ECB violations

3840 Orloff Avenue, Bronx • Block 03263 • Lot 0172

34 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Mar 23, 2026 39181456R ACTIVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE COFO OR DEPARTMENT RECORDS. AT TIME OF INSPECTION, WITHIN THE STORAGE SPACE... $2,500 $2,500 May 29, 2026
Sep 26, 2025 35718498R ACTIVE CLASS - 1 FAILURE TO MAINTAIN EXTERIOR EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTED: OBSERVED AT EXP 1(W. ELEV) CRACKED BR... $25,000 $25,000 Dec 5, 2025
May 19, 2025 39148364P ACTIVE CLASS - 1 RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE, AS PER 1RCNY 11-02.... $6,250 $6,250 Aug 1, 2025
Feb 20, 2025 35689980P ACTIVE CLASS - 1 FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION I OBSERVED-EXP #1 WEST(ORLOFF... $25,000 $25,000 May 2, 2025
Jun 3, 2023 39087690Y ACTIVE CLASS - 1 RESPONDING TO 311 COMPLAINT ON A ELEVATOR, UPON INSPECTION OF DEVICE CEASE USE VIOLATION WAS ISSUED FOR DLM NOT WORKI... $12,500 $12,500 Aug 18, 2023
Mar 10, 2023 39081224J RESOLVE CLASS - 1 CLASS 1: DOOR LOCK MONITORING INOPERATIVE. REPAIR IMMEDIATELY & TEST. $1,250 $1,250 May 19, 2023
Jan 23, 2023 38274728H ACTIVE CLASS - 1 97X17:97-X-17=ENTIRE DEVICE INOPERATIVE. UPON INSPECTION THE DEVICE MENTION ABOVE IS FOUND TO BE OUT OF SERVICE THIS ... $6,250 $6,250 Mar 31, 2023
Dec 14, 2022 39075653R ACTIVE CLASS - 1 CEASE USE VIOLATION WAS ISSUED, RESPONDING TO ELEVATOR 311 COMPLAINT UPON INSPECTION OF DEVICE THE FOLLOWING ITEMS WA... $6,250 $6,250 Feb 17, 2023
Oct 18, 2022 39072217R ACTIVE CLASS - 1 CONTRARY TO DOB/OFFICIAL RECORDS: AT TIME OF INSPECTION BUILDING STORAGE SPACE LOCATED WEST AT NORTH SECTION/FRONT OF... $12,500 $12,500 Dec 2, 2022
Aug 10, 2022 39067746X ACTIVE CLASS - 1 CEASE USE BEST BOILER MODEL #4B90 DUE TO HAZARDOUS CONDITION, SMOKE ALARM NOT OPERABLE DURING AN INCIDENT HEAVY SMOKE... $6,250 $6,250 Sep 30, 2022
Aug 10, 2022 39067747H ACTIVE CLASS - 2 FOUND SMOKE ALARM NOT OPERABLE AND BYPASSED, CHIMNEY BASE NOT PROPERLY SEALED, EXPOSED WIRING, OIL PUMP SET RUNNING C... $3,125 $3,125 Sep 30, 2022
Feb 23, 2022 38274340L ACTIVE CLASS - 1 42X10,42M07:42-X-10 REPAIR INOPERATING DLM SYSTEM 42-M-07 DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMAN'S SERVI... $6,250 $6,250 May 20, 2022
Nov 15, 2021 39051137Y ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. I OBSERVED AND SMELT DIRTY SEWAGE WATER SEEPING OUT FROM UNDER... $3,125 $3,125 Jan 7, 2022
Jun 9, 2021 39042510Z ACTIVE CLASS - 2 PROVIDE FIRE SERVICE AS PER 2.27.3.3.6 OF APPENDIX K OF THE 2014 NYCBC. REMEDY; FILE APPLICATION, INSTALL FIRE SERVIC... $3,125 $3,125 Sep 3, 2021
Jan 15, 2021 39034947L RESOLVE CLASS - 2 MUST PROVIDE FIRE SERVICE ON THIS DEVICE AS PER 2.27.3.3.6 OF APPENDIX K OF THE NYCBC. $1,563 $1,563 Mar 5, 2021
Oct 8, 2020 39030064J ACTIVE CLASS - 2 BECAUSE OF THE FILING COST OF DLM PERMIT NUMBER X00361500-I1-VT, FIRE SERVICE MUST BE PROVIDED TO COMPLY WITH 2.27.3.... $3,125 $3,125 Dec 4, 2020
Jun 6, 2020 38273556X RESOLVE CLASS - 1 42M07;52-M-07 NO DOOR LOCK MONITORING INSTALLED IN CONTROLLER AS MANDATED BY 3-10-12 OF APPENDIX K3 OF 2014 NYC BUILD... $1,250 $1,250 Jan 22, 2021
Jun 2, 2020 39023295L RESOLVE CLASS - 1 CEASE USE BEST BOILER MODEL #4B90- DO NOT OPERATE BOILER TIL ALL HAZARDOUS CONDITION ARE CORRECTED AND DOB IS NOTIFIE... $0 $0 Jan 22, 2021
Mar 9, 2020 39019211N ACTIVE CLASS - 2 FOUND DISCHARGE PIPE AND BODY DRAIN MISSING ON SAFETY RELIEF VALVE, BELT GUARD MISSING AT PUMP SET, CONDENSATE TANK N... $625 $0 Oct 9, 2020
Aug 22, 2018 38264736Z ACTIVE CLASS - 2 67-X-10,64-M-07,05-J-10,12-Q-07,41-M-07,45-M-13,59-BB-05,70-O-02,80-M-07.(67-X-10)=REMEDY REPAIR IN CAR PHONE.(64-M-0... $3,125 -$2,067 Oct 19, 2018
Jun 24, 2018 38263939Y RESOLVE CLASS - 2 97X10:UPON INSPECTION OF ELEVATOR IT WAS FOUND THAT THE ELEVATOR IS NOT WORKING.REM:RESTORE AND REPAIR TO SERVICE. $1,562 -$1,562 Aug 17, 2018
Oct 17, 2016 38250009P RESOLVE CLASS - 1 97X10/DOB RECORDS SHOW THE ONLY ELEVATOR IN BLDG AS ACTIVE.UPON INSPECTION,THE DEVICE IS FOUND TO BE OUT OF SERVICE C... $2,500 -$2,500 Dec 2, 2016
Apr 19, 2013 38226498P RESOLVE CLASS - 2 68M07,44H10,52*10,56Y10,99BB05,73O02,74O02,59Y02,97L10,21Q03,64A11,67M07,70O02,72M10,71X10,39O02. 68-AS PER ASME A17.... $2,500 $0 Jun 7, 2013
Nov 23, 2012 38223898K RESOLVE CLASS - 2 17H10,70O02,72M10,08V10,52K10,44H08,73O02,74O02,56Y13,68B07. 17- ALL FLRS, 1-6. 72- PROVIDE AS PER APPENDIX K. 08- RE... $2,500 $0 Jan 18, 2013
Dec 15, 2010 38214481K RESOLVE CLASS - 2 05H10 05H10 70O02 72M10 56Y13 42H10 17H10 44H08 98BB05 99H05 16M10. 05- CAR DOOR GIBS. 05- CAR DOOR ROLLERS. 42H10- R... $500 $0 Apr 15, 2011
Nov 18, 2005 38155681H RESOLVE Non-Hazardous 41G11/57I10/34Q3/21Q3/12X11/17H11/84H11/38O2/32O2/35O2/67O2/68O2/69O2/71O2. 57 BRASS SHEAVING IN GEAR OIL. 34-COVER W... $2,500 $0 Jan 6, 2006
Mar 11, 2005 38151489J RESOLVE Non-Hazardous 10H10/17H10/41G11/40D06/85U05/21Q03/67O02/68O02.01D06. 41G11-FUSE WIRE JUMPED. 21Q03-2ND FL. $350 $0 Oct 7, 2005
May 13, 2004 34424164R ACTIVE Non-Hazardous FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED/LAUNDRY ROOM WITH 2 OR MORE DRYERS REQUIRE SPRINKL... $2,500 $0 Jul 2, 2004
May 13, 2004 34424165Z RESOLVE Non-Hazardous PIPING AND /OR EQUIP. INSTALLED IMPROPERLY/DRYERS ARE INSTALLED WITH STOVE FLEX CONNECTORS.REMEDY: INSTALL PIPING AND... $700 $0 Oct 11, 2005
Aug 31, 2000 34261177M ACTIVE Non-Hazardous FAILURE TO FILE A REPORT OF COMPLIANCE WIGH LOCAL-LAW 16/84 CERTIFYINGTO THE INSTALLATION OF REQUIRED FIRE PROTECTION... $400 $0 Jun 1, 2001
Aug 31, 2000 34261183Z RESOLVE Non-Hazardous FAILURE TO PROVIDE 3" FLOOR NUMBER SIGNS AT STAIR LANDING ON ALL FLOORS FAILURE TO PROVIDE 3" STAIR AND ELEVATOR SIGN... $800 $0 Jun 1, 2001
Feb 3, 2000 38093657R RESOLVE Non-Hazardous 11Q3,28H12,35P17,57O2. 11- CAR LIGHT UNGRARDED. 28-GUIDES WORNED. 35- NO ACCESS TO MOTOR ROOM. 57- PIT DIRTY. $0 $0 Mar 24, 2000
Oct 21, 1992 38027510R RESOLVE Non-Hazardous 3M,14I,30O,35P,#3CAPACITY PLATE#30CLEAN RAILS #35SUPER HAS NO KEY. $5,000 $0 Dec 18, 1992
Feb 5, 1992 38021614Y RESOLVE Non-Hazardous 35P,14I,03M,30O, PROVIDE ACCESS TO MOTOROOM SO A COMPLETE INSP. CAN BEMADE (NO KEYS ON PREMISES). (03) PROVIDE CAPACI... $1,000 $0 Mar 20, 1992