| Sep 12, 2025 | 39160248J | ACTIVE | CLASS - 1 | CLASS 1 ITEMS: 1) NO DOOR LOCK MONITORING INSTALLED ON THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2... | $3,125 | $3,125 | Nov 21, 2025 |
| Oct 25, 2024 | 39128503H | ACTIVE | CLASS - 1 | RESPONDING, TO A 311 ELEVATOR COMPLAINT. UPON INSPECTION, CEASE USE VIOLATION ISSUED FOR, CAR STOP IN 2FEET LOWER THA... | $1,250 | $1,250 | Jan 3, 2025 |
| May 3, 2024 | 39113457Y | RESOLVE | CLASS - 1 | RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION OF A SINGLE CAR BUILDING THE DEVICE WAS FOUND TO BE OUT OF SE... | $3,125 | $3,125 | Aug 23, 2024 |
| Dec 8, 2023 | 39100996K | ACTIVE | CLASS - 1 | DOOR LOCK MONITORING NOT INSTALLED AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE NYCBC. THIS SAFETY DEVICE ENSURES PAS... | $1,250 | $1,250 | Mar 15, 2024 |
| Oct 4, 2023 | 39096440X | ACTIVE | CLASS - 1 | ONLY ELEVATOR IN THE BUILDING OUT OF SERVICE SITTING ON THE 6TH FLOOR. RESTORED DEVICE BACK TO SERVICE IMMEDIATELY AN... | $1,250 | $1,250 | Dec 15, 2023 |
| Apr 20, 2023 | 39084248H | ACTIVE | CLASS - 1 | CLASS 1 ITEM: DOOR LOCK MONITORING MISSING, INSTALL. CLASS 2 ITEMS: LIGHT INSIDE THE CAR MISSING A GUARD, PROVIDE. MO... | $1,250 | $1,250 | Jun 30, 2023 |
| Sep 2, 2021 | 39047024X | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED. UPON INSPECTION THE DEVICE IS FOUND TO BE OUT- OF SERVICE CREATING A HAZARDOUS CONDITION PE... | $3,125 | $3,125 | Dec 3, 2021 |
| Jan 4, 2021 | 35542412K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE:AT THE TIME OF THE INSPECTION OBSERVED AT EXPOSU... | $1,250 | $1,250 | Jul 9, 2021 |
| Apr 22, 2019 | 38270765Z | RESOLVE | CLASS - 2 | 37X10,100B01,58H10,71X10,70O02,46M07,56Y10,64M07. 27X-REPAIR LIGHT INOVERHEAD MOTOR ROOM; 100B-ADJUST GAP BETWEEN CAR... | $0 | $0 | Sep 6, 2019 |
| Mar 5, 2019 | 38268422Y | RESOLVE | CLASS - 1 | CU72L10;CU42G10; 08B10,16D10,05J10,64M07,16K10,70O02,42B11,58H10,46M07,56Y10,44Q03,16M07,16N16,05E10,34X10,45H10. 2 C... | $3,125 | $3,125 | Apr 19, 2019 |
| May 18, 2018 | 37010595H | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... | $1,250 | $1,250 | Jan 25, 2019 |
| Apr 11, 2018 | 38262604H | RESOLVE | CLASS - 2 | 08B01,67X10,100B07. 08B01- CAR FLOOR TO LANDING SILL IS 2 1/4 INCHES WIDE. RMDY: ADJUST TO CODE; 67X10-CAR PHONE NOT ... | $0 | $0 | Jun 1, 2018 |
| Feb 27, 2018 | 38260631Y | RESOLVE | CLASS - 2 | 67X10;54M07;70O2;71X10;40P07;32H11;16T07:PROVIDE MISSING NUT ON COUNTERWEIGHT;PROVIDE ACCESS TO MOTOR ROOM;GUIDE SHOE... | $0 | $0 | Apr 20, 2018 |
| Oct 3, 2016 | 35180094Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. NOTE IN APART(BMI)AT THE BASEMENT LEVEL A SECTION CONCRETEW FLOO... | $250 | $0 | Dec 30, 2016 |
| Apr 12, 2010 | 38210217N | RESOLVE | CLASS - 2 | 15M07/ 16L11/ 35Q03/ 37Q03/ 37X10/ 39O02/ 43Q03/ 56Y13/ 59Q03/ 60Q03/ 68M07/ 69M07/ 77M07/ 16-L-11 REPLACE DEFECTIVE ... | $500 | $0 | Jun 4, 2010 |
| Oct 5, 2009 | 38206613N | RESOLVE | CLASS - 2 | 16L10.21L10.100M10.98M7 16-21-L-10 2ND FK INTERLOCK IS LOOSE AND 2ND FL HOISTWAY DOOR HAS EXCESSIVE PLAY WHEN PULLED ... | $0 | $0 | Dec 4, 2009 |
| Sep 21, 2009 | 34744364Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG WALLS & APPURTENANCES.(I)DEFECTIVE JOINTS WERE FOUND(MISSING OF MORTAR)AT DECORATIV... | $0 | $0 | Apr 16, 2010 |
| Aug 4, 2009 | 38205425L | RESOLVE | CLASS - 2 | 15M7.33M7 16L10 REPAIR 5TH FKL HOISTWAY SOOR AND RETURN TO FL BACK TO SERVICE 37T7 PROVIDE SIGN FOR OVERHEAD SHEAVE R... | $0 | $0 | Oct 2, 2009 |
| Jul 14, 2008 | 38189316P | RESOLVE | CLASS - 3 | 12Q03, 20I11, 21D06, 43Q03, 37T07, 56Y13, 60Q03, 77M11 20-I-11 REPLACE DAMAGE VISION GLASS FOR 1ST & 2ND FL HOISTWAY ... | $0 | $0 | Sep 5, 2008 |
| Sep 19, 2007 | 38168960N | RESOLVE | Non-Hazardous | 12Q3,15B11,31H11,85BB5,86BB5,20M7,11N6,16N6,16B11,32O2,33O2,35O2,38O2,39P7,36P7,66O2,67O2,68O2,69O2,71O2. 12 INSIDE C... | $350 | $0 | Aug 1, 2008 |
| Sep 13, 2007 | 38169524L | RESOLVE | Non-Hazardous | 12Q03,15I11,16X10,16D06,20M11,36T11,51H11,55Y13,71M11,83O02,85BB05,86BB05.16X10-REPAIR 6FL HOISTWAY DOOR & RETURN TO ... | $350 | $0 | Aug 1, 2008 |
| Aug 11, 2006 | 34550492N | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A 5TH ROUND TECHNICAL REPORT IN COMPLIANCE W/ CODE PROVISIONS: PERIODIC INSP OF EXTERIOR WALLS & AP... | $10,000 | $0 | Oct 20, 2006 |
| May 19, 2006 | 34549366Y | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS: PERIODIC INSP. OF EXT. WALLS & APPU... | $10,000 | $0 | Jul 21, 2006 |
| Jan 20, 2006 | 34549030K | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR ... | $10,000 | $0 | Sep 15, 2006 |
| Feb 25, 2005 | 34461296L | RESOLVE | Non-Hazardous | 20050805YDE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED BY LOCAL LAW 11 OF 1998 AN... | $10,000 | $0 | Sep 15, 2006 |
| Aug 6, 2004 | 34461580Z | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED BY LOCAL... | $10,000 | $0 | Nov 5, 2004 |
| Dec 19, 2003 | 34462549P | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OR EXTERIOR WALLS AND APPURTENANCES AS REQUIRED ... | $700 | $0 | Sep 3, 2004 |
| Jan 15, 2000 | 38093879M | RESOLVE | Non-Hazardous | 01L11,02L11,33L11,15I11,30Q03. ALARM SYSTEM, LIGHTS IN OVERHEAD. 2 AND6 FLOORS NOT SELF CLOSING DOOR OLD AND DAMAGED.... | $2,500 | $0 | Mar 10, 2000 |
| Feb 18, 1999 | 38084792P | RESOLVE | Non-Hazardous | 74I,40H,15H,75U. REPAIR TOE GUARD, GOVERNOR KNOCK VERY LOUD, REPAIR SAME, BASEMENT H/D REPAIR OR REPLACE, GOVERNOR NE... | $0 | $0 | Apr 9, 1999 |
| Apr 17, 1998 | 38073166Y | RESOLVE | Non-Hazardous | 15I11X32M30O33P6D11D35P36P57O 15-1-3 FLOOR DAMAGE REPAIR 11-NO LIGHTS IN CAB 38-DUCT COVER MISSING SHAFTWAY 30-CLEAN ... | $180 | $0 | Jun 12, 1998 |
| May 6, 1994 | 38041074K | RESOLVE | Non-Hazardous | 14I,15L,37G,50Y. (37) PROPERLY FUSE CONTROLLER | $200 | $0 | Jul 22, 1994 |
| Jul 20, 1993 | 38035315L | RESOLVE | Non-Hazardous | 73X. RESTORE ELEV. TO SERVICE. | $200 | $0 | Oct 1, 1993 |
| Oct 30, 1992 | 38028672Y | RESOLVE | Non-Hazardous | 11Q,14M,15L,20M,57O,73L,74#,(15)BASEMENT DOOR(20)BASEMENT PUSHBUTTON(73)ELEV.STOPPING BETWEEN FLOORS(74)FILE FOR PERM... | $200 | $0 | Mar 5, 1993 |
| Jan 29, 1992 | 38021619N | RESOLVE | Non-Hazardous | 73X,RESTORE ELEV TO SERVICE SO AN INSP CAN BE MADE BY AN INSP FORM THIS DEPT. | $150 | $0 | Oct 28, 1993 |
| Jul 8, 1991 | 38013683H | RESOLVE | Non-Hazardous | 73X,73 RESTORE ELEVATOR TO SERVICE SO PROPER INSPECTION CAN BE MADE | $150 | $0 | Oct 28, 1993 |