ECB violations
114 East 198 Street, Bronx • Block 03315 • Lot 0050
23 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 7, 2025 | 39546774L | ACTIVE | CLASS - 1 | AT THE TIME OF INSPECTION OF A NEW 6 STORY BUILDING ACTIVE JOB SITE I OBSERVED INADEQUATE HOUSEKEEPING AT REAR YARD T... | $1,250 | $0 | Jan 16, 2026 |
| Aug 30, 2025 | 39544286N | RESOLVE | CLASS - 1 | OBSERVED LARGE AMOUNTS OF COMBUSTIBLE MATERIAL, DEBRIS @ ENTRANCE BLOCKING EGRESS TO JOBSITE IN CASE OF EMERGENCY, DE... | $0 | $0 | Nov 7, 2025 |
| Aug 30, 2025 | 39544287P | RESOLVE | CLASS - 2 | OBSERVED A CRACKED SIDEWALK CREATING A TRIP AND FALL HAZARD FOR PEDESTRIANS PASSING BY IN FRONT OF THE ROLLING GATE T... | $0 | $0 | Nov 7, 2025 |
| Aug 30, 2025 | 39544285L | RESOLVE | CLASS - 2 | OBSERVED THE CONSTRUCTION FENCE DISLODGED, PROVIDING ACCESS TO THE CONSTRUCTION SITE. STOP ALL USE, WORK @ ENTRANCE 1... | $1,000 | $0 | Nov 7, 2025 |
| Aug 30, 2025 | 39544283H | RESOLVE | CLASS - 2 | OBSERVED STORAGE ZONE OPEN, W/ GENERATOR ACCESSIBLE TO THE PUBLIC WITH/ EXPOSED ELECTRICAL LINES LEANING TOWARDS THE ... | $0 | $0 | Nov 7, 2025 |
| May 9, 2024 | 39528409Y | RESOLVE | CLASS - 2 | 6 STORY NB AT SUPERSTRUCTURE PHASE. I OBSERVED EXTERIOR EXPOSURE 1 SUPPORTED SCAFFOLD WITH DEBRIS NETTING NOT MAINTAI... | $2,500 | $0 | Jan 7, 2025 |
| May 9, 2024 | 39531938R | RESOLVE | CLASS - 2 | BC 3307.2.1(2014 BC). AT THE TIME OF MY INSPECTION OF A 6-STORY NB AT THE SUPERSTRUCTURE PHASE. I OBSERVED PLASTIC YO... | $0 | $0 | Jan 7, 2025 |
| May 9, 2024 | 39528414Z | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION OF A 6-STORY NB AT THE SUPERSTRUCTURE PHASE. I OBSERVE THE GENERAC MOBILE ELECTRICAL GEN... | $2,400 | $0 | Jan 7, 2025 |
| May 9, 2024 | 39528413R | RESOLVE | CLASS - 2 | 6 STORY NB AT SUPERSTRUCTURE PHASE. I OBSERVED AT EXPOSURE 1 ROADWAY YO-DOCK BARRIERS NOT INSTALLED AS PER BC 3301.1.... | $1,250 | $0 | Jan 7, 2025 |
| May 9, 2024 | 39528415K | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION OF A 6-STORY NB AT THE SUPERSTRUCTURE PHASE. I OBSERVED PLASTIC YO-DOCK AT EXPOSURE 1 RO... | $625 | $0 | Jan 7, 2025 |
| Jan 5, 2024 | 39524556X | RESOLVE | CLASS - 2 | BC 2113.1.6.1: AT TIME OF INSPECTION I OBSERVED CHIMNEY OF ADJACENT PROPERTY AT EXPOSURE 4 WAS NOT VERTICALLY EXTENDE... | $0 | $0 | Apr 19, 2024 |
| Jan 5, 2024 | 39524545K | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION I OBSERVED INADEQUATE HOUSEKEEPING ON 5& 6 STORIES WITH LARGE AMOUNT OF DEBRIS SCATTERED CAUSIN... | $0 | $0 | Mar 15, 2024 |
| Jan 5, 2024 | 39524544Z | RESOLVE | CLASS - 2 | BC 3301.2 : AT TIME OF INSPECTION AT NEW 6 STORY BUILDING ACTIVE JOBSITE I OBSERVED STYROFOAM RESIDUE IN STREET AREAS... | $0 | $0 | Aug 25, 2025 |
| Jan 5, 2024 | 39524546M | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION I OBSERVED STANDING WATER IN BASEMENT DEEPER THEN 3 INCHES CREATING A HEALTH HAZARD TO WORKERS ... | $0 | $0 | Aug 25, 2025 |
| Jan 5, 2024 | 39524547Y | RESOLVE | CLASS - 2 | BC 3301.2 AT TIME OF INSPECTION I OBSERVED HOLES LARGER THAN 2 INCHES CREATING A HAZARDOUS CONDITION FOR WORKERS AND ... | $0 | $0 | Aug 25, 2025 |
| Jan 5, 2024 | 39524548X | RESOLVE | CLASS - 2 | BC 3303.2.4: AT TIME OF INSPECTION AT ACTIVE JOBSITE I OBSERVED INADEQUATE SANITY FACILITIES CONSISTING OF 1 PORT A J... | $0 | $0 | Aug 25, 2025 |
| Jan 5, 2024 | 39524552Z | RESOLVE | CLASS - 2 | BC 3301.13.7 : AT TIME OF INSPECTION AT ACTIVE JOBSITE WITH ACTIVE CONSTRUCTION WORK GOING ON, UPON REQUEST TO SEE SU... | $0 | $0 | Aug 25, 2025 |
| Oct 7, 2022 | 39507328J | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION ON A NON-ACTIVE JOBSITE, I OBSERVED A CONSTRUCTION FENCE IN PLACE AND UPON REVIEW THE FENCE PER... | $0 | $0 | Dec 2, 2022 |
| Oct 7, 2022 | 39507329L | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION ON A NONACTIVE JOBSITE, OBSERVED A CONSTRUCTION FENCE IN PLACE THAT HAS BEEN POORLY MAINTAINED.... | $0 | $0 | Dec 2, 2022 |
| Nov 19, 2021 | 35506039N | RESOLVE | CLASS - 2 | JOBSITE FENCE NOT CONST AS PER SUBSEC.ATO MY INSP OF DEMO JOBSITE,I NOTICED CLOSED JOBSITE.I NOTICED JOBSITE HAS CONS... | $0 | $0 | Feb 18, 2022 |
| Sep 28, 2021 | 35591464N | RESOLVE | CLASS - 2 | PROJECT INFORMATION PANEL MISSING/SIDEWALK SHED PANEL/CONSTRUCTION SIGN NOT PROVIDED OR NOT IN COMPLIANCE WITH SECTIO... | $0 | $0 | Dec 17, 2021 |
| Sep 28, 2021 | 35591463L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.NOTED AT TIME OF INSPECTION OF A 3 STORY DEMOLITIO... | $625 | $0 | Jan 21, 2022 |
| Sep 28, 2021 | 35591465P | RESOLVE | CLASS - 2 | 3309.11 FAILURE TO PROVIDE TREE PROTECTION AT EXP1.NOTED AT TIME OF INSPECTION OF A 3 STORY DEMOLITION JOBSITE,I OBSE... | $0 | $0 | Dec 17, 2021 |