Maintenance code violations
East 212 Street, Bronx • Block 03329 • Lot 0040
2,268 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Apr 9, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST... | 2B | May 14, 2019 |
| Apr 8, 2019 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE... | 2B | Jul 12, 2019 |
| Apr 8, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILI... | 2C | May 13, 2019 |
| Apr 8, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILI... | 2C | Jul 12, 2019 |
| Apr 8, 2019 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 2C, 4th... | 2C | May 13, 2019 |
| Apr 8, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST... | 2B | May 13, 2019 |
| Apr 8, 2019 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT WASHBASIN IN THE BATHROOM LOCATED AT APT 2... | 2C | May 13, 2019 |
| Apr 8, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILI... | 2C | May 13, 2019 |
| Apr 8, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FROM EAST... | 2C | May 13, 2019 |
| Apr 8, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILI... | 2C | Jul 12, 2019 |
| Mar 25, 2019 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFFECTIVE LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM N... | 3B | Apr 29, 2019 |
| Mar 25, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE ENTIRE APARTMENT L... | 3B | Apr 29, 2019 |
| Mar 25, 2019 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd ... | 3B | Apr 15, 2019 |
| Mar 25, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR OVER CEILING IN THE... | 3B | Apr 29, 2019 |
| Mar 25, 2019 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FRO... | 3B | Apr 29, 2019 |
| Mar 25, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW UPPER SASH COUNTER BALANCE IN THE BATHROOM LOCATED ... | 3B | Apr 29, 2019 |
| Mar 25, 2019 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFFECTIVE LOCATED AT APT 3B, 3rd STORY, ... | 3B | Apr 29, 2019 |
| Mar 25, 2019 | C | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS IN THE ENTIRE APARTMENT LOCATED AT APT 3B,... | 3B | Apr 15, 2019 |
| Mar 25, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE EAST BASE CABINET IN THE KITCHEN LOCATED AT APT 3B, 3rd S... | 3B | Apr 29, 2019 |
| Mar 19, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE HANDLE RADIATOR VALVE IN THE 1st ROOM FROM EAST LOCATED A... | 3I | Apr 23, 2019 |
| Mar 19, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT RADIATOR IN THE 1st RO... | 3I | Apr 23, 2019 |
| Mar 19, 2019 | B | VIOLATION CLOSED | § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE TOILET TANK IN THE BATHROOM LOCATED AT APT 3I, 5th STORY, 1st APAR... | 3I | Apr 23, 2019 |
| Mar 18, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1... | F | Jun 21, 2019 |
| Mar 18, 2019 | B | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT APT ENTRA... | F | Apr 22, 2019 |
| Mar 18, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT UPPER WINDOW SASH IN THE KITCHEN LOCATED AT APT ... | F | Apr 22, 2019 |
| Mar 18, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT UPPER WINDOW SASH IN THE 1st ROOM FROM EAST AT N... | F | Apr 22, 2019 |
| Mar 18, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LO... | F | Jun 21, 2019 |
| Mar 18, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE P... | F | Jun 21, 2019 |
| Mar 18, 2019 | A | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FRO... | F | Jun 21, 2019 |
| Mar 18, 2019 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF WASHING MACHINE AT PUBLIC HALL, 3rd STORY | — | Apr 22, 2019 |
| Mar 18, 2019 | B | VIOLATION CLOSED | § 27-2038 ADM CODE PROVIDE ADEQUATE LIGHTING FOR ELECTRICAL LIGHT FIXTURE AT CEILING AT PUBLIC HALL, 4th STORY, SECTI... | — | Apr 22, 2019 |
| Mar 18, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM AT SOUTH WALL IN THE PRIVATE HALLWAY LOCATED AT A... | 3I | Apr 22, 2019 |
| Mar 18, 2019 | B | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT APT ENTRA... | 3I | Apr 22, 2019 |
| Feb 20, 2019 | A | VIOLATION CLOSED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... CEILING APPROX 1 SQ FT IN THE BA... | 2B | May 26, 2019 |
| Feb 20, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATH... | 2B | Mar 27, 2019 |
| Feb 15, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ... WOOD FLOOR IN THE 2nd ROOM FROM ... | 4G | Mar 22, 2019 |
| Feb 15, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ... WOOD DOOR IN THE 1st ROOM FROM EAST AT SOUTH LOCATED ... | 4G | May 21, 2019 |
| Feb 15, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ... GLASS AT LOWER SASH EAST WINDOW IN THE 1st ROOM FROM ... | 4G | Feb 23, 2019 |
| Feb 15, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ... WOOD FLOOR IN THE 1st ROOM FROM ... | 4G | Mar 22, 2019 |
| Feb 15, 2019 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Mar 22, 2019 |
| Feb 15, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RATED MATERIAL AT THE CEILING A... | — | Mar 22, 2019 |
| Feb 15, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ROTTING WOOD BASE AT SKYLIGHT AT THE... | — | Mar 22, 2019 |
| Feb 15, 2019 | B | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LEADING TO T... | — | Mar 22, 2019 |
| Feb 15, 2019 | C | VIOLATION CLOSED | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | 4G | Mar 15, 2019 |
| Feb 15, 2019 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, ... | — | May 21, 2019 |
| Feb 15, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RATED MATERIAL AT THE NORTH SOU... | — | Mar 22, 2019 |
| Feb 15, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ... WOOD DOOR FRAME IN THE BATHROOM ... | 4G | Mar 22, 2019 |
| Feb 14, 2019 | B | VIOLATION CLOSED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 5th ... | 4G | Mar 21, 2019 |
| Feb 13, 2019 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL AT PUBLIC HAL... | — | May 19, 2019 |
| Feb 13, 2019 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSE HOLD ITEM AT PUBLIC HALL, 4th STORY | — | Mar 20, 2019 |