Issued Violation Status Severity Description Penalty Balance due Hearing
Dec 2, 2025 39168896Y RESOLVE CLASS - 2 OBSERVED IN THE BASEMENT A FUTURE OPEN ENDED GAS LINE AND PEX TUBING USED ON WATER LINES FOR SINK. THROUGHOUT THE BUI... $625 $625 Jun 12, 2026
Feb 10, 2025 39137943X RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... $2,500 $0 Oct 23, 2025
Feb 10, 2025 39137893R RESOLVE CLASS - 1 OBSERVED ONE FEDERAL MODEL FST-60 OIL FIRED STEAM BOILER BOILER. CEASED USE DUE TO HAZARDOUS CONDITION: WATER LEAKING... $1,250 $0 Jun 13, 2025
Feb 10, 2025 39137944H RESOLVE CLASS - 2 CODE), & BC 716.5.9 (2022 CODE) EXIT DOOR NOT SELF-CLOSING. OBSERVED ROOF DOOR NON SELF CLOSING. POTENTIAL FIRE HAZAR... $0 $0 Apr 18, 2025
Aug 8, 2022 39067539N RESOLVE CLASS - 2 I OBSERVED ON ALL FLOORS THE IMPROPER INSTALLATION OF EMERGENCY LIGHTS. THE POWER FOR THE LIGHTS ARE BEING SUPPLIED F... $250 $0 Mar 24, 2023
Aug 8, 2022 39067537J RESOLVE CLASS - 2 EXCESSIVE STORAGE IN THE GAS METER ROOM TILES, A SHOPPING CART, PLASTER OF PARIS COMPOUND AND STUDS. NO STORAGE SHALL... $625 $0 Dec 16, 2022
Aug 8, 2022 39067540K RESOLVE CLASS - 1 I OBSERVED IN THE BASEMENT HOUSETRAP THE GROUND ELECTRODE CONDUCTOR IN A STATE OF CORROSION DUE TO EXCESSIVE WATER AN... $800 $0 Mar 24, 2023
Apr 22, 2019 39002249H RESOLVE CLASS - 2 SURFACE BLOW DOWN NOT INSTALLED; CORRECT ALL VIOLATING CONDITIONS, SUBMIT CERTIFICATE OF CORRECTION. $0 $0 Jun 28, 2019
Jul 23, 2018 32097411R RESOLVE CLASS - 2 11A,50A-AS PER CLASS 2(B254) 28-301.1 FAILURE TO MAINTAIN. 11A)SURFACE BLOWDOWN VALVE NOT INSTALLED. 50A)BODY DRAINS ... $0 $0 Sep 7, 2018
Jun 12, 2017 35252338X RESOLVE CLASS - 3 WORK W/O PERMIT. AT TIME OF INSPECTION OBSERVED EXISTING IRON GATE/FENCED AT A HEIGHT OF 8FEET 6INCH,NO PERMITS WERE ... $0 $0 Aug 4, 2017
Jun 12, 2017 35252337Y RESOLVE CLASS - 3 FENCE EXCEEDS PERMITTED HEIGHTS. AT TIME OF INSPECTION OBSERVED EXISTING IRON GATE/FENCE AT A HEIGHT OF 8FEET 6INCH D... $0 $0 Aug 4, 2017
May 16, 2017 35253545N ACTIVE CLASS - 2 SEC. 408.2 DRIPS-FUTURE CONNECTIONS EXIST DOWN STREAM OF APPLIANCE. OBSERVED ON 5-16-17 AT ABOVE ADDRESS FUTURE GAS C... $800 $0 Jul 21, 2017
May 16, 2017 35253546P RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 5-16-17AT ABOVE ADDRESS VENT FOR FRESH AIR IN GAS METE... $250 $0 Jul 21, 2017
May 16, 2017 35253544L RESOLVE CLASS - 2 FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. RE: INSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER PC 1... $0 $0 Jul 7, 2017
May 16, 2017 35260447P RESOLVE CLASS - 1 ELECTRICVAL WORK W/O A PERMIT. OBSERVED AROUND EXTERIOR PERIMETER & INBASEMENT: THE INSTALLATION OF WALL PACK LIGHT F... $1,600 $0 Jul 21, 2017
Feb 17, 2017 32086141M RESOLVE CLASS - 1 51,50B,50C,50E,50G,3A,B, 50A,50D,50F,50H. 50A-FLUE PIPE ELBOW DISCONNECTED; 50B-HOLES, FLUE IMPROPER MAERIAL; 50C- BO... $1,000 $0 Apr 7, 2017
Feb 17, 2017 32086140K RESOLVE CLASS - 2 3. ENTIRE FLUE PIPE IS ROTTED AND HELD TOGETHER WITH FURNACE CEMENT. FAILURE TO MAINTAIN (B254) MUST CORRECT ALL VIOL... $0 $0 Apr 7, 2017
Feb 16, 2016 35171341M RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT FRONT BULKHEAD SKY LIGHTS MISSING WIRE MESH CATCH ALL. A... $0 $0 Apr 1, 2016
Dec 16, 2014 35080442H RESOLVE CLASS - 2 FAILURE TO COMPLY W/COMMISSIONER'S ORDER TO FILE CERTIFICATE OF CORRECTIONS FOR VIOLATIONS 34735282X, 34735284J,35037... $800 $0 Jan 30, 2015
Feb 27, 2014 35078454M RESOLVE CLASS - 2 FAILURE TO MAINTAIN. DEFECT IS: 1-FIRE ESCAPES ARE SEVERLY RUSTED THROUGHOUT 2-RUSTED STEEL LINTELS ABOVE WINDOWS AT ... $500 $0 May 23, 2014
Feb 1, 2014 35078428Z RESOLVE CLASS - 3 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS.CLASS'A' APT NOW BEING OCCUPIED AS FAMILY SHELT... $0 $0 Jun 27, 2014
Jan 15, 2014 35037962H RESOLVE CLASS - 1 FAILURE TO GROUND ELECTRICAL SYSTEMS ON 1/15/14 AT 10:30AM I OBSERVED:1 400AMPS SERVICE SWITCH WAS MISSING GROUND CON... $4,800 $0 Jun 27, 2014
Jan 15, 2014 35009050R RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER B.... $0 $0 Apr 30, 2014
Jan 23, 2009 34735282X RESOLVE CLASS - 2 WORK W/O A PERMIT. WORK NOTED: IN BASEMENT PARTITIONS CREATED FOR 2 ROOMS W/A KITCHEN AND STOVE. REMEDY: OBTAIN PERMI... $800 $0 Mar 20, 2009
Jan 23, 2009 34735283H RESOLVE CLASS - 2 WORK DOESN'T CONFORM TO APPROVED PLANS FOR OB NUMBER 210039876 NOTE: FROM GROUND FL THRU-OUT 5 FL THERE WAS A WALL BU... $250 $0 Mar 20, 2009
Jan 23, 2009 34735284J RESOLVE CLASS - 2 WORK W/O A PERMIT. WORK NOTED: IN HALLWAY ON GROUND LEVEL INSTALLED PLUMBING FIXTURES. TOILET, AND SINK FOR 2 PC BATH... $800 $0 Mar 20, 2009
Aug 10, 2008 34697927J RESOLVE CLASS - 2 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS AT REAR OF BLDG CONSTRUCTION DEBRIS THROUGHOUT APP... $0 $0 Oct 3, 2008
Aug 10, 2008 34697926H RESOLVE CLASS - 1 EXIT PASSAGE WAY TOTAL OBSTRUCTION: EXIT PASSAGE WAY AT REAR OF PROPERTY IS OBSTRUCTED BY CONSTRUCTION DEBRIS. PASSAG... $1,200 $0 Nov 14, 2008
Aug 11, 2003 34397223R RESOLVE Hazardous FAILRUE TO MAINTAIN:DEFECT NOTED:STEEL UNDERGROUNDING FRAME OF STAIRWELL.ROTTED AND STRUCTURAL STABILITY COMPROMISED ... $800 $0 Dec 26, 2003
Dec 4, 2000 34270165J RESOLVE Non-Hazardous FAILURE TO MAINTAIN, DEFECT NOTED DUMB WITER SHAFT OPEN, BOILER RM AREA. REMEDY: FILE PLANS, OBTAIN PERMIT AND APPROV... $180 $0 Feb 2, 2001
Aug 14, 2000 34253009N RESOLVE Hazardous PLUMBING WORK WITHOUT A PERMIT. FOUND IN APARTMENT #2D GAS METER #2232304 TURNED ON WITH NEW GAS PIPE RUN FROM METER ... $800 $0 Jun 15, 2001