ECB violations
2805 Grand Concourse, Bronx • Block 03315 • Lot 0089
38 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 18, 2026 | 39189016J | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS.... | $1,250 | $1,250 | Feb 26, 2027 |
| May 18, 2026 | 39189017L | ACTIVE | CLASS - 1 | UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. AT TIMES OF INSPECTION, NO ACCESS, NO PERMITS, AND NO CER... | $2,500 | $2,500 | Feb 26, 2027 |
| May 18, 2026 | 39189018N | ACTIVE | CLASS - 1 | UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. AT TIMES OF INSPECTION, NO ACCESS, NO PERMITS, AND NO CER... | $2,500 | $2,500 | Feb 26, 2027 |
| May 18, 2026 | 39189015H | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS.... | $1,250 | $1,250 | Feb 26, 2027 |
| Apr 30, 2026 | 39186779Y | ACTIVE | CLASS - 2 | I OBSERVED IN APT 3D INSTALLATION/REPLACEMENT OF LIGHT FIXTURES, LIGHT SWITCHES AND RECEPTACLES THROUGHOUT THE APARTM... | $1,250 | $1,250 | Jan 29, 2027 |
| Jan 4, 2026 | 39172310J | ACTIVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED MULTIPLE CRACKS BRICKS ALONG WITH SPALLING/MISSING MORTAR JOINTS AT MULTIPLE LOCATIONS... | $2,500 | $2,500 | Oct 23, 2026 |
| Aug 13, 2025 | 39156904R | ACTIVE | CLASS - 2 | FOUND FEDERAL FST-100 DUAL FUEL BURNER, WITH BURNER NOT REGISTERED WITH DOB, APPLICATION #240256897 NEVER SIGNED OFF. | $1,250 | $0 | Feb 13, 2026 |
| Nov 19, 2024 | 39130745N | ACTIVE | CLASS - 2 | CONTRARY TO C-OF-O WHICH INDICATES 1 CELLAR APT: AT TIME OF INSPECTION BDRM AT APT B2 OBSERVED CREATED & OCCUPIED AS ... | $1,250 | $1,250 | Sep 12, 2025 |
| Nov 19, 2024 | 39130746P | ACTIVE | CLASS - 1 | W/O A PERMIT. NOTED: AT CELLAR NORTH & SOUTH AT WEST - WATER & WASTE LINES INSTALLED FOR (2) 3 PC BTHRMS & 2 RESIDENT... | $2,500 | $2,500 | Sep 12, 2025 |
| Nov 19, 2024 | 39130742H | ACTIVE | CLASS - 1 | CONTRARY TO C-OF-O # 47110 WHICH INDICATES 1 JANITOR APT: AT TIME OF INSPECTION - CELLAR NORTH AT WEST CREATED & OCCU... | $2,500 | $2,500 | Sep 12, 2025 |
| Nov 19, 2024 | 39130743J | ACTIVE | CLASS - 1 | W/O A PERMIT. NOTED: AT CELLAR NORTH & SOUTH AT WEST - ELECTRICAL WIRING INSTALLED: 220V LINE IN APT B3 FOR STOVE: 11... | $2,500 | $2,500 | Sep 12, 2025 |
| Nov 19, 2024 | 39130744L | ACTIVE | CLASS - 2 | W/O A PERMIT. NOTED: AT CELLAR NORTH & SOUTH AT WEST - FULL HEIGHT PARTITION WALLS ERECTED TO CREATE 2 BTHRMS; 1 BDRM... | $1,250 | $1,250 | Sep 12, 2025 |
| Oct 16, 2024 | 35484010P | ACTIVE | CLASS - 1 | OCCUPANCY INCONTRARY TO THAT ALLOWED BY C/O AND/OR DEPARTMENT OF BUILDING RECORDS. ILLEGALLY CREATED 2 CLASS "A" APAR... | $2,500 | $2,500 | Apr 18, 2025 |
| Oct 16, 2024 | 35484013K | ACTIVE | CLASS - 2 | OCCUPANCY INCONTRARY TO THAT ALLOWED BY C/O AND/OR DEPARTMENT OF BUILDING RECORDS. ILLEGALLY CREATED CLASS "A" APARTM... | $1,250 | $1,250 | Apr 18, 2025 |
| Dec 9, 2022 | 37024861Z | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $1,250 | Aug 18, 2023 |
| Jul 12, 2017 | 32091111H | ACTIVE | CLASS - 2 | AS PER CLASS 254-36 BURNER NOT REGISTER AS PER DOB RECORDS. CORRECT ALL VIOLATING CONDITIONS & SUBMIT A C OF C. | $250 | $0 | Sep 29, 2017 |
| Jul 19, 2016 | 38244167J | RESOLVE | CLASS - 2 | 59U15, 68B07,68M07. NO TAG STATING DATE OF ANNUAL BRAKE MAINTENANCE, NO ENTRY OF DATE OF ANNUAL BRAKE MAINTENANCE IN ... | $500 | $0 | Nov 18, 2016 |
| May 13, 2013 | 35001907K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES.NOTED AT EXPSOURE 1 (EAST ELEVN) 1-PUSHING OFF OF SHELF ANGLES AT 6/F ... | $250 | $0 | Jul 5, 2013 |
| Jul 18, 2012 | 34984688N | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALLS & APPURTENANCES. NOTED: (EXPOSURE 1/EAST ELEVN) A/PUSHING OFF OF SHELF ANGLES AT 6... | $500 | $0 | Sep 7, 2012 |
| Apr 15, 2011 | 36016577P | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIA NCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EX... | $2,000 | $0 | Sep 9, 2011 |
| Mar 3, 2011 | 34872207R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG WEST ELEVATION(EXP#3)OBSERVE BLOCKS OF WOOD,MASONRY BRICKS IMPROPERLY INSTALLED UND... | $500 | $0 | Dec 15, 2011 |
| Jul 12, 2010 | 36014151Z | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/CODE PROVISIONS:PERIODIC INSPECTION OF EXTERI... | $2,000 | $0 | Oct 15, 2010 |
| Nov 27, 2009 | 36010649H | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXT... | $4,000 | -$1,221 | Mar 19, 2010 |
| Jan 30, 2009 | 36008313L | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF E... | $800 | $0 | Sep 21, 2009 |
| Nov 3, 2008 | 38192765H | RESOLVE | CLASS - 2 | 23X10.45H10.52M07.53R14.23X10 REPAIR FIREMAN SERVICE PHASE 1 45H10 REPAIR GOVERNOR TENSION SHEAVE WORN BUSHING 52M07 ... | $500 | $0 | Jan 16, 2009 |
| Mar 7, 2008 | 38181039J | RESOLVE | Non-Hazardous | 85U05.86U05.14M10 | $350 | $0 | May 2, 2008 |
| Oct 11, 2006 | 38161801Y | RESOLVE | Non-Hazardous | 5-E-10/16-H-10/25-W-10/59-X-10/64-X-10/85-R-5/86-R-5/16-REPAIR 1 FLR DOOR CHECK/85-REOVED ILLEGAL TAG WITH 5 YR TEST ... | $0 | $0 | May 18, 2007 |
| Mar 10, 2006 | 38158080X | RESOLVE | Non-Hazardous | 20I11/5L10/12Q7/33L10/5L10/9L10/39P7. 20/I CAR DOOR VISION PANEL. 5/L GAP BETWEEN CAR DOOR & CAB IS TO LARGE. 12/Q LI... | $0 | $0 | Apr 28, 2006 |
| Mar 2, 2005 | 38151478Y | RESOLVE | Non-Hazardous | 14M07/05L10/85U05/55Y10/58B07/21Q03/66O02/12X10/71Q03/12Q03. 05-EXCESSIVE GAP AT RETURN POST AND RUBBING IN SADDLE.58... | $350 | $0 | Jan 20, 2006 |
| Jan 7, 2005 | 38156927N | RESOLVE | Non-Hazardous | 14M10/85U15/21Q03/40D06 21-BASEMENT | $350 | $0 | Jan 20, 2006 |
| Jan 22, 2000 | 38093891P | RESOLVE | Non-Hazardous | 50Y11,18Q03,57O02,15#11. SEAL REPAIR OIL LEAK, BASEMENT LEAK, LOBBY DOOR NOT SELF CLOSING. | $2,500 | $0 | Mar 10, 2000 |
| Jun 10, 1998 | 38075531M | RESOLVE | Non-Hazardous | 30O2,57O2,17I12,15T16. 30-CLEAN SHAFTWAY. 57-CLEAN PIT. 17-REPLACE CAB DOOR GLASS. 15-LABEL HOISTWAY DOORS. | $0 | $0 | Jul 24, 1998 |
| Jan 16, 1998 | 38069553M | ACTIVE | Non-Hazardous | 75U5,11X11,36T16,36X12,35O2,32M3,50O2,37O2,10X11,30O2,3O2,25B1,57O2. 36X-REPLACE DOOR KNOB. 10-BYPASSING FL STOPS. | $2,500 | $0 | Mar 13, 1998 |
| Aug 20, 1997 | 38062965R | ACTIVE | Non-Hazardous | 10B14M22D30O35I37H57O57P75U, 10- PUSH BUTTON NOT WORKING ON THE 6TH FLOOR 30- CLEAN CAR TOP 35-REPLACE DOOR LOCK 37- ... | $1,000 | $0 | Dec 12, 1997 |
| May 13, 1994 | 38042109X | RESOLVE | Non-Hazardous | 06,06,08,14,21,22,35,74,74,B,B,V,I,X,D,P,M,H, (06) RENEW CAR DOOR GIBBS (06) ADJUST CAR DOORS (35) PROVIDE ACCESS TO ... | $200 | $0 | Jul 29, 1994 |
| Aug 21, 1992 | 38028952Z | RESOLVE | Non-Hazardous | 37G,37H,35O,35R,73X, (37) PROPERLY FUSE CONTROLLER (37) RENEW WORN CARBONS & CONTACTS WHERE NECESSARY. (35) REMOVE UN... | $200 | $0 | Jan 6, 1994 |
| Feb 18, 1992 | 38021732P | RESOLVE | Non-Hazardous | 08V,37G,35O | $1,000 | $0 | Apr 24, 1992 |
| Nov 22, 1991 | 34064162R | RESOLVE | Non-Hazardous | ILLEGAL USE IN A RESIDENTIAL DISTRICT:HANING PLACED AN ADVERTISING SIGN OVER THE FRONT ENTRANCE OF MULTIPLE DWELLING ... | $0 | $0 | Jan 24, 1992 |