Issued Violation Status Severity Description Penalty Balance due Hearing
May 20, 2026 39554329N ACTIVE CLASS - 2 AT THE TIME OF INSPECTION, I OBSERVED A SIDEWALK SHED NOT MAINTAIN AS PER CODE 3307.6.4.10 FOUNDING UNSTABLE STANDING... $2,400 $2,400 Feb 12, 2027
Apr 20, 2026 37036863K ACTIVE CLASS - 2 FAILURE TO FILE ACCEPTABLE CYCLE 8B AND 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITION DESCRIBED IN INITIAL FACA... $1,250 $1,250 Aug 21, 2026
Apr 2, 2026 39552497N RESOLVE CLASS - 2 AT THE TIME OF INSPECTION, I OBSERVED SIDEWALK SHED IN PLACE NOT IN CODE COMPLYING BC 3307.6.5.5 SIDEWALK SHED HAS RO... $2,400 $2,400 Jan 22, 2027
Apr 2, 2026 39552494H RESOLVE CLASS - 2 AT THE TIME OF INSPECTION OF A 6-STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE, DURING MY INSPECTION I NOTICED SI... $1,250 $1,250 Jan 22, 2027
Mar 17, 2025 39141743N ACTIVE CLASS - 2 FOUND A FEDERAL FST-150 STEMP BOILER IN TEMPORARY STATUES/AS PER DOB RECORDS PERMIT220290058 HAS NOT BEEN SIGNED OFF ... $1,250 $0 Oct 3, 2025
Oct 19, 2023 39097434Y RESOLVE CLASS - 3 FAILURE TO MAINTAIN, OBSERVED WINDOW A/C UNITS ON FLOORS 3 AND 4 ARE MISSING SUPPORT BRACKETS, REPAIR AND OR REPLACE;... $0 $0 Jan 19, 2024
Oct 6, 2023 39522433R RESOLVE CLASS - 2 AT TIME OF MY INSPECTION OF A SIDEWALK SHED AT A OCCUPIED 6 STORY BUILDING.UPON REVIEWING DEPARTMENT OF BUILDING RECO... $625 $0 Dec 15, 2023
Oct 6, 2023 39522434Z RESOLVE CLASS - 2 AT TIME OF MY INSPECTION OF A SIDEWALK SHED AT A 6 STORY BUILDING. SIDEWALK SHED IS NOT AS PER CODE IT IS MISSING NET... $1,250 $0 Apr 12, 2024
Oct 19, 2022 37023183Y RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... $1,250 $0 May 12, 2023
Apr 5, 2022 39059628P ACTIVE CLASS - 1 CLASS 1 VIOLATION ISSUED, DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN SERVICE PRESENT IN CONTROLLER. INSTALL ... $1,250 $0 Oct 26, 2022
Mar 2, 2022 35645916X RESOLVE CLASS - 2 FAILURE TO PROVIDE PEDESTRIAN PROTECTION.AT TIME OF MY INSPECTION OF A6 STORY OCCUPIED BUILDING WITH A SIDEWALK SHED ... $2,400 $2,400 Dec 6, 2022
Mar 2, 2022 35645917H RESOLVE CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT PERMIT EXPIRED AT TIME OF MY INSPECTION OF A 6 STORY OCCUPIED BUILDING WITH A SIDEWA... $0 $0 Dec 6, 2022
Oct 13, 2021 35635530Y ACTIVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.AS NOTED BUILDING HAS DAMAGED MORTAR JOINTS,STEP CRACK... $1,250 $0 Jan 7, 2022
Jun 1, 2021 37021644Z RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... $3,125 $0 Nov 12, 2021
Oct 15, 2018 37013744X RESOLVE CLASS - 2 FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... $1,250 $0 Jul 26, 2019
Apr 20, 2017 32088282P ACTIVE CLASS - 2 B254,36 36)AS PER (CLASS) 254,36 BURNER NOT REGISTERED AS PER DOB RECORDS.CORRECT ALL VIOLATIONS CONDITIONS AND SUBMI... $500 $0 Jun 30, 2017
Aug 16, 2016 38244920K RESOLVE CLASS - 1 05A10 CAB DOOR RESTRICTOR IS BEEN TAMPERED WITH (REPAIR) $0 $0 Dec 16, 2016
Aug 16, 2016 38244919N RESOLVE CLASS - 1 05A10,08J01,37M07,59D06,56Y13,57BB15,71M07. 05A10-CAB DOOR RESTRICTORIS BEEN TAMPERED WITH (REPAIR); 37M07-OVERHEAD A... $1,000 $0 Oct 7, 2016
Jul 15, 2015 38237744P RESOLVE CLASS - 2 67M07,56Y10,58F10.67-PROVIDE EMERGENCY COMMUNICATION (PHONE) IN ELEV. (CAB) TO ANOTHER SOURCE.56-CLEAN BED PLATE & RE... $500 $0 Sep 4, 2015
Dec 12, 2012 38224761Y RESOLVE CLASS - 2 98BB05,02X10. $500 $0 Feb 1, 2013
Mar 5, 2010 38209754K RESOLVE CLASS - 2 16J1.03M11.15M7.69M7 16J01 ADJUST 4 FL HOISTWAY DOOR INTERLOCK TO ALLOW CAR STOP WHEN DOOR IS PULLED 03M11 REPLACE HA... $0 $0 Apr 30, 2010
May 23, 2007 32053773J RESOLVE Hazardous 50A/50B/50C/50D/.50A-BACKFLOW PREVENTOR MISSING.50B-LEAKS ON BOILER FEED LINE.50C-BOILER OPERATING OVER 100 PSI REQUI... $0 $0 Jul 20, 2007
Jul 27, 2006 38160635N RESOLVE Non-Hazardous 83X10 83/X REPAIR ELEVATOR SO A FULL INSPECTION CAN BE MADE. $0 $0 Sep 15, 2006
Jul 15, 2005 34482690M RESOLVE Hazardous FAILURE TO MAINTAIN: DEFECTIVE RETAINING WALL AT SIDE ADJACENT TO 3016BAILEY AVE. HAS COLLAPSE WITH DEBRIS THROUGHOUT... $2,000 $0 Sep 23, 2005
Mar 3, 2005 34468664H RESOLVE Hazardous FAILURE TO MAINTAIN:DEFECTNOTED-RETAINING WALL AT SIDE ADJACENT TO 3016 BAILY AVE HAS COLLAPSED WITH DEBRIS THROUGHOU... $800 $0 Jun 3, 2005
Aug 21, 2004 38148659X RESOLVE Hazardous 41L7,57H11,36B10. 41-SELECTOR MICRO SWITCHES DAMAGE DEFECTIVE PROVIDE NEW 57-TRUST PLAY REPLACE THRUST BEARINGS 36-OV... $500 $0 Oct 1, 2004
Aug 6, 2002 32034116X RESOLVE Non-Hazardous 16/36/ BQ9 27-147 NATCO BOILER MODEL VWG 400CH 12C BNCX SERIAL DO2CA 0054 NB#198934 HOT WATER BOILER INSTALLED INSTAL... $500 -$500 Sep 20, 2002
Aug 6, 2002 32034115Y RESOLVE Non-Hazardous 49/MUST REPLACE MISSING COVER ON PRESSURE TROL MUST INSTALL A DISCHARGE PIPE FROM SAFTY VALVE TO FLOOR TO PREVENT SCA... $0 $0 Sep 20, 2002
Mar 24, 1998 38071984R RESOLVE Non-Hazardous 14M7,17R12,28H12,53X11,11X11,26Q3,3O2,30O2,25H12,3B12,57O2,62K11,15B1.53-OVERHEAD. 25-REPLACE BELT. 3-REPLACE SADDLE. $0 $0 May 8, 1998