Sales, filings, permits and violations from every dataset, in one order.
2018
-
DOB violation Apr 6, 2018
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
2016
-
New Building
-
Alteration Type II
-
Alteration Type III
2015
-
Alteration Type II
INSTALLATION OF 2 ROOF MOUNTED GAS FIRE HVAC UNITS (5 TONS AND 7.5 TONS) ALL WORK FILED IN CONJUNCTION WITH NB JOB # ...
-
Alteration Type II
INSTALL 3 GAS FIRE BOILERS. 1 IN CELLAR AND 2 OTHER IN 2ND FLOOR, ALL WORK IN CONJUNCTION WITH NB# 210025907 NO CHANG...
-
DOB violation Mar 3, 2015
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
2014
-
DOB violation Jan 29, 2014
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2013
-
CLASS - 1
NEW BLDG OCCUPIED W/O A VALID C/O. NOTED: NB #210025907 HAS NOT BEEN SIGNED-OFF & IS OCCUPING THE 2ND FL AS 2 CLASS'A...
2012
2009
-
CLASS - 1
SEC. 3301.2. FAILURE TO PROVIDE 3'6" GUARD RAIL OR EQUIPMENT AROUND ALL OPENINGS. AT INSTALLATION OF RETAINING WALL P...
-
CLASS - 2
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS. BOTTOM OF SLAB ON PLANS CALL FOR 11' HOWEVER CELLAR INSTALL...
-
CLASS - 2
SEC. 3309.4. FAILURE TO PERFORM INSPECTION AND DOCUMENT CONDITIONS OF EXISTING STRUCTURES ADJOINING AN EXCAVATION IN ...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records