ECB violations
West 230 Street, Bronx • Block 03256 • Lot 0200
28 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 2, 2025 | 35717707J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTED OBSERVED AT EXP.2(S.ELEV)MISSING MORTAR AT PARAP... | $5,000 | $5,000 | Dec 19, 2025 |
| Oct 2, 2025 | 35717708L | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:OBSERVED AT EXP 1(E.ELEV),EXP 2(S.ELEV)AND EXP 3(W.ELEV)OBJECTS... | $0 | $0 | Apr 16, 2026 |
| Oct 2, 2025 | 35717959X | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: OBSERVED AT EXP 1(E. ELEV), EXP 2(S. ELEV) AND EXP 3(W. ELEV)... | $625 | $625 | Apr 16, 2026 |
| Mar 4, 2025 | 35689995H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #2 SOUTH(1) S... | $5,000 | $5,000 | Feb 27, 2026 |
| Mar 4, 2025 | 35689996J | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAYS.-NOTE: AT TIME OF INSPECTION, I OBSERVED AT EXP #1 EAST, #2 SOUTH, #... | $2,500 | $2,500 | Feb 27, 2026 |
| Nov 29, 2021 | 39051780N | ACTIVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED RTS, UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT-OF-SERVICE CREATING A HAZARDOUS CONDITIO... | $1,250 | $0 | Jul 15, 2022 |
| Jun 26, 2021 | 39043512R | ACTIVE | CLASS - 1 | CLASS 1 VIOLATION NO FIRE SERVICE IN CONTROLLER REMEDY, FILE APPLICATION THEN INSTALL FIRE SERVICE TO WORK WITH DLM O... | $1,250 | $0 | Jun 24, 2022 |
| May 25, 2021 | 39041828Y | RESOLVE | CLASS - 1 | RESTORE DEVICE TO SERVICE SO THAT INSPECTION CAN BE MADE BY THIS DEPARTMENT. | $1,250 | $1,250 | Sep 3, 2021 |
| Jun 10, 2018 | 38263657X | RESOLVE | CLASS - 1 | CU-05A10; 55H08,57M07,58Y10,59BB05,67X10,70O02. 05A10-UPON INSPECTIONOF DEVICE IT WAS FOUND THAT THE ZONE RESTRICTOR ... | $1,250 | $0 | Aug 3, 2018 |
| May 8, 2015 | 38236207P | RESOLVE | CLASS - 2 | 56Y13,61T07,69R07,76M07,98U15,99U15,100M07. 61T07-PROVIDE COMPANY STICKER FOR MAIN LINE SWITCH BOX; 69R07-PROVIDE THE... | $0 | $0 | Jul 10, 2015 |
| Mar 9, 2015 | 38235205R | RESOLVE | CLASS - 2 | 67X10,41T07,70O02,71X10,16L10,05M10,40M07,39O02. 67-RESTORE EXISTING EMERGENCY (PHONE) IN ELEVATOR CAB;05-CAR DOOR RE... | $0 | $0 | May 1, 2015 |
| Jan 13, 2009 | 38200314X | RESOLVE | CLASS - 2 | 15I10.12Q03.39O02.56Y13.52O02.57Q03.45E10.21D06.70O02.57Q03.HOIST MOTOR LEAD WIRING 21D06 6 FL INTERLOCK | $250 | $0 | Mar 6, 2009 |
| Sep 5, 2007 | 38169508L | RESOLVE | Non-Hazardous | 38O02,38Q03,55Y02,59Q03,66O02,71Q03,86M05. 38-Q-03 INSTALL GUARD FOR LIGHT ON TOP OF CAR 55-Y-02 CLEAN UP OIL FROM MA... | $350 | $0 | Dec 7, 2007 |
| Feb 28, 2005 | 38151224Y | RESOLVE | Non-Hazardous | 08V10/58Y02/58Q07/85U05/15I10. 58Q07 - PROPERLY GUARD WIRING. 15-COVER MISSING | $0 | $0 | Apr 15, 2005 |
| Dec 14, 2004 | 38156637P | RESOLVE | Non-Hazardous | 83R# 83-R-#= ILLEGAL WORK IN PROGRESS, NEW WORM AND GEAR. FILE FOR APPLICATION AND OBTAIN PERMIT FROM DOB AND CALL FO... | $500 | $0 | May 6, 2005 |
| Dec 13, 2004 | 38150163P | RESOLVE | Non-Hazardous | 83X10/59P16 REPAIR AND RESTORE TO SERVICE SO A FULL INSPECTION COULD BE DONE BY THIS DEPARTMENT. | $180 | $0 | Jan 28, 2005 |
| Jul 6, 2004 | 38148103K | RESOLVE | Non-Hazardous | 41G11/59X11/55Y13/55O2/43H11/43H8/51H11/44Y2/85B11/25Q3/16B1/60T15/8V1/10M7/14I11/20R11/32O2/33O2/38O2/39O2/66O2/67O2... | $350 | $0 | May 6, 2005 |
| Oct 24, 2000 | 38109327H | RESOLVE | Non-Hazardous | 1#11,5#1, 9B7, 17M7, 57O2, 74X11. 1)NO BUZZING SOUND FOR STOP SWITCH, 5)BIG GAP ON CAR DOOR WHEN CLOSED, 9)PROVIDING ... | $350 | $0 | Nov 16, 2001 |
| Mar 23, 1999 | 38084916H | RESOLVE | Non-Hazardous | 30O2,25Q3,74M7,75M5,35P17,36P17,57O2. 74-PROVIDE COVER FOR SMOKE HOLEIN MOTOR RM ON FL. | $0 | $0 | May 14, 1999 |
| Nov 6, 1998 | 38081369Y | RESOLVE | Non-Hazardous | 08V01,11Q03,11X11,09H12,15R09,15L11,22D06,25Q03,28H11,30O02,22D02,350O2,46O02,50Y11,52Q03,75U05,17A12,05A12,10L12,.#1... | $0 | $0 | Jan 8, 1999 |
| Jun 1, 1998 | 38074750H | RESOLVE | Non-Hazardous | 75U,80Y,80Y,80X,17B,22D,51B,39H,35P,30O,03O,57O, | $800 | $0 | Jun 11, 1999 |
| Mar 21, 1998 | 38071250H | RESOLVE | Non-Hazardous | 75U50Y74O25M20X28B15I57O 50 Y-CLEAN UP OIL 74-0 CLEAN TOP OF CAR 25 M-REPLACE COVER 20 X REPAIR BUTTON CALL 15 I REPA... | $0 | $0 | May 8, 1998 |
| Nov 12, 1996 | 34139836H | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR NOTED: (1) THE MASONARY (BRICK) BOILER CHIMNEY AT ROOF IS BROKEN MISSING &DEFECTIVE (ADJ... | $175 | $0 | Jun 27, 1997 |
| Mar 20, 1996 | 38052575M | RESOLVE | Non-Hazardous | 73X,57O,35P,74O.73-RESTORE ELEV TO SERVICE 35-ACCESS TO MOTOR ROOM 74-CLEAN TOP OF CAR | $0 | $0 | Jul 12, 1996 |
| Apr 21, 1993 | 38033978N | RESOLVE | Non-Hazardous | 14M,50B,74B,35P,74O,74B,74B, (50) REMOVE NOISE FROM MAIN MACHINE (74) PROVIDE SUFFICIENT CAR LIGHTING. (74) CLEAN CAR... | $100 | $0 | Aug 5, 1993 |
| Mar 23, 1992 | 38023339H | RESOLVE | Non-Hazardous | 03M,03I,22D,35P,(03) PROVIDE CAPACITY PLATE IN CAB. (03)-REPAIR DAMAGED AIR VENT IN REAR OF CAR ENCLOSE ARE (35)- NO ... | $0 | $0 | May 22, 1992 |
| Sep 6, 1991 | 38013525M | RESOLVE | Non-Hazardous | 14M,35P,57O,74O,62M,05J,(74)CLEAN CAR TOP. (62)TOE GUARD MISSING (05)REMOVE GAP WHERE CAR DOOR MEETS STRIKER POST. | $0 | $0 | Feb 27, 1992 |
| Feb 19, 1991 | 38004359L | RESOLVE | Non-Hazardous | 40R,35P,14M,57O,74O 40-PERFORM 5YR. GN. TEST 35. ACCES TO MOTOR ROOM. 74-CLEAN TOP OF CAR. | $150 | $0 | May 14, 1992 |