| Mar 18, 2026 | 35722196N | ACTIVE | CLASS - 2 | RE-ISSUE #35691995K. EXIT DOOR NOT SELF-CLOSING. NOTED: ON 1ST FLR-"EXIT 2" AND "EXIT 6"(EXTERIOR DOORS) DO NOT SELF-... | $1,562 | $0 | May 8, 2026 |
| Mar 18, 2026 | 35722197P | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLINAT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS P... | $1,250 | $0 | May 8, 2026 |
| Apr 2, 2025 | 35691995K | ACTIVE | CLASS - 2 | REISSUE ECB#35678965N EXIT DOOR NOT SELF CLOSING.NOTED AT 1ST FL EXIT 5,STAIR D GYM RM 111,2ND FL CAFETERIA DOORS ARE... | $1,562 | $0 | Jul 18, 2025 |
| Apr 2, 2025 | 35691996M | RESOLVE | CLASS - 2 | REISSUE#35678964L EMERGENCY SIGNS AT ELEVATOR CALL STATIONS MISSING DEFECTIVE OR NON COMPLIANT WITH SECTION REQUIREME... | $1,562 | $0 | Jul 18, 2025 |
| Apr 5, 2024 | 35678965N | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVEDAT 1 FLR.-CAFETERIA EXIT DOOR #6 IS NOT WORKING... | $625 | $0 | May 17, 2024 |
| Apr 5, 2024 | 35678964L | RESOLVE | CLASS - 2 | RE-ISSUE #35665321P-EMERGENCY SIGNS AT ELEVATOR CALL STATIONS MISSING,DEFECTIVE, OR NON-COMPLIANT WITH SECTION REQUIR... | $1,562 | $0 | May 17, 2024 |
| Mar 2, 2023 | 35665321P | RESOLVE | CLASS - 2 | REISSUE#35651075L EMERGENCY SIGNS AT ELEVATOR CALL STATION MISSING,DEFECTIVE OR NON-COMPLIANT WITH SECTION REQUIREMEN... | $1,562 | $0 | Jun 16, 2023 |
| Mar 2, 2023 | 35665322R | RESOLVE | CLASS - 2 | 28-301.1 REISSUE#35548174L UNLAWFUL PLACEMENT OF FURNISHINGS,DECORATIONS OR OTHER OBJECTS AT EXITS THAT OBSTRUCT ACCE... | $1,250 | $0 | Jun 16, 2023 |
| Mar 21, 2022 | 35651075L | RESOLVE | CLASS - 2 | REISSUE#35548171X.EMERGENCY SIGN ELEVATOR CALL STATIONS MISSING.DEFECTION,NON-COMPLIANT,EMERGENCY SIGNS AT ELEVATOR S... | $1,562 | $0 | Jul 1, 2022 |
| Mar 21, 2022 | 35644599R | RESOLVE | CLASS - 2 | REISSUE#35548174L FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTE AT THE STAIRCASE THAT GOES TO THE ROOF F... | $1,562 | $0 | Jul 1, 2022 |
| Mar 9, 2021 | 35548174L | RESOLVE | CLASS - 2 | 28-301.1-UNLAWFUL PLACEMENT OF FURNISHINGS DECORATION ON OTHER OBJECT AT EXIT THAT OBTRUCT ACCESS TO EGRESS FROM OR V... | $1,250 | $0 | Jun 18, 2021 |
| Mar 9, 2021 | 35548171X | RESOLVE | CLASS - 2 | REISSUE #35381452K EMERGENCY SIGN AT ELEVATOR STATION MISSING OR NON COMPLIANT WITH SECTION REQUIRMENT NO EMERGENCY S... | $1,562 | $0 | Jun 18, 2021 |
| Mar 9, 2021 | 35548172H | RESOLVE | CLASS - 2 | REISSUE #35381451Z FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AT BULKHEAD STAIRCASE B WATER DAMAGE TO CEIL... | $1,562 | $0 | Jun 18, 2021 |
| Mar 9, 2021 | 35548173J | RESOLVE | CLASS - 2 | EXIT DOOR NOT SELF CLOSING NOTED EXT #B #9 AT FIRST FLOOR AND F4 AT ROOF LEVEL ARE NOT SELF CLOSING REPAIR OR REPLACE... | $625 | $0 | Jun 18, 2021 |
| Jan 28, 2019 | 35381451Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: @BULKHEAD STAIRASE WATER DAMAGE TO CEILING DUE TO WATER PENETR... | $0 | $0 | Apr 19, 2019 |
| Jan 28, 2019 | 35381452K | RESOLVE | CLASS - 2 | REISSUE: #35329218Y EMERGENCY SIGNS AT ELEVATOR STATION MISSING DEFECTIVE ON NON-COMPLIANT W/SECTION REQUIREMENTS AT ... | $0 | $0 | Apr 19, 2019 |
| Apr 17, 2018 | 35329221P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLAINT MANNER.NOTED @1ST FL,ELECTRICAL ROOM, ILLEGAL STORAGE CLEANING MATERIALS &... | $0 | $0 | Jun 29, 2018 |
| Apr 17, 2018 | 35329219X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN NLDG IN CODE-COMPLAINT MANNER.NOTED:THE CLOSE COMPLETELY AFTER USE @RM #108,206 & STAIRCASE (D) @... | $0 | $0 | Jun 29, 2018 |
| Apr 17, 2018 | 35329220N | RESOLVE | CLASS - 2 | 28-301.1 FAILURE TO PROVIDE VENTILATION TO GAS METER ROOM PER P 115.6 (1968 CODE),FGC APPENDIX E (E4) (2014 CODE)NOTE... | $0 | $0 | Jun 29, 2018 |
| Apr 17, 2018 | 35329217M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER NOTES:@BILKHEAD STAIRCASE (B),WATER DAMAGED TO CEILING DUE TO WATER... | $0 | $0 | Jun 29, 2018 |
| Apr 17, 2018 | 35329216K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLAINT MANNER:LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES & PUBLIC CORRI... | $0 | $0 | Jun 29, 2018 |
| Apr 17, 2018 | 35329218Y | RESOLVE | CLASS - 2 | EMERGENCY SIGNS @ELEVATOR CALL STATIONS MISSING DEFECTIVE OR NON-COMPLAIN W/SECTION REQUIREMNTS.NOTED:@1ST,2ND,3RD FL... | $0 | $0 | Jun 29, 2018 |
| Jan 23, 2018 | 35311509Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER: LACK OF EMERGENCY LIGHTING FOR EXITS, EXIT DISCHARGES AND PUBLIC C... | $0 | $0 | Apr 20, 2018 |
| Mar 17, 2016 | 35171544M | RESOLVE | CLASS - 2 | REISSUED #35146804P FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER. PROVIDE REQUIRED CORRIDOR WIDTH PER BC1016... | $0 | $0 | Jun 17, 2016 |
| Jul 13, 2015 | 35146804P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.PROVIDE REQUIRED CORRIDOR WIDTH PER BC 1016.2;27-369 RE-ISSUE NOV#3... | $0 | $0 | Oct 30, 2015 |
| Apr 3, 2013 | 35013088Y | RESOLVE | CLASS - 2 | REISSUE #34981437P. CORRIDOR WIDTH REDUCED BY STORAGE OF CABINETS, CH AIRS, TABLES IN 1ST FL HALL. REMEDY: PROVIDE PR... | $0 | $0 | May 17, 2013 |
| Jun 26, 2012 | 34981438R | RESOLVE | CLASS - 2 | MISSING FIRE STOPPING. AT CORRIDOR ADJACENT TO CUSTODIANS OFFICE MISSING DROP CEILING TILES EXPOSING UNPROTECTED FLR ... | $0 | $0 | Sep 21, 2012 |
| Jun 26, 2012 | 34981437P | RESOLVE | CLASS - 2 | PARTIAL OBSTRUCTION. AT 1ST FLR PARTIAL OBSTRUCTION OF CORRIDOR WITH CABINETS CHAIRS & TABLES. BOXES ABOVE CABINETS P... | $0 | $0 | Sep 21, 2012 |
| Jun 26, 2012 | 34981439Z | RESOLVE | CLASS - 2 | DOORS NOT SELF CLOSING. AT FIRST FLR SMOKE DOORS WITH KICK STOPS INSTALLED & CAFETERIA DOOR WITH RUG & VARIOUS OBJECT... | $0 | $0 | Sep 21, 2012 |
| Jul 22, 2011 | 34918621N | RESOLVE | CLASS - 1 | REISSUE:34770188N EXIT PASSAGEWAY @ STAIR 'C' IS PARTIALLY OBSTRUCTED BY CABINETS ON THE 3 FLR LEVEL.(HAZARDOUS).REM:... | $0 | $0 | Sep 16, 2011 |
| Jun 29, 2010 | 34855901M | RESOLVE | CLASS - 2 | NO FRESH AIR VENT IN GAS METER ROOM ALSO NOTE: BOILER ROOM FRESH AIR VENT HAS BEEN COVERED. REMEDY: PROVIDE FRESH AIR... | $0 | $0 | Sep 17, 2010 |
| Jun 29, 2010 | 34855902Y | RESOLVE | CLASS - 2 | HOLE IN CONCRETE BLOCK WALL OF GAS METER ROOM @ PIPE PENETRATION REMEDY: PROVIDE / MAINTAIN FIRE STOPPING | $0 | $0 | Sep 17, 2010 |
| Jun 29, 2010 | 34855903X | RESOLVE | CLASS - 2 | GAS METER ROOM IS BEING USED FOR STORAGE OF FIRE EXTINGUISHERS, BOXES OF LIGHT BULBS ETC. REMEDY: REMOVE STORAGE FROM... | $0 | $0 | Sep 17, 2010 |
| Jun 29, 2010 | 34855900K | RESOLVE | CLASS - 2 | 2ND FL GYM ENTRANCE DOOR NOT CLOSING STWY "B" DOOR LOCKED REMEDY: REPAIR / REPLACE DOORS | $0 | $0 | Sep 17, 2010 |
| Mar 12, 2009 | 34770189P | RESOLVE | CLASS - 2 | REISSUE: 34592741K CLASSROOMS ON THE 2ND & 1ST FLR IS MISSING DOOR CLOSERS. REMEDY: PROVIDE DOOR CLOSERS. | $0 | $0 | May 15, 2009 |
| Mar 12, 2009 | 34770187L | RESOLVE | CLASS - 2 | SEC. 27-369 REISSUE: 34646996N CORRIDOR/HALLWAY IS PARTIALLY OBSTRUCTED BY FILE CABINETS LOCATED BY CLASSROOM 611 & 6... | $0 | $0 | May 15, 2009 |
| Mar 12, 2009 | 34770188N | RESOLVE | CLASS - 2 | SEC. BC1017.1 27-369 REISSUE: 34646995L EXIT PASSAGEWAY AT STAIRWAY 'C' (LIBRARY) ON THE 3RD FLR LEVEL IS PARTIALLY O... | $0 | $0 | May 15, 2009 |
| May 7, 2008 | 34646997P | RESOLVE | Hazardous | EXIT DOOR #7 IN THE CAF IS DEFECTIVE EXIT DOOR IS HITTING THE DOOR FRAME MAKING DOOR TO OPEN PROPERLY. REMEDY: REPAIR... | $0 | $0 | Jun 27, 2008 |
| May 7, 2008 | 34646996N | RESOLVE | Hazardous | REISSUE: 34592738J CORRIDOR PASSAGEWAY IS PARTIALLY BLOCK W/ TABLES & CHAIRS BY ROOM G15 & G15 ON THE 1ST FLR LEVEL. ... | $0 | $0 | Jun 27, 2008 |
| May 7, 2008 | 34646995L | RESOLVE | Hazardous | REISSUE: 34592839L EXIT PASSAGEWAY AT STAIRCASE EXIT "C" (LIBRARY) ON THE 3RD FLR, FLR LEVEL IS PARTIALLY OBSTRUCTED ... | $0 | $0 | Jun 27, 2008 |
| Aug 24, 2007 | 34592742M | RESOLVE | Hazardous | ROOF HAS BECOME POROUS & ALLOWING WATER TO ENTER THE BLDG CAUSING INTERIOR DAMAGES TO RM 210 & EXIT DOOR "B" ON THE 2... | $0 | $0 | Nov 16, 2007 |
| Aug 24, 2007 | 34592738J | RESOLVE | Hazardous | REISSUE:34523462Z CORRIDOR PASSAGEWAY IS LOCATED BY RM G11 & G15 ON THE 1ST FL LEVEL.REMEDY:REMOVE OBSTRUCTION. | $0 | $0 | Nov 16, 2007 |
| Aug 24, 2007 | 34592741K | RESOLVE | Hazardous | ALL CLASSROOM DOORS ARE MISSING DOOR CLOSERS LOCATED AT EVERY CLASSROOM ON EVERY FL 1-4 REMEDY:PROVIDE CLASSROOM DOOR... | $0 | $0 | Nov 16, 2007 |
| Aug 24, 2007 | 34592739L | RESOLVE | Hazardous | EXIT PASSAGEWAY STAIRWAY IS OBSTRUCTED LOCATED BY EXIT "C" (LIBRARY) ON 3RD FL LEVEL BY FILE CABINETS & BOOK SHELVES.... | $0 | $0 | Nov 16, 2007 |
| May 22, 2006 | 34523462Z | RESOLVE | Hazardous | REISSUE:34466840Z CORRIDOR PASSAGEWAY BEING BLOCKED W/TABLES,CHAIRS,FILE CABINETS LOCATED BY CLASSROOM G11 & G15 ON T... | $0 | $0 | Aug 18, 2006 |
| Feb 15, 2005 | 34466840Z | RESOLVE | Hazardous | EXIT PASSAGEWAY OR CORRIDOR REQUIRED WIDTH DECREASED BY OBSTRUCTION.NOTED:CLASSROOM 611 CORRIDOR BEING USED FOR TEACH... | $0 | $0 | Apr 22, 2005 |
| Feb 1, 2001 | 34270444M | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. EXPIRED PERMIT #200629089 EXPIRED 12/410/00. STOP ALL WORK......REMEDY: OBTAIN/RENEW PERMIT. | $0 | $0 | Mar 16, 2001 |
| Feb 1, 2001 | 34270443K | RESOLVE | Hazardous | FAILURE TO PROVIDE ADEQUATE PROTECTION FOR SIDEWALKS AND WALKWAYS DURING CONSTRUCTION OPERATIONS. IN THAT HAVING CONS... | $2,000 | $0 | Mar 16, 2001 |
| Jun 3, 1999 | 34206844P | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR. DEFECT IS: PARAPET WALL N/S CORNER OF BUILDING. IS CRACKED AND SEPARATING. HAZARDOUS CO... | $0 | $0 | Jul 23, 1999 |