ECB violations
355-359 East 194 Street, Bronx • Block 03282 • Lot 0065
13 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 17, 2024 | 39103661M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN. AT 3RD FLOOR STAIRCASE THE OUTSIDE WINDOW PANE IS BROKEN WITH ENTIRE WINDOW IN DISREPAIR., REPAI... | $0 | $0 | Mar 29, 2024 |
| Aug 4, 2023 | 38274858X | RESOLVE | CLASS - 1 | 59-BB-5,99-BB-5. 59-BB-5=BRAKE MAINTENANCE EXPIRED SINCE 2021, MUST PERFORM BRAKE MAINTANENCE IMMEDIATELY AND PROVIDE... | $1,250 | $0 | Oct 20, 2023 |
| May 4, 2023 | 39085478H | RESOLVE | CLASS - 1 | RESTORE TO SERVICE; ELEVATOR OUT OF SERVICE | $3,125 | -$9,375 | Feb 6, 2024 |
| Apr 3, 2023 | 39082876J | RESOLVE | CLASS - 1 | RESPONDING TO A 311 ELEVATOR COMPLAINT,UPON INSPECTION OF DEVICE IT WAS FOUND TO BE OUT -OF - SERVICE, REMEDY; RESTOR... | $6,250 | -$6,250 | Jun 16, 2023 |
| Mar 12, 2023 | 39081270K | RESOLVE | CLASS - 1 | ELEVATOR CURRENTLY STUCK IN BASEMENT AND OUT OF SERVICE, NOT TAKING CALLS; REPAIR AND RESTORE TO SERVICE | $6,250 | -$4,873 | Jun 16, 2023 |
| Feb 6, 2023 | 38274736H | RESOLVE | CLASS - 1 | 97X17,59BB5:97-X-17=ENTIRE DEVICE INOPERATIVE. UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE ON A 6 STORY ... | $1,250 | $0 | Apr 21, 2023 |
| Dec 12, 2018 | 38267011P | RESOLVE | CLASS - 2 | 68B01,39I10,39O02,70O02. 68B01-RMDY ADJUST MAINTENANCE LOGIN. 39I10- RMDY REPAIR CAR TOP LIGHT; 39O02-RMDY CLEAN CAR ... | $313 | $0 | Mar 15, 2019 |
| Dec 29, 2009 | 34814448M | RESOLVE | CLASS - 2 | INADEQUATE DETAILS ON APPROVED PLANS FOR ELEVATIONS DEFINING DEPTH OF REQUIRED EXCAVATION FOR FOOTINGS/FOUNDATIONS NO... | $2,500 | $0 | Feb 19, 2010 |
| Dec 14, 2009 | 34814309M | RESOLVE | CLASS - 2 | FAIL TO PROVIDE PROTECTION @ SIDES OF EXCAVATION NOTED @ TIME OF INSPCONTRACTOR CUT SHEAR CUT @ EXP 2 APPROX 12FT DEE... | $2,500 | $0 | Feb 5, 2010 |
| Dec 14, 2009 | 34814310J | RESOLVE | CLASS - 1 | BC3304.7(MISC)FAIL TO PROVIDE ADEQUATE MEANS OF EXIST FROM EXCAVATION NOTED@ TIME OF INSP CONTRACTOR FAILED TO PROVID... | $8,000 | $0 | Feb 5, 2010 |
| Dec 14, 2009 | 34814311L | RESOLVE | CLASS - 2 | BC3309.6(MISC)FAIL TO MONITOR ADJOINING STRUCTURES FOR MOVEMENT IN ALLDIRECTIONS DURING EXCAVATION RELATED ACTIVITY T... | $400 | $0 | Feb 5, 2010 |
| Sep 14, 2009 | 34787301R | RESOLVE | CLASS - 3 | WORK W/O A PERMIT. WORK NOTED: 8 FEET PLYWOOD CONSTRUCTION FENCE AROUND PREMISES. REMEDY: OBTAIN PERMIT. | $100 | $0 | Nov 6, 2009 |
| May 7, 2007 | 34576467R | RESOLVE | Non-Hazardous | NO DOT PERMIT POSTED.UPON INSP AT 335 EAST 94 ST DEMO CREW LOADING CONTAINER W/ MACHINE,THE CONTAINER IS ON THE TRUCK... | $5,000 | $0 | Jul 6, 2007 |