ECB violations
Bainbridge Avenue, Bronx • Block 03327 • Lot 0001
128 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 8, 2011 | 38216205N | RESOLVE | CLASS - 2 | 52H11,52M07,70O02,71Q03,77Q03. 52M07- PROVIDE SPIN OUT FOR HOIST CABLES. 77Q03- INSTALL GUARD FOR LIGHT UNDER CAR. | $2,500 | $0 | Jun 17, 2011 |
| Mar 8, 2011 | 38215613H | RESOLVE | CLASS - 2 | 52H11,52M07,70O02,71Q03,77Q03 52M07-PROVIDE SPIN OUT FOR HOIST CABLES 77Q03-INSTALL GUARD FOR LIGHTS UNDER CAR | $0 | $0 | Apr 29, 2011 |
| Mar 8, 2011 | 38215612X | RESOLVE | CLASS - 2 | 39O02,70O02,71Q03,77Q03 77Q03-INSTALL GUARD FOR LIGHT UNDER CAR. | $0 | $0 | Apr 29, 2011 |
| Mar 8, 2011 | 38215611Y | RESOLVE | CLASS - 2 | 02X10,39O02,52M07,70O02,71Q03,77Q03 52M07-PROVIDE CROSBY FOR HOIST CABLE SPIN OUT 77Q03-INSTALL GUARD FOR LIGHT UNDER... | $0 | $0 | Apr 29, 2011 |
| Jun 9, 2010 | 38211260N | RESOLVE | CLASS - 2 | 10H11,11I10,14M07,15I11,17H11,35Q03,39Q02,39Q03,60Q03,61T07,68M07,69M07,70O02,70Y02,100Y13. 11I- REPAIR DOOR CLOSE BU... | $2,500 | $0 | Jul 30, 2010 |
| Dec 8, 2008 | 38199575Z | RESOLVE | CLASS - 2 | 52O02,58Y13,77Q03. 77Q03-INSTALL GUARD FOR LIGHT UNDER CAR. | $0 | $0 | Jan 30, 2009 |
| Jul 11, 2007 | 38167697K | RESOLVE | Non-Hazardous | 47Y10/39Y2/.47Y10-REPAIR PUMP UNIT TO STOP OIL LEAK.39Y2-CLEAN OIL FROM MOTOR ROOM FLOOR. | $0 | $0 | Sep 7, 2007 |
| Sep 27, 2005 | 34401913N | RESOLVE | Non-Hazardous | SITE SAFETY. APPROVED PLANS NOT AVAILABLE FOR INSPECTION. (NO APPROVED CD 5 FOR OUTRIGGER BEAM USING A TWO POINT SUSP... | $500 | $0 | Mar 3, 2006 |
| Sep 1, 2004 | 38148588H | RESOLVE | Non-Hazardous | 83## RESTORE TO SERVICE OR FILE BUILDING NOTICE FOR REMOVAL | $350 | -$350 | Jun 24, 2005 |
| Sep 1, 2004 | 38148589J | RESOLVE | Non-Hazardous | FILING A FALSE CERTIFICATED WITH N.Y.C. DEPT OF BLDGS PURSANT TO SECTION 26-126.2 RESPONDENT FILED A CERTIFICATE OF C... | $2,500 | $0 | Dec 2, 2005 |
| Apr 17, 2002 | 32026623K | RESOLVE | Non-Hazardous | 49/BQ9-27-147 NEBRASKA HIGH PRESSURE WASTE HEAT BOILER NB#3956+3954 INSTALLED WITHOUT A BL BOILER PERMIT ISSUED BY DO... | $500 | $0 | Oct 21, 2003 |
| Aug 7, 2000 | 38107380H | RESOLVE | Non-Hazardous | 73X11,36R09.73-RESTORE TO SERVICE FOR A COMPLETE INSPECTION BY THIS DEPARTMENT.36-REMOVE ALL EQUIPMENT NOT RELATED TO... | $350 | $0 | Sep 22, 2000 |
| Aug 2, 2000 | 38107376P | RESOLVE | Non-Hazardous | 35Y11 57Z09 35-REPAIR OIL LEAK IN MOTOR ROOM | $180 | $0 | Sep 22, 2000 |
| Aug 2, 2000 | 38107377R | RESOLVE | Non-Hazardous | 50Y11 50-DRECKTOR AND REPAIR -OIL LEAK | $180 | $0 | Sep 22, 2000 |
| Aug 1, 2000 | 38106750L | RESOLVE | Non-Hazardous | 74U05 57B07 57-REINSTALL MISSING FALK -HORE COVER | $180 | $0 | Sep 22, 2000 |
| Jul 31, 2000 | 38106748M | RESOLVE | Non-Hazardous | 54X11 | $350 | $0 | Sep 22, 2000 |
| Jul 31, 2000 | 38106746Z | RESOLVE | Non-Hazardous | 02L11 30O02 35B11 32#09 30-CLEAN HOISTRUAY, CAR RAILS, CWT RAIES AND ALL EQUIPMENT 35-PATCH ALL HOLES MOTOR ROOM FLOO... | $350 | $0 | Sep 22, 2000 |
| Jul 31, 2000 | 38106747K | RESOLVE | Non-Hazardous | 50V14 30O02 35Q03 30-CLEAN HOISTWAY, CAR RAILS, CUT RAILS + BRALKETS AND 35-4X4 COVER VR MOTOR ROOM, WIRESEXPORED | $350 | $0 | Sep 22, 2000 |
| Jun 16, 1999 | 38087825X | RESOLVE | Non-Hazardous | 51Y-CLEAN OUTER AREA REPAIR OIL LEAK AS NEEDED. | $180 | $0 | Aug 13, 1999 |
| Jun 16, 1999 | 38087824Y | RESOLVE | Non-Hazardous | 64M,57A,57O, 64-M-03 INSTALL COMP.DRAIN GUIDE 57-A-11 REPAIR PIT WALL, CLEAN AND REMOVE ITEMS FROM PIT. | $350 | $0 | Aug 13, 1999 |
| Jun 16, 1999 | 38087823M | RESOLVE | Non-Hazardous | 57O-CLEAN PIT AND REMOVE ALL ITEMS NOT RELATED TO ELEVATOR. | $180 | $0 | Aug 13, 1999 |
| Jun 16, 1999 | 38087822K | RESOLVE | Non-Hazardous | 51L,46A,39H, 46-A-02 CLEAN HOIST CABLES FOR REINSPECTION. | $350 | $0 | Aug 13, 1999 |
| Jun 14, 1999 | 38087816Y | RESOLVE | Non-Hazardous | 57O,3O. CLEAN CAR TOP. | $180 | $0 | Jul 23, 1999 |
| Jun 14, 1999 | 38087815M | RESOLVE | Non-Hazardous | 50O. | $180 | $0 | Jul 23, 1999 |
| Jun 14, 1999 | 38087814K | RESOLVE | Non-Hazardous | 50O. | $180 | $0 | Jul 23, 1999 |
| Jun 14, 1999 | 38087812R | RESOLVE | Non-Hazardous | 46K,47H,57O,50O. GOV CABLE IS WORN AND RUST IS VISABLE. | $350 | $0 | Jul 23, 1999 |
| Jun 14, 1999 | 38087813Z | RESOLVE | Non-Hazardous | 2L,47H,57O. GOV CABLES ARE WORN AND SOME RUST IS VISABLE. | $350 | $0 | Jul 23, 1999 |
| Jun 14, 1999 | 38087818H | RESOLVE | Non-Hazardous | 57Y, CLEAN PIT OIL LEAK AND REPAIR ALL NECESSARY OIL LEAKS. | $350 | $0 | Jul 23, 1999 |
| Jun 14, 1999 | 38087817X | RESOLVE | Non-Hazardous | 46A,57A. CLEAN PIT AND REMOVE EXTRA TRAVELLING CABLE FROM PIT. | $350 | $0 | Jul 23, 1999 |
| Jun 11, 1999 | 38087804R | RESOLVE | Non-Hazardous | 46A. | $0 | $0 | Aug 4, 1999 |
| Jun 11, 1999 | 38087801L | RESOLVE | Non-Hazardous | 50Y,39H,57O,55Q. | $0 | $0 | Jul 23, 1999 |
| Jun 11, 1999 | 38087803P | RESOLVE | Non-Hazardous | 46A. | $0 | $0 | Jul 23, 1999 |
| Jun 11, 1999 | 38087805Z | RESOLVE | Non-Hazardous | 3O,46A. CLEAN CAR TOP. | $0 | $0 | Jul 23, 1999 |
| Jun 11, 1999 | 38088310L | RESOLVE | Non-Hazardous | 03O 46A 03 0 02 CLEAN CAR TOP | $2,500 | $0 | Aug 27, 1999 |
| Jun 11, 1999 | 38088306Z | RESOLVE | Non-Hazardous | 50T 39H 57O 55Q | $2,500 | $0 | Aug 27, 1999 |
| Jun 11, 1999 | 38088307K | RESOLVE | Non-Hazardous | 50O 570 31Q 46A 31 Q 03 TOP OF CAR ENTERRUTOR TO GATE OPEN ELECTRICAL WIRED EXPOSED | $2,500 | $0 | Aug 27, 1999 |
| Jun 11, 1999 | 38088308M | RESOLVE | Non-Hazardous | 46A | $2,500 | $0 | Aug 27, 1999 |
| Jun 11, 1999 | 38088309Y | RESOLVE | Non-Hazardous | 46A | $2,500 | $0 | Aug 27, 1999 |
| Jun 11, 1999 | 38087802N | RESOLVE | Non-Hazardous | 50O,57O,31Q,46A, TOP CAR GATE MOTOR TO GATE OPER ELECTRICAL WIRES EXPOSED. | $0 | $0 | Aug 4, 1999 |
| Jun 10, 1999 | 38088311N | RESOLVE | Non-Hazardous | 53L 47A 35A 50O 35 A 11 MACHINE RM ENTRANCE PLATFORM SUPPORTED BY WOOD NEEDS REPAIR | $2,500 | $0 | Aug 27, 1999 |
| Jun 10, 1999 | 38087625L | RESOLVE | Non-Hazardous | 53L12, 47A14, 35A11, 50O02, 35A11 MACHINE ROOM ENTRANCE PLATFORM SUPPORTED BY WOOD, NEEDS REPAIR | $0 | $0 | Aug 27, 1999 |
| Aug 8, 1997 | 38061816Z | RESOLVE | Non-Hazardous | 03O46L07A | $1,000 | $0 | Sep 26, 1997 |
| Aug 8, 1997 | 38061819Y | RESOLVE | Non-Hazardous | 73X RESTORE DEVICE BACK TO SERVICE SO A PROPER INSPECTION COULD BE MADE. | $1,000 | $0 | Sep 26, 1997 |
| Aug 8, 1997 | 38061818M | RESOLVE | Non-Hazardous | 03O57O07A | $1,000 | $0 | Sep 26, 1997 |
| Aug 8, 1997 | 38061817K | RESOLVE | Non-Hazardous | 46H07A54I39H | $1,000 | $0 | Sep 26, 1997 |
| Aug 6, 1997 | 38061814P | RESOLVE | Non-Hazardous | 57O2,3O2,1L11. | $1,000 | $0 | Dec 12, 1997 |
| Aug 6, 1997 | 38061815R | RESOLVE | Non-Hazardous | 2X11,7A10,57O2,3O2. | $1,000 | $0 | Dec 12, 1997 |
| Aug 6, 1997 | 38061813N | RESOLVE | Non-Hazardous | 3O2,57O2,22D6,1L11,50Y2,73X. PLEASE RETURN THIS DEVICE TO SERVICE SO APROPER INSPECTION COULD BE MADE. | $1,000 | $0 | Dec 12, 1997 |
| Jul 30, 1997 | 38061811J | RESOLVE | Non-Hazardous | 01L,57O,03O,22D, ALARM BELL INOP, SECURE TOP EXIT COVER. | $0 | $0 | Sep 26, 1997 |
| Jul 30, 1997 | 38061806P | RESOLVE | Non-Hazardous | 03O,57O,50Y,75U, H-TOP EXIT COVER SW ILLEGALLY BLOCKED IN | $1,000 | $0 | Sep 26, 1997 |