| Jan 30, 2026 | 39175428Z | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING FACADE IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED THE FACADE AT EXPOSUR... | $6,250 | $6,250 | Sep 4, 2026 |
| Jul 29, 2025 | 39155313K | ACTIVE | CLASS - 1 | FRONT OF BUILDING (EXP1) MORTAR MISSING IN A FEW AREAS, IN BOTH COURTYARD NOT IN USE FOR EXIT' 2 PARAPET WALLS LEANIN... | $12,500 | $12,500 | Oct 3, 2025 |
| May 27, 2025 | 39148975Y | RESOLVE | CLASS - 3 | OBSERVED WATER DAMAGES TO WALLS AND CEILING IN APARTMENT#6D BATHROOM AND BEDROOMS FROM ROOF AND WINDOW LINTELS., REPA... | $0 | $0 | Aug 1, 2025 |
| Aug 26, 2024 | 37029003P | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #35635276H ISSUED ON 11/6/2021, AND FAILURE TO FILE ... | $1,250 | $1,250 | Dec 4, 2025 |
| Jun 17, 2024 | 39117095Y | RESOLVE | CLASS - 2 | FOUND A ROCKMILL MP-150 BOILER PILOT GAS LINE OPEN END/ABOUT 4FEET OF TEMPORARY ALUMINUM TUBING USE FOR GAS PILOT/FRE... | $0 | $0 | Aug 30, 2024 |
| Nov 15, 2023 | 39099443P | RESOLVE | CLASS - 2 | OBSERVED ON FIFTH FLOOR IN APARTMENTS 5A AND 5C HAVING A FUTURE AND OPEN END GAS LINE IN THE KITCHEN WHICH IS CONTRAR... | $0 | $0 | Jun 17, 2024 |
| Mar 23, 2022 | 35647369P | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.AT THE TIME OF INSPECTION OBSERVED OBJECT(SUCH AS FLOWER TOP BOX)ON F... | $1,250 | $0 | Jul 1, 2022 |
| Nov 6, 2021 | 35635276H | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCE AT TIME OF INSPECTION OBSERVED AT EXPOSURE#1(BY MINERVA... | $1,250 | $0 | Feb 4, 2022 |
| May 20, 2020 | 37018998Z | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7A & 8A REPORT CRITICALEXAMINATION DOCUMENTING CONDITION OF EXTERIOR W... | $0 | $0 | Dec 17, 2021 |
| May 18, 2018 | 37010602R | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APPU... | $1,250 | $0 | Oct 26, 2018 |
| Dec 15, 2017 | 35293424N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. @ TIME OF INSP OF APT 1-L OBSERVED SEVERAL LOCATIONS OF THE FLOOR ... | $1,000 | $0 | Feb 2, 2018 |
| Aug 11, 2016 | 37001187Y | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... | $2,000 | $0 | Jun 16, 2017 |
| May 10, 2016 | 38242520M | RESOLVE | CLASS - 1 | 02L10,05L10,40P16. 05L10- CAB DOOR RESTRICTOR NOT WORKING (REPAIR) | $1,000 | $0 | Sep 2, 2016 |
| Sep 21, 2015 | 36023234Z | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE WITH CODEPROVISIONS: PERIODIC INSPECTION OF EXTERIOR WAL... | $4,000 | $0 | Mar 4, 2016 |
| Aug 29, 2015 | 35160101J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING ASNOTED:AT TIME OF INSPECTION ONAN OCCUPIED ON AN 6STORY BUILDING OBSERVED AT E... | $2,500 | $0 | Oct 16, 2015 |
| Aug 27, 2015 | 35133518L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING. WEST ELEVATION EXP#1 CRACKED & DETERIORATING SILLS ON 2ND FLR WINDOWS,2 WOOD B... | $250 | $0 | Sep 9, 2016 |
| May 27, 2014 | 36019267N | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... | $800 | $0 | Sep 19, 2014 |
| Jun 3, 2009 | 38203795J | RESOLVE | CLASS - 2 | 12Q3.40P16.77X10 03M11 REPLACE HANDRAIL IN CAR 40P16 PROVIDE ACCESS TO M/R SO THAT A COMPLETE INSPECTION CAN BE MADE ... | $0 | $0 | Jul 24, 2009 |
| Jul 22, 2008 | 38189324P | RESOLVE | CLASS - 3 | 15I11,11X10,24X10,35R06,60R03,61T07,70O02,100X10,100M05. REPAIR INDICATORS IN CAR STATION REPAIRS INDICATES IN HALL B... | $0 | $0 | Sep 19, 2008 |
| Apr 30, 2008 | 38184271H | RESOLVE | Non-Hazardous | 02X10.14M11.15M11.38O02.39P16.40T07.71Q03. 02X10 REPAIR COMMUNICATION IN CAR TELEPHONE 40T07 PROVIDE SIGN FOR MOTOR R... | $350 | $0 | Jan 30, 2009 |
| Dec 30, 2007 | 38179885X | RESOLVE | Non-Hazardous | 14M07,15M07,84L10,66O02,72H10,40D06,59B07.84L10-INTERCOM INSIDE ELEVATOR DOESN'T WORK PROVIDE WORKING INTERCOM..72H10... | $180 | $0 | Mar 21, 2008 |
| Jun 20, 2006 | 38159911M | RESOLVE | Non-Hazardous | 12-B-07,84-O-02/12-B-07-PROVIDE PROPER LIGHTING INSIDE ELEVATOR/84-O-02-CLEAN BOTTELS & PAPER FROM LIGHT FIXTURES | $180 | -$180 | Aug 4, 2006 |
| Apr 14, 2004 | 38146539M | RESOLVE | Non-Hazardous | 83O02/15M07/84M07/10H10/02X10/11X10/86U05/51O02/55Y13/51Q03/39X10/58B07/20Q03/12Q03/83U15/25M07/25P16/34R09/39Q03 11-... | $10,000 | $0 | May 28, 2004 |
| Aug 28, 2003 | 38140862P | RESOLVE | Non-Hazardous | 03I10,25P07,16E01,66O02,34R09,40T07,55Y10. #25 AS PER CODE #16 LOBBY FL #34 ON SIDE OF SHAFTWAY. | $0 | $0 | Oct 22, 2004 |
| Feb 26, 2002 | 38121630M | RESOLVE | Non-Hazardous | 21X11-22#6-74I11-31Q3-57O2-17M12-35P17. 22-AS PER CODE 74- WORK LIGHT 17-CLASS. | $0 | $0 | Apr 19, 2002 |
| Feb 9, 2000 | 38094319Z | RESOLVE | Non-Hazardous | 57Z09,17Q03,50Y11,62Q03,31Q03. 17- CAB DOOR GLASS 62- JUNCTION BOX 31- PIT AREA 4X4 BOX NAD OTHER WIRES EXPOSED | $0 | $0 | Mar 31, 2000 |
| May 22, 1999 | 38087112X | RESOLVE | Non-Hazardous | 14M 75U 57O 74M 22P 75U TSG TOP OF CAR 74M PROVIDE COVER BOX UNDER CAR | $0 | $0 | Jul 9, 1999 |
| Aug 11, 1997 | 38061823R | RESOLVE | Non-Hazardous | 50Y23U25U18Q57O36T | $0 | $0 | Oct 10, 1997 |
| Oct 17, 1994 | 38044097R | RESOLVE | Non-Hazardous | 13M,14I,35P,57O | $0 | $0 | Dec 16, 1994 |