ECB violations
1151 Elder Avenue, Bronx • Block 03739 • Lot 0055
37 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Dec 30, 2025 | 39171934N | RESOLVE | CLASS - 2 | OBSERVED AT BUILDING FRONT EXTERIOR A FEW AC UNITS IS INSTALLED AT FIRE ESCAPE WINDOW OPENINGS PLUS OTHER WINDOW AC U... | $0 | $0 | Jul 17, 2026 |
| Oct 1, 2019 | 39010427L | ACTIVE | CLASS - 2 | FOUND EXPOSED WIRING, SMOKE ALARM AT FLUE PIPE DEFECTIVE =, REPAIR OR REPLACE. BODY DRAIN ON SAFETY RELIEF VALVE MISS... | $312 | $0 | Jul 24, 2020 |
| Jun 3, 2018 | 35338792N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION# 35331935J ISSUED ON 5/18/18 & TO FILE A... | $1,250 | $0 | Sep 28, 2018 |
| May 18, 2018 | 35331936L | ACTIVE | CLASS - 1 | FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.OBSERVED IN CELLAR SEVERAL LOCATIONS GAS PLUMBING WORK DONE.DOB... | $2,500 | $0 | Sep 14, 2018 |
| May 18, 2018 | 35331935J | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT.OBSERVED IN SEVERAL LOCATION SIN CELLAR GAS PLUMBING WORK DONE.DOB RECORDS DOES NOT SHOW ANY RE... | $1,600 | $0 | Sep 14, 2018 |
| Feb 18, 2018 | 35317528L | RESOLVE | CLASS - 1 | REISSUED ECB #35297447Y FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGE WAY NOTE: EMERGENCY FIRE ESCAPE EXIT PASSAGEWAY ... | $1,000 | $0 | Apr 20, 2018 |
| Dec 26, 2017 | 35297494R | RESOLVE | CLASS - 2 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,DEVICES,MATERIALS,APPLIANCES OR WIRING IN USE. OBSERVED I... | $400 | $0 | May 14, 2018 |
| Dec 26, 2017 | 35297447Y | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:OBSERVED EMERGENCY FIRE ESCAPES EXIT PASSAGEWAY OBSTRUCTED BY E... | $1,000 | $0 | Feb 16, 2018 |
| Aug 14, 2017 | 35284786X | RESOLVE | CLASS - 2 | UNLAWFUL ACTS. FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER. IN 6-15-17 A ELECTRICAL VIOLATION WAS ISSUE TO THE R... | $800 | $0 | Nov 8, 2017 |
| Aug 5, 2017 | 35276175R | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUM/VIO#35270673M ISSUED ON 06/15/17 & TO FILE A C OF C PURSUANT TO... | $800 | $0 | Nov 3, 2017 |
| Jun 15, 2017 | 35271237K | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. OBSERVED MC CABLES INSTALLED IN BASEMENTBOILER ROOM TO VARIOUS PAINTS ALONG WALL LEADIN... | $800 | $0 | Aug 25, 2017 |
| Jun 15, 2017 | 35271238M | RESOLVE | CLASS - 1 | FAILURE TO GROUND ELECTRICAL SYSTEMS. OBSERVED BROKEN CONDUIT NOT CONNECTED TO WATER SERVICE ENTRNACE PIPE. NO WATER ... | $4,800 | $0 | Aug 25, 2017 |
| Jun 15, 2017 | 35270672K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED:5TH FLR BYSTAIRS GOING TO THE ROOF SECTION OF THE CEILING... | $250 | $0 | Aug 18, 2017 |
| Jun 15, 2017 | 35270673M | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:AT EXP 1 ELDER AVE SIDE 5TH FLR FIRE ESCAPE USED AS STORAGE PLA... | $250 | $0 | Aug 25, 2017 |
| Jun 15, 2017 | 35271426J | ACTIVE | CLASS - 2 | SEC. 408.2 FUTURE CONNECTIONS EXITS DOWN STREAM OF APPLIANCE. OBSERVED ON 6/15/17 IN BASEMENT. AT ABOVE ADDRESS,FUTUR... | $800 | $0 | Aug 25, 2017 |
| Jun 15, 2017 | 35271427L | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED ON 6/15/17 IN BASEMENT AT ABOVE ADDRESS FERNCO COUPLIN... | $500 | $0 | Aug 25, 2017 |
| Jan 19, 2017 | 35229712L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN A BLDG IN CODE COMPLIANT MANNER. FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMO... | $400 | $0 | Mar 17, 2017 |
| Nov 23, 2016 | 35221505M | RESOLVE | CLASS - 1 | SEC. 408.2 MISC VIOLATION: FUTURE CONNECTIONS EXIST ON GAS PIPING. AT THE TIME OF MY INSPECTION 12:05PM ON 11-23-16 A... | $0 | $0 | Mar 3, 2017 |
| Nov 23, 2016 | 35221506Y | RESOLVE | CLASS - 2 | FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. RE: INSTALLATION MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER PC 1... | $500 | $0 | Mar 3, 2017 |
| Nov 23, 2016 | 35221507X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT THE TIME OF MY INSPECTION 12:05PM ON 11-23-16 AT THE ABOVE PLAE... | $1,000 | $0 | Mar 3, 2017 |
| Nov 23, 2016 | 35221542L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. FLOOR NUMBERING SIGNS MISSING &/OR DEFECTIVE PER BC1019.1.7;27-392... | $250 | $0 | Mar 3, 2017 |
| Nov 15, 2011 | 34912820Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER OBSERVED AT LOCATION SEWER WATER LEAKING OUT ONTO ADJACENT PROP... | $1,250 | $0 | Dec 30, 2011 |
| Nov 15, 2011 | 34912819L | RESOLVE | CLASS - 2 | WORK W/O A PERMIT OBSERVED AT TIME OF INSPECTION 3" WASTE STACK CUT & RE-ROUTED AROUND 30' OF 3" CAST IRON PIPING TO ... | $800 | $0 | Dec 30, 2011 |
| Oct 12, 2011 | 32071364H | ACTIVE | CLASS - 2 | 15 21B 34A 42 50AB 50A-DEFECTIVE DRAFT REGULATOR 50B-IMPROPER SUSPENSION OF BOILER PLUMBING W/ BANDED IRON AND CABLES... | $500 | $0 | Dec 2, 2011 |
| Mar 7, 2011 | 34869168X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER FOUND IN REAR OF LOCATION SEWAGE WATER RUNNING ONTO ADJACENT PROP... | $500 | $0 | Aug 5, 2011 |
| Nov 9, 2010 | 34883427M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES. NOTED: EXTERIOR BRICK CHIMNEY AT ROOF LEVEL IS CRACKED W/AN 1/2" W... | $1,000 | $0 | Feb 18, 2011 |
| Sep 29, 2010 | 34878076N | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: BRICK CHIMNEY,APPROX 6FT HIGH,HAS SEMI-VERTICAL CRACKS APPROX... | $1,000 | $0 | Jan 28, 2011 |
| Jul 27, 2010 | 34863936M | ACTIVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER TO FILE A C/C W/THE DOB. NOTED: RESPONDENT FAILED TO COMPLY W/THE COMMISSIONER'S... | $800 | $0 | Oct 15, 2010 |
| Jul 22, 2010 | 34851388M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER: NOTED: EXCESSIVE ACCUMULATIONS OF LOOSE CONSTRUCTION DEBRIS (C... | $1,000 | $0 | Sep 17, 2010 |
| Jul 21, 2010 | 34863915N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMM'S ORDER TO FILE A CERT OF CORRECTION WW/THE DEPT OF BLDGS.NOTED:RESPONDENT FAILUED TO... | $0 | $0 | Sep 17, 2010 |
| Jul 21, 2010 | 34863914L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES NOTED BRICK CHIMNEY APPX 6FT HIGH HAS SEMI VERTICAL CRACK APPRX 3/8" ... | $0 | $0 | Sep 17, 2010 |
| Feb 3, 2010 | 34812334P | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER DEFECT NOTED @ ROOF LEVEL TOP SECTION OF BRICK CHIMNEY DEFECTIVE W/... | $5,000 | $0 | Apr 2, 2010 |
| Aug 31, 2009 | 34786749K | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN BUILDING INTERIOR. DEFECTS NOTED: PARTIAL COLLAPSE OF BATHROOM CEILING DUE TO WATER LEAKS AT APT ... | $500 | $0 | Oct 30, 2009 |
| Sep 12, 2008 | 32060435M | ACTIVE | CLASS - 3 | 16,24B,32A,34A,40,42,50,50A,50B,50C. 24B MISSING SHUT OFF SWITCH ON 2ND BOILER ROOM DOOR. 50 AIR GAP & DISCHARGE PIPE... | $200 | $0 | Jan 9, 2009 |
| Jun 30, 2008 | 32056667J | ACTIVE | Non-Hazardous | B4A, 34A, 34B, 40, 24B, 32A, 42, 50, 50A, 50B, 50C, 50D, 50E, 50F 50 BOTH BOILER RM DOORS NOT SELF CLOSING 50A NEED S... | $2,500 | $0 | Aug 29, 2008 |
| Jun 19, 2008 | 34632290Y | ACTIVE | Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O OR BLDG DEPT RECORDS. CELLARCONVERTED FROM ORDINARY USE INTO B-ROOM A TOTAL... | $800 | $0 | Aug 28, 2009 |
| May 7, 2007 | 32053832K | ACTIVE | Non-Hazardous | B4A,32A,32B,45A,45B,50A,50B,50C,50D,50E,48A. 50A COVER MISSING ON CONTROL 50B REAR SIGHT GLASS BROKEN/DEFECTIVE 50C F... | $350 | $0 | Jul 13, 2007 |