | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Nov 23, 2021 |
| Aug 20, 2021 | A | NOT COMPLIED WITH | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Nov 23, 2021 |
| Aug 20, 2021 | A | NOT COMPLIED WITH | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... | — | Nov 23, 2021 |
| Aug 20, 2021 | A | NOT COMPLIED WITH | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED... | — | Nov 23, 2021 |
| Aug 20, 2021 | A | NOT COMPLIED WITH | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | Nov 23, 2021 |
| Aug 20, 2021 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT... | — | Sep 24, 2021 |
| Aug 20, 2021 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT NORTH WALL AT VERTIBULE. | — | Nov 23, 2021 |
| Aug 9, 2021 | C | NOV SENT OUT | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 2, 1st STORY, 1st ... | 2 | Sep 4, 2021 |
| Aug 9, 2021 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND WEST WALL IN ... | 2 | Nov 12, 2021 |
| Aug 9, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER PLATE AT ELECTRICAL OUTLETS AT NORTH AND SOUTH WALL IN THE 2nd ... | 2 | Sep 13, 2021 |
| Aug 9, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD DOOR IN THE ENTRANCE LOCATED AT APT 2, 1st STORY, 1s... | 2 | Aug 15, 2021 |
| Aug 9, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK ASSEMBLY ON DOOR IN THE ENTRANCE LOCATED AT APT 2, 1s... | 2 | Aug 15, 2021 |
| Aug 9, 2021 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 2 | Sep 4, 2021 |
| Aug 9, 2021 | C | NOTICE OF ISSUANCE SENT TO TENANT | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st S... | 2 | Sep 4, 2021 |
| Aug 9, 2021 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 2 | Sep 13, 2021 |
| Aug 9, 2021 | B | NOV SENT OUT | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY... | 2 | Sep 13, 2021 |
| Apr 2, 2021 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 6, 2021 |
| Mar 22, 2021 | A | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT SWITCH COVER AT THE SOUTH WALL IN THE 1s... | 2 | Jun 25, 2021 |
| Mar 22, 2021 | A | NOT COMPLIED WITH | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Jun 25, 2021 |
| Mar 22, 2021 | A | NOT COMPLIED WITH | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND T... | — | Jun 25, 2021 |
| Mar 22, 2021 | A | NOT COMPLIED WITH | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... | — | Jun 25, 2021 |
| Mar 22, 2021 | A | NOT COMPLIED WITH | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED... | — | Jun 25, 2021 |
| Mar 22, 2021 | C | NOT COMPLIED WITH | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... | — | Mar 28, 2021 |
| Mar 22, 2021 | A | NOT COMPLIED WITH | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR... | — | Jun 25, 2021 |
| Mar 22, 2021 | A | NOT COMPLIED WITH | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... | — | Jun 25, 2021 |
| Mar 22, 2021 | A | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET COVER AT THE NORTH WALL IN THE 1st ROOM... | 2 | Jun 25, 2021 |
| Mar 22, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN T... | 2 | Apr 26, 2021 |