285-287 East 236 Street, Bronx
Bronx • Block 03377 • Lot 0059 • Zip: 10470
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 4 days ago- Grand Central 50 min 12 walking, 38 riding
- Union Square 54 min 12 walking, 42 riding
- Times Square 56 min 12 walking, 44 riding
- Fulton Street 60 min 12 walking, 48 riding
- Penn Station 61 min 12 walking, 49 riding
- Downtown Brooklyn 67 min 12 walking, 55 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Bus
Places nearby
Activity
Sales, filings, permits and violations from every dataset, in one order.
2022
-
DOB violation Mar 30, 2022
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
DOB violation Mar 30, 2022
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
DOB violation Mar 30, 2022
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
DOB violation Mar 30, 2022
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
CLASS - 1
FAIL TO INSTITUTE & MAINTAIN SAFETY MEASURES.AT TIME OF INSPECTION OF 3 STORY MIXED USE BLDG I OBSERVED HOLES & ROTTE...
-
CLASS - 1
BC3301.2 CONTROL ACCESS ZONE.AT TIME OF INSPECTION AT 3 STORY MIXED USE BLDG I OBSERVED OPEN AREAS UNPROTECTED AT 1ST...
-
CLASS - 1
GUARDRAIL SYSTEM.AT TIME OF INSPECTION AT 3 STORY MIXED USE BLDG I OBSERVED ON 1ST & 2ND STORY OPEN WINDOW W/OUT ANY ...
-
CLASS - 1
HANDRAILS.AT TIME OF INSPECTION AT 3 STORY MIXED USE BLDG I OBSERVED MISSING HANDRAIL FROM 1ST STORY TO BASEMENT.FAIL...
2021
2019
-
DOB violation Nov 8, 2019
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
2018
2016
-
HPD violation Jan 15, 2016
Class C
§ 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED ON FRONT GATE TO BUIL...
2014
-
HPD violation May 23, 2014
Class B
§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE HOLE AT WOOD FLOOR BY THE RADIAT...
-
HPD violation May 22, 2014
Class A
§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD DOOR FRAME IN THE BATHROOM LOCATED AT APT 3FL, 3r...
-
HPD violation May 22, 2014
Class A
§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW BALANCE TO LOWER SASH IN THE 3rd ROOM FROM NORT...
-
HPD violation May 22, 2014
Class B
§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW BALANCE TO LOWER SASH IN THE 2nd ROOM FROM NORT...
-
HPD violation May 22, 2014
Class A
§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW BALANCE TO LOWER SASH IN THE BATHROOM LOCATED A...
2013
-
Alteration Type II
NEW & RELOCATED PLUMBING FIXTURES IN CONJUNCTION WITH FIRE REPAIR APPLICATION, NEW/RELOCATED BAR
-
Alteration Type II
REPAIR OF FIRE DAMAGE, REPLACE CEILING JOISTS, NEW CEILING, NEW PARTITIONS AND SHEETROCK
-
Alteration Type II
INSTALL SIDEWALK FENCE IN CONJUNCTION WITH EMERGENCY REPAIR OF FIRE DAMAGE
-
Alteration Type II
REMOVE SCREW JACKS AND 4 X 4 WOOD COLUMNS SET IN CELLAR TO BRACE FLOOR FOR EQUIPMENT ON 1ST FLOOR, SINCE REMOVED. JAC...
2012
-
CLASS - 1
WORK W/O A PERMIT. WORK NOTED: VERTICAL SHORING COMPOSED OF 8 METAL SCREW JACKS 7' HIGH AT APPROX 3'-6" ON CENTER - A...
-
CLASS - 1
WORK W/O A PERMIT. WORK NOTED: VERTICAL SHORING COMPOSED OF 3 WOOD 4X4COLUMNS 7'6" HIGH AT APPROX 3'6" ON CENTER - BE...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records