ECB violations
East 191 Street, Bronx • Block 03273 • Lot 0001
148 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 6, 2011 | 34911129J | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS AT TIME OF INSPECTION & WHILE DEMO WO... | $1,200 | $0 | Jul 29, 2011 |
| May 23, 2011 | 34910735P | RESOLVE | CLASS - 1 | AT TIME OF INSP OBSERVED MALE WORKERS ON SCAFFOLD OVER 10'IN HEIGHT 2 WORKERS HAD AN USER CARD REM; DISCONTINUE ACTIV... | $1,600 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910740J | RESOLVE | CLASS - 2 | AT TIME OF INSP OBSERVE AT SEVERAL FLOOR LVL FIRE EXTINGUISHERS THAT HAVE BEEN DISCHARGED MAKING THAN NON FUNCTIONAL ... | $1,200 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910732J | RESOLVE | CLASS - 2 | AT TIME OF INSP OBSERVED NO PERMITS POSTED TO FENCE AT ANY EXPOSURE REM: POST PERMIT | $0 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910738K | RESOLVE | CLASS - 2 | 27-1032B BC3304.4.4 FAILURE TO PROVIDE 3FT 6"INCH GUARDRAIL OR SOLID ENCLOSURE AROUND OPEN & ACCESSIBLE SIDE OF EXCAV... | $0 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910739M | RESOLVE | CLASS - 2 | 27-1031 BC3304.2 FAILURE TO ADEQUATELY SUPPORT ADJOINING GROUND AND/ORSTRUCTURE AFFECTED BY EXCAVATED AT TIME OF INSP... | $0 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910736R | RESOLVE | CLASS - 2 | AT TIME OF INSP OBSERVE AT BSMT LVL GASOLINE CONTAINERS NOT STORED PROPERLY REM: REMOVE CONTAINERS PROTECTED PERSON &... | $1,200 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910733L | RESOLVE | CLASS - 3 | 27-132 BC1704.1.1 FAILURE TO FILE A SPECIAL INSP STATMEN OF RESPSIBILITY PRIOR TO PERMIT ISSUANCE AND PRIOR TO START ... | $0 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910728R | RESOLVE | CLASS - 2 | AT TIME OF INSP OBSERVED AT BSMT LVL UNDERPINNING BEING PERFORMED NOT IN ACCORDANCE W/ APPROVAL PLANS AT SITE NOTE PU... | $0 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910729Z | RESOLVE | CLASS - 2 | RCNY27-04 BC3301.9.1 FAILURE TO PROVIDE A SIGN W/ THE WORKING TO ANONYMOUSLY REPORT UNSAFE CONDITIONS AT THIS WORK SI... | $0 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910730X | RESOLVE | CLASS - 2 | AT TIME OF INSP OBSERVE NO CONTRACTOR SIGN POSTED AT ANY FRONTAGE REM;PROVIDE CONTRACTOR SIGN | $0 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910731H | RESOLVE | CLASS - 2 | AT TIME OF INSP OBSERVED NO NO SMOKING SIGNS POSTED TO EXTERIOR OF FENCE & NAIL TO EACH FLOOR REM: COMPLY W/ CODE | $0 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910734N | RESOLVE | CLASS - 2 | 27-1009A BC3314.8 FAILURE TO PROVIDE REQUIRED GUARD RAIL & TOE BOARD FOR SCAFFOLD PLATFORM AT TIME OF INSP OBSERVED S... | $0 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910737Z | RESOLVE | CLASS - 2 | 27-1009A BC3301.2 FAILURE TO PROVIDE 3'FT 6"INCH GUARDRAIL OR EQUIVALENT AROUND ALL FLOOR AND PERIMETER FLOOR OPENING... | $0 | $0 | Jul 15, 2011 |
| May 23, 2011 | 34910742N | RESOLVE | CLASS - 3 | 27-1024B BC3307.5.2 FAILURE TO PROVIDE REQUIRES FLAGMAN WHEN INTERMITTENS OPERATION ON OR ACROSS AREAS OPEN TO PUBLIC... | $0 | $0 | Jul 15, 2011 |
| Oct 29, 2010 | 34885533P | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS FOR ALT 2 JOB#220027986 OF WHICH PERMIT IS ACTIVE AND APPL O... | $0 | $0 | Jan 7, 2011 |
| Jan 27, 2010 | 36012514J | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ARCHITECT / ENGINEER REPORT CERTIFYING EXIT / DIRECETIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER ... | $4,000 | $0 | Aug 6, 2010 |
| Jan 27, 2010 | 36012513H | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ARCHITECT / ENGINEER REPORT CERTIFYING EXIT / DIRECETIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER ... | $4,000 | $0 | Aug 6, 2010 |
| Jan 27, 2010 | 36012515L | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ARCHITECT / ENGINEER REPORT CERTIFYING EXIT / DIRECETIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER ... | $2,000 | -$2,000 | Aug 6, 2010 |
| Nov 27, 2009 | 36010640L | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXT... | $4,000 | $0 | Oct 15, 2010 |
| Nov 17, 2009 | 34786500P | RESOLVE | CLASS - 1 | SEC. 1905.6.3.2. FAILURE TO LABORATORY CURE STRENGTH CYLINDERS IN ACCORDANCE W/ASTMC-31. NOTED: AT THE TIME OF INSPEC... | $1,600 | $0 | Feb 5, 2010 |
| Nov 17, 2009 | 38207634R | RESOLVE | CLASS - 2 | 97X10.REPAIR AND RETURN TO SERVICE SO THAT A FULL INSPECTION CAN BE MADE BY THIS DEPT | $500 | $0 | Apr 9, 2010 |
| Nov 17, 2009 | 34786502Z | RESOLVE | CLASS - 1 | SEC. 1905.6.3.2. FAILURE TO LAB CURE STRENGTH CYLINDERS IN ACCORDANCE W/ASTMC-31. NOTED: AT THE TIME OF INSPECTION AT... | $0 | $0 | Feb 5, 2010 |
| Mar 6, 2009 | 38202001Y | RESOLVE | CLASS - 2 | 12Q03.70O021.70Z02. | $500 | $0 | May 1, 2009 |
| Jan 30, 2009 | 36008303H | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLAINCE WITH CODE PROVISIONS: PERIODIC INSPECTION ... | $0 | $0 | Jan 20, 2010 |
| Nov 13, 2008 | 34701930J | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: AT TIME OF INSPECTION, WORK O... | $2,400 | $0 | Jan 16, 2009 |
| Oct 2, 2008 | 34701737H | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPS. RESPONDENT HAS ERECTED A PIPE SCAFFOLD AT ... | $0 | $0 | Nov 30, 2009 |
| Oct 2, 2008 | 34701738J | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPS. "NO SMOKING" SIGNS WITHIN CONST. SITE NOT ... | $0 | $0 | Nov 30, 2009 |
| Dec 4, 2007 | 38180356Z | RESOLVE | Non-Hazardous | 36T07,36Q03,59Q03,86BB05.36T07-PROVIDE SIGN FOR OVERHEAD SHEAVE ROOM DOOR.36Q03-INSTALL GUARD FOR LIGHT IN OVERHEAD S... | $350 | $0 | Feb 1, 2008 |
| Apr 10, 2006 | 38157772M | RESOLVE | Non-Hazardous | 84M11/12M07. #84- REPLACE HANDRAILING ELEVATOR | $350 | $0 | Aug 25, 2006 |
| Oct 5, 2005 | 34499001Z | RESOLVE | Non-Hazardous | NEW BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY. NEW BUILDING NUMBER 200876374. REMEDY: DISCONTINUE IL... | $0 | $0 | Dec 2, 2005 |
| Aug 12, 2005 | 34478299H | RESOLVE | Hazardous | OCCUPANCY CONTRARY TO THE BUILDING DEPT RECORDS. RECORDS SHOW VACANT PAVED LOT LEGAL AT REAR OF SAID ADDRESS. ILLEGAL... | $0 | $0 | Sep 23, 2005 |
| Feb 8, 2005 | 38150723Y | RESOLVE | Non-Hazardous | 86BB05/47Y13/84Y13/66Y09/09H11. 86-2 YEAR PRESSURE RELIEF TEST. 84 PISTON PACKING LEAKING OIL. | $180 | $0 | Mar 25, 2005 |
| Apr 14, 2004 | 38146538K | RESOLVE | Non-Hazardous | 83X10/66Z10 83- REPAIR AND RESTORE TO SERVICE FOR A COMPLETE INSPECTION B4 THIS DEPT. | $350 | $0 | May 28, 2004 |
| Apr 14, 2004 | 38146540J | RESOLVE | Non-Hazardous | 10H10/21Q03/17H10/47Y10/66Z10/24X10/66Y10/15I10. 21- 2ND AND 4TH FLOORS 17- BASEMENT 66Y10-PISTON SEAL | $350 | $0 | May 28, 2004 |
| Aug 28, 2003 | 34402514K | RESOLVE | Hazardous | FAILURE TO MAINTAIN:DEFECT IS FORDHAM UNIVERSITY CHURCH ON CAMPUS METAL STAIRWAY TO CHURCH BASEMENT COLLAPSED INTO ST... | $2,500 | $0 | Oct 17, 2003 |
| Jun 4, 2003 | 38139550H | RESOLVE | Non-Hazardous | 47Y10 | $350 | $0 | Aug 1, 2003 |
| Jun 4, 2003 | 38139551J | RESOLVE | Non-Hazardous | 47Y10,38X10,05E10. 38-TOP OF CAR LIGHTS | $350 | $0 | Aug 1, 2003 |
| Jun 4, 2003 | 38139099M | RESOLVE | Non-Hazardous | 20I11,34Q03. 20-BASEMENT DOOR 34-MOTOR LEADS | $350 | $0 | Jul 25, 2003 |
| Jun 4, 2003 | 38139552L | RESOLVE | Non-Hazardous | 05E10 | $350 | $0 | Jul 25, 2003 |
| May 21, 2003 | 38138979X | RESOLVE | Non-Hazardous | 25W6 24X10 | $2,500 | $0 | Jul 18, 2003 |
| May 21, 2003 | 38138976K | RESOLVE | Non-Hazardous | 1X10 1-ALARM PART | $2,500 | $0 | Jul 18, 2003 |
| May 21, 2003 | 38138978Y | RESOLVE | Non-Hazardous | 21Q3 66O2 14M11 3X10 3-OUTSIDE COMMUNICATION SYSTEM | $2,500 | $0 | Jul 18, 2003 |
| May 21, 2003 | 38138977M | RESOLVE | Non-Hazardous | 37R09 MAINENANCE BYPASS SWITCH ON CONTROLLER FOR FRONT AND REAR DOORS | $2,500 | $0 | Jul 18, 2003 |
| May 14, 2002 | 38122913R | RESOLVE | Non-Hazardous | 57ZC/ 73X11/ (57) WATER AND DIRTY IN PIT (730 NOT WORKING AT TIME OFINSPECTION RESTORE DEVICE HAVE A FULL INSPECTION ... | $2,500 | $0 | Nov 22, 2002 |
| Jun 12, 2000 | 34238807M | RESOLVE | Non-Hazardous | NEW BUILDING OCCUPIED WITHOUT A VALID C OF O NUMBER 200533100. REMEDY: OBTAIN A VALID C OF O. | $0 | $0 | May 17, 2002 |
| Mar 17, 2000 | 34206275Y | RESOLVE | Hazardous | FAILURE TO PROVIDE TOP RAIL,MID RAIL ON SCAFFODING DURING CONSTRUCTIONOPERATION.NOTE:AT NORTH ELEVATION OF EAST WING ... | $500 | $0 | Jun 15, 2000 |
| Mar 10, 2000 | 34219906Y | RESOLVE | Non-Hazardous | WORK W/O A PERMIT.WORK NOTED:INSTALL A MORGEN SCAFFOLDING.FIVE STORIES SCAFFOLD.LOCATION NO./WEST/SO. SIDE OF NEW BLD... | $0 | $0 | Apr 28, 2000 |
| Oct 25, 1999 | 38091067H | RESOLVE | Non-Hazardous | 12X11,12I11,57O2,57Z2,28H12,55X12,30O2,30A4,34M7,74X11. 30-PATCH HOLE IN SHAFTWAY ON BMENT LEVEL. 34-JUNCTION BOX COV... | $0 | $0 | Jun 30, 2000 |
| Oct 12, 1999 | 38090999N | RESOLVE | Non-Hazardous | 75U5,57Z9. | $0 | $0 | Nov 26, 1999 |