| Mar 22, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY-OPERATED LOCK ON THE DOOR LEADING TO THE FIRE E... | 7D | Apr 26, 2022 |
| Mar 22, 2022 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 7D, 6th ... | 7D | Apr 17, 2022 |
| Mar 22, 2022 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 7D, 6th STO... | 7D | Apr 26, 2022 |
| Mar 22, 2022 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 7D, 6th STO... | 7D | Apr 17, 2022 |
| Mar 22, 2022 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ADJUST THE H... | 7D | Apr 17, 2022 |
| Mar 22, 2022 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND WEST WALL IN... | 7D | Jun 25, 2022 |
| Mar 22, 2022 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFFECTIVE IN THE ENTIRE APARTMENT LOCATE... | 7D | Apr 26, 2022 |
| Mar 22, 2022 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FRO... | 1E | Mar 28, 2022 |
| Mar 7, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF OBSTRUCTION AT WINDOW FRAME PREVENTING WINDOW FROM ... | 1A | Apr 11, 2022 |
| Mar 7, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE FIRE RATED DOOR IN THE ENTRANCE LOCATED AT APT 1A, 1st STO... | 1A | Apr 11, 2022 |
| Mar 7, 2022 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | 1A | Jun 10, 2022 |
| Mar 7, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT 1A, 1s... | 1A | Mar 13, 2022 |
| Feb 17, 2022 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | May 23, 2022 |
| Feb 8, 2022 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL IN THE FOYER ... | 4G | May 14, 2022 |
| Feb 8, 2022 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW FRAME FROM WE... | 4G | May 14, 2022 |
| Feb 8, 2022 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL IN THE FOYER ... | 4G | May 14, 2022 |
| Jan 20, 2022 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1... | — | Apr 25, 2022 |
| Jan 20, 2022 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFFECTIVE IN THE ENTIRE APARTMENT LOCATE... | 1A | Feb 24, 2022 |
| Jan 20, 2022 | C | VIOLATION CLOSED | § 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS AT APT IN THE ENTRANCE LOCATED AT APT 1A, 1s... | 1A | Feb 15, 2022 |
| Jan 20, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... | — | Feb 24, 2022 |
| Jan 20, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH IN THE ENTIRE APARTM... | 1A | Feb 24, 2022 |
| Jan 20, 2022 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STOR... | 1A | Feb 24, 2022 |
| Jan 7, 2022 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 4G | Feb 11, 2022 |
| Jan 7, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE B... | 4G | Jan 13, 2022 |
| Jan 7, 2022 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX (10 SQ FT.) NORTH WALL IN... | 4G | Feb 11, 2022 |
| Jan 7, 2022 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX (10 SQ FT.) EAST WALL IN ... | 4G | Feb 11, 2022 |
| Jan 7, 2022 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCA... | 4G | Feb 11, 2022 |
| Jan 7, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL, CEIL... | 4G | Feb 11, 2022 |
| Jan 7, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE... | 4G | Feb 11, 2022 |
| Jan 7, 2022 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FRO... | 4G | Feb 11, 2022 |
| Jan 7, 2022 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 4G | Feb 2, 2022 |
| Jan 7, 2022 | B | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX (10 SQ FT.) SOUTH WALL IN... | 4G | Feb 11, 2022 |
| Jan 7, 2022 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3... | 4G | Feb 11, 2022 |
| Jan 7, 2022 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT ... | 4G | Feb 14, 2022 |
| Jan 6, 2022 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL, NORT... | 4G | Apr 11, 2022 |
| Jan 6, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 4G | Jan 12, 2022 |
| Jan 6, 2022 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 4G | Apr 11, 2022 |
| Jan 6, 2022 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT ... | 4G | Feb 13, 2022 |
| Jan 6, 2022 | C | VIOLATION CLOSED | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT ... | 4G | Feb 13, 2022 |
| Jan 6, 2022 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE AT THE CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED ... | 4G | Apr 11, 2022 |
| Jan 6, 2022 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 2 SQUARE FEET AT THE CEILING AND... | 4G | Apr 11, 2022 |
| Jan 6, 2022 | C | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 10 SQUARE FEET AT EAST WALL, 10 ... | 4G | Feb 1, 2022 |
| Jan 6, 2022 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 4G | Jan 12, 2022 |
| Jan 6, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... | 4G | Jan 12, 2022 |
| Jan 6, 2022 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 4G | Apr 11, 2022 |
| Jan 6, 2022 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES I... | 4G | Apr 11, 2022 |
| Jan 4, 2022 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING APPROX. ... | 5A | Jan 10, 2022 |
| Jan 4, 2022 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX. 5 SQ.FT. IN T... | 5A | Apr 9, 2022 |
| Jan 4, 2022 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT SOUTH WALL IN THE KITCHEN LOCATED AT ... | 5A | Feb 8, 2022 |
| Jan 4, 2022 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE IN THE BATHROOM LOCATED AT APT... | 5A | Feb 8, 2022 |