ECB violations
Ms 337, Bronx • Block 03718 • Lot 0001
122 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 18, 2018 | 35335369M | RESOLVE | CLASS - 2 | REISSUE #35271172Z FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION OBSERVED IN BO... | $0 | $0 | Nov 2, 2018 |
| Jun 23, 2017 | 35271172Z | RESOLVE | CLASS - 2 | REISSUE# 35221257M. FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER (INTERIOR). NOTED: IN THE BOILER ROOM FLR (PIT)... | $0 | $0 | Nov 3, 2017 |
| Nov 14, 2016 | 35221257M | RESOLVE | CLASS - 2 | REISSUE #35147595M FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.(INTERIOR) NOTED @BOILER ROOM (PIT) & VARIOUS LO... | $0 | $0 | Jan 20, 2017 |
| Sep 22, 2015 | 35147596Y | RESOLVE | CLASS - 2 | FAIL TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER: USE PROB DOOR/HARDWARENOTE:@4TH STORY STAIRS B,D, AND E CHAIN AND PAD... | $0 | $0 | Jan 8, 2016 |
| Sep 22, 2015 | 35147595M | RESOLVE | CLASS - 2 | REISSUE NOV #35107198M FAIL MAINTAIN BLDG COMPLIANT MANNER.NOTE:@BOILER ROOM PIT AND VARIOUS LOCS WATER PENETRATING C... | $0 | $0 | Jan 8, 2016 |
| Aug 15, 2014 | 35107198M | RESOLVE | CLASS - 2 | REISSUE 35017085R.WATER PENETRATION INTO BOILER ROOM PIT CAUING SEVEREPONDING OF WATER.REM:SEAL PENETRATION. | $0 | $0 | Oct 31, 2014 |
| May 1, 2013 | 35017088M | RESOLVE | CLASS - 3 | REISSUE - 34957766X. WATER DAMAGE/SPALLING/CRACK PLASTER WALLS AND CEILING ROOM 345 3RD STY. REMEDY: MAINTAIN BLDG AS... | $0 | $0 | Jul 19, 2013 |
| May 1, 2013 | 35017084P | RESOLVE | CLASS - 3 | REISSUE - 34957765Y. 1- ROOM 233 DOORS TILE SPLIT - HARDWARE - DEFECT.2- ROOF ACCESS GATE 4TH FL STAIR C HARDWARE DEF... | $0 | $0 | Jul 19, 2013 |
| May 1, 2013 | 35017085R | RESOLVE | CLASS - 2 | REISSUE - 34957764M. WATER PENETRATION CELLAR SLAB AND FOUNDATION WALLS AT CELLAR BOILER ROOM PIT AND PIPE CHASE ADJA... | $0 | $0 | Jul 19, 2013 |
| May 1, 2013 | 35017083N | RESOLVE | CLASS - 2 | MECHANICAL ROOM - DEFECTIVE DOOR HARDWARE DOOR KNOBS. REMEDY: PROVIDE LEGAL HARDWARE. | $0 | $0 | Jul 19, 2013 |
| May 2, 2012 | 34957766X | RESOLVE | CLASS - 3 | RE-ISSUE #34926847X WATER DAMAGED/SPALLING/CRACKED PLASTER WALLS & CEILING. AT CELLAR CAFETERIA APPROX 12SQ FEET AT 3... | $0 | $0 | Jul 20, 2012 |
| May 2, 2012 | 34957764M | RESOLVE | CLASS - 2 | RE-ISSUE #34926849J WATER PENETRATING CELLAR SLAB & FOUNDATION WALLS. AT CELLAR BOILER ROOM PIT & PIPE CHASE ADJACENT... | $0 | $0 | Jul 20, 2012 |
| May 2, 2012 | 34957765Y | RESOLVE | CLASS - 2 | DOORS NOT CLOSING AT 1ST STORY EXIT 3 VESTIBULE DOOR 2ND STORY ROOM 233 DOOR STILE SPLIT 4TH STORY CROSS CORRIDOR DOO... | $0 | $0 | Jul 20, 2012 |
| Aug 9, 2011 | 34926847X | RESOLVE | CLASS - 3 | PLASTER CRACKED/SPALLING/BULGING/DISPLACED (1) AT CELLAR CAFETERIA APPROX 12 OF CEILING DISPLACED (ONE 4 SECTION & ON... | $0 | $0 | Oct 21, 2011 |
| Aug 9, 2011 | 34926849J | RESOLVE | CLASS - 2 | REISSUE #34861856N WATER PENETRATING CELLAR SLAB & FOUNDATION WALLS. AT CELLAR BOILER PIT,& PIPE CHASE ADJACENT TO FA... | $0 | $0 | Oct 21, 2011 |
| Aug 9, 2011 | 34926848H | RESOLVE | CLASS - 2 | DOORS NOT CLOSING: AT 1ST STORY: EXIT 1 VESTIBULE DOORS (3 DOORS) DOORS WARPED RAILS SEPARATING FROM STILES. 2ND STOR... | $0 | $0 | Oct 21, 2011 |
| Jul 1, 2010 | 34861856N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN OBSERVED WATER PENETRATION INTO BOILER PIT AREA THROUGH FOUNDATION WALL AND/OR FLOOR STANDING WAT... | $0 | $0 | Sep 17, 2010 |
| Jul 1, 2010 | 34861857P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN OBSERVED FPSC DOORS WARPED AND/OR RACKED WONT PROPERLY CREATE AT BOTH AUDITORIUM FRONT EXIT 1 1FL... | $0 | $0 | Sep 17, 2010 |
| May 20, 2009 | 34765173Y | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED ACCEPTED PLANS AT JOB SITE AT TIME OF INSP NO DOT APPROVED DRAWING FOR SHED ON SITE JHS P... | $0 | $0 | Jul 10, 2009 |
| May 20, 2009 | 34765171K | RESOLVE | CLASS - 2 | FOLLOWING THE RECEIPT OF A PERMIT TO ERECT A SIDEWALK SHED THE PERMIT HOLDER SHALL POST A READILY VISIBLE SIGN ON THE... | $0 | $0 | Jul 10, 2009 |
| Mar 4, 2009 | 34761767N | RESOLVE | CLASS - 2 | REISSUE:34638553Y.PLASTER IS SPALLING ON THE WALLS & CEILING LOCATED IN ROOM 305 & 340 ON THE 3FL LEVEL,ROOMS 411,424... | $0 | $0 | May 15, 2009 |
| Mar 4, 2009 | 34761766L | RESOLVE | CLASS - 2 | REISSUE:34638549L. EXTERIOR ROOF HAS BECOME POROUS & ALLOWING RAIN WATER INTO THE BLDG CAUSING INTERIOR DAMAGES BY ST... | $0 | $0 | May 15, 2009 |
| Apr 16, 2008 | 34638555H | RESOLVE | Non-Hazardous | GLAZED BLOCK WALL HAS A HOLE APPROXIMATELY 4" WIDE NEXT TO THE FRONT OF THE GYMNASIUM 1ST FLOOR. REMEDY: REPAIR BLOCK... | $0 | $0 | Jun 13, 2008 |
| Apr 16, 2008 | 34638549L | RESOLVE | Non-Hazardous | REISSUE 34576955X EXTERIOR ROOF HAS BECOME POROUS AND ALLOWING THE RAIN WATER INTO THE BLDG CAUSING INTERIOR DAMAGES.... | $0 | $0 | Jun 13, 2008 |
| Apr 16, 2008 | 34638553Y | RESOLVE | Non-Hazardous | REISSUE 34576957J PLASTER ON THE WALLS & CEILING IS SPALLING LOCATED IN ROOM 305 & 340 ON THE 3RD FLOOR LEVEL, ROOMS ... | $0 | $0 | Jun 13, 2008 |
| Apr 16, 2008 | 34638554X | RESOLVE | Non-Hazardous | EXTERIOR CONCRETE STEP BY EXIT ( ) ON THE 1ST FLOOR LEVEL IS SINKING APPROX 3" MAKING STEPS UNEVEN. REMEDY: REPAIR CO... | $0 | $0 | Jun 13, 2008 |
| Apr 16, 2008 | 34638556J | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE PANIC HARDWARE IN PLACE OF ASSEMBLY. NOTED: CAFETERIA AT EXIT DOOR IS MISSING PANIC HARDWARE ON EX... | $0 | $0 | Jun 13, 2008 |
| Jun 27, 2007 | 34576957J | RESOLVE | Hazardous | REISSUE VI 34526928P. DEFECTIVE PLASTER SPALLING FROM CEILING & WALLS IN ROOMS 340 305 424 429 431 411 & STAIRWELL 8/... | $0 | $0 | Aug 17, 2007 |
| Jun 27, 2007 | 34576956H | RESOLVE | Hazardous | REISSUE VI #34393473L. SOUTH & NORTH FACADE HAVE DEFECTS IN LINTELS & MORTOR IS MISSING AT BRICK WORK. LOCATION 1-2 F... | $0 | $0 | Aug 17, 2007 |
| Jun 27, 2007 | 34576955X | RESOLVE | Hazardous | REISSUE VI #34393472J. WATER PENETRATION THRU ROOF LOCATION 4 FL RMS 429,424,411 3 FL RM 305. REMEDY: STOP WATER PENE... | $0 | $0 | Aug 17, 2007 |
| Jun 2, 2006 | 34393474N | RESOLVE | Non-Hazardous | REISSUE VI 34423445Z. WATER PENETRATION THROUGH WALL OF FOUNDATION ANDFLOOR LOCATION CELLAR BOILER ROOM. REMEDY:STOP ... | $0 | $0 | Aug 18, 2006 |
| Jun 2, 2006 | 34526928P | RESOLVE | Hazardous | FAILURE TO MAINTAIN PLASTER CEILING & WALL.PLASTER IS SPALLING BECAUSEOF WATER PENETRATION FROM EXTERIOR. PLASTER IS ... | $0 | $0 | Aug 18, 2006 |
| Jun 2, 2006 | 34393473L | RESOLVE | Non-Hazardous | REISSUE VI 34466346N & 34466348R. SOUTH FACADE & NORTH FACADE DEFECT LINTELS & MORTAR IS MISSING AT BRICK WORK AT LIN... | $0 | $0 | Aug 18, 2006 |
| Jun 2, 2006 | 34526929R | RESOLVE | Hazardous | FAILURE TO MAIN INTERIOR BLOCK WALL ABOVE DR IN CLASS RM'S# 28, 25, 27(HAS CRACKS IN THE WALL). REMEDY: REPAIR BLOCK ... | $0 | $0 | Aug 18, 2006 |
| Jun 2, 2006 | 34393475P | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BLOCK WALL IN GYM NEXT TO WINDOW.BLOCK BULGING OUT WHERE BACK BOARD IS ATTACHED (BASKET BALL)REME... | $0 | $0 | Aug 18, 2006 |
| Jun 2, 2006 | 34393472J | RESOLVE | Non-Hazardous | REISSUE VI # 34466344J.WATER PENETRATION THROUGH ROOF. LOCATION: 4TH FL ROOMS 429,424,411, 3RD FL ROOM 305. REMEDY:RE... | $0 | $0 | Aug 18, 2006 |
| Feb 8, 2005 | 34466344J | RESOLVE | Hazardous | REISSUE #34423447M WATER PENETRATION THROUGH ROOF LOCATIONS:4TH FL:RMS 429,424,411. 3RD FL:RM 305. REMEDY:REPAIR ALL ... | $0 | $0 | Apr 22, 2005 |
| Feb 8, 2005 | 34466348R | RESOLVE | Non-Hazardous | CRACKS IN BRICKWORK AND MORTAR MISSING AT BRICK JOINTS (MORRISON FACADE) LOCATIONS: NORTH AND SOUTH ROOF BULKHEADS: 1... | $0 | $0 | Apr 22, 2005 |
| Feb 8, 2005 | 34466346N | RESOLVE | Non-Hazardous | SOUTH FACADE. DEFECTIVE LENTELS AND MORTAR IS MISSING AT BRICK WORK ABOVE LINTELS LOCATION: SOUTH FACADE FLOORS 2,3. ... | $0 | $0 | Apr 22, 2005 |
| Feb 8, 2005 | 34466345L | RESOLVE | Non-Hazardous | MISSING SMOKE DOOR IN CORRIDOR LOCARION: 4TH FLOOR OUTSIDE OF ROOM 424. REMEDY:REPLACE MISSING DOOR. | $0 | $0 | Apr 22, 2005 |
| Feb 8, 2005 | 34466347P | RESOLVE | Non-Hazardous | MISSING PANIC BARS ON DOORS AT: REISSUE #34423446K LOCATION: 1ST FLOORGYM P.A. OCCUPANCY, 383 PERSONS 1) DOOR: BASEME... | $0 | $0 | Apr 22, 2005 |
| Jan 30, 2004 | 34423445Z | RESOLVE | Non-Hazardous | REISSUE:FAILURE TO MAINTAIN:DEFECT NOTED:WATER PENETRATION THRU WALL AND FOUNDATION FLOOR.LOCATION:BASEMENT,REMEDY:MA... | $0 | $0 | Mar 26, 2004 |
| Jan 30, 2004 | 34423447M | RESOLVE | Non-Hazardous | RESIUSSE:FAILURE TO MAINTAIN:DEFECT NOTED:WATER PENERATIONS HRU ROOF EFFECTING INTERIOR.LOCATION:4TH FLOOR OVER ROOMS... | $0 | $0 | Mar 26, 2004 |
| Jan 30, 2004 | 34423446K | RESOLVE | Non-Hazardous | REISSUE:FAILURE TO USE PANIC HARDWARE WHERE REQUIRED BY LAW.LOCATION CAFETERIA:REAR DOOR #2 OCCUPANCY 350.REMEDY:PROV... | $0 | $0 | Mar 26, 2004 |
| Dec 23, 2003 | 38143547Z | RESOLVE | Non-Hazardous | 83##. 83-MAKE ALL REPAIRS TO LIFT CEASE USE ON 3-15-02 AND CALL THIS DEPT FOR INSPECTION 212-566-5543 | $0 | $0 | Feb 6, 2004 |
| Dec 23, 2003 | 38143546R | RESOLVE | Non-Hazardous | 83X#.MAKE ALL REPAIRS TO LIFT CEASE USE ON 3/11/02 AND CALL THIS DEPT FOR A INSPECTION 212-566-5543 | $0 | $0 | Feb 6, 2004 |
| Mar 5, 2003 | 34385694P | RESOLVE | Non-Hazardous | FAILURE TO USE PANCI HAND WERE WHERE REQUIRED BY LAW LOCATION CAFETERIA OCCUPANCY 560 GYPSMASIUM 350 REMEDY: PROVIDE ... | $0 | $0 | Jul 18, 2003 |
| Mar 5, 2003 | 34385695R | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR DEFECT STEEL WIMDOW LENTILS ROTTED SPLITTING CAUSING MORTAR BRICKS TO BECOME LOOSE ALLOW... | $0 | $0 | Jul 18, 2003 |
| Mar 5, 2003 | 34385696Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DEFECT WATER PENETRATION FROM EXTERIOR WALLS CAUSING PLASTER TO SPALL BLDG LOCATION STAIRWAY 4 RM... | $2,500 | $0 | Jul 18, 2003 |
| Mar 5, 2003 | 34385693N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN DEFECT WATER PEMETRATION FROM WALLS FL CLAUSING CONCRETE FOUNDATION TO SPALL ERODE LOCATION ENTIR... | $0 | $0 | Jul 18, 2003 |