ECB violations
1161-1163 Stratford Avenue, Bronx • Block 03743 • Lot 0057
26 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 12, 2021 | 35530329L | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V39018310Y ISSUED2/25/20 &TO FILE C/C PURSUANT TO28-201... | $0 | $0 | Oct 8, 2021 |
| Mar 16, 2021 | 35526587M | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS.VIOLATION#39018310Y ISSUED ON 02-25-20 AND TO FIL... | $0 | $0 | Oct 15, 2021 |
| Jan 15, 2021 | 35524678Z | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/ COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39018310Y ISSUED ON 2/25/20 & TO FILE CERTIF... | $0 | $0 | Oct 28, 2021 |
| Oct 6, 2020 | 35520322J | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39018310Y ISSUED ON 02/25/20 & TO FILE A CERT OF CORREC... | $0 | $0 | Oct 28, 2021 |
| Feb 25, 2020 | 39018313J | RESOLVE | CLASS - 1 | HPD REG#201458 INDICATES 5 STORY/70 DWELLINGS, 5 LEGAL APTS IN THE BASEMENT. OBSERVED IN THE BASEMENT UNDER 1161 STRA... | $16,000 | $0 | Oct 8, 2021 |
| Feb 25, 2020 | 39018310Y | RESOLVE | CLASS - 1 | OBSERVED IN BASEMENT ADDITIONAL PARTITIONS TO CREATE HALLWAYS AND ROOMS FOR 4 INDIVIDUAL SRO'S. UNPERMITTED PLUMBING ... | $0 | $0 | Oct 8, 2021 |
| Feb 25, 2020 | 39018312H | RESOLVE | CLASS - 1 | HPD REG#201458 INDICATES 5 STORY/70 DWELLINGS, 5 LEGAL APTS IN THE BASEMENT. OBSERVED IN THE BASEMENT UNDER 1163 STRA... | $16,000 | $0 | Oct 8, 2021 |
| Feb 25, 2020 | 39018311X | RESOLVE | CLASS - 1 | NO FIRE STOPPING PER BC 712.3; 27-345. OBSERVED IN THE BASEMENT AT MANY AREAS WITH INADEQUATE FIRESTOPPING AT THE SLA... | $1,250 | $0 | Oct 8, 2021 |
| Feb 25, 2020 | 39018315N | RESOLVE | CLASS - 1 | HPD REG#201458 INDICATES 5 STORY/70 DWELLINGS, 5 LEGAL APTS IN THE BASEMENT. OBSERVED IN THE BASEMENT UNDER 1163 STRA... | $16,000 | $0 | Oct 8, 2021 |
| Feb 25, 2020 | 39018314L | RESOLVE | CLASS - 1 | HPD REG#201458 INDICATES 5 STORY/70 DWELLINGS, 5 LEGAL APTS IN THE BASEMENT. OBSERVED IN THE BASEMENT UNDER 1161 STRA... | $16,000 | $0 | Oct 8, 2021 |
| Feb 25, 2020 | 39018309R | RESOLVE | CLASS - 1 | I OBSERVED THROUGH-OUT THE BASEMENT, ELECTRICAL BOXES THAT ARE OPEN, ARMORED CABLE SPLICED TOGETHER WITHOUT AN ELECTR... | $1,600 | $0 | May 14, 2021 |
| Apr 2, 2018 | 32093093M | RESOLVE | CLASS - 2 | 50A,50B,50C-50A)COMBUSTIBLE MATERIAL IN BOILER ROOM. 50B)GUARD FOR THE GAUGE GLASS IS MISSING. 50C)DOG TAG MISSING A ... | $0 | $0 | Aug 10, 2018 |
| Dec 26, 2017 | 35311106Y | RESOLVE | CLASS - 1 | MISC VIOLATIONS: GAS PIPING NOT LABELED. OBSERVED IN CELLAR PASSAGE WAY GAS PIPING NOT LABELED CORRECTLY TO INDICATE ... | $1,000 | $0 | Mar 14, 2018 |
| Nov 8, 2017 | 35279016N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35287265Y ISSUED ON 06/13/17 & TO FILE A C OF C PURSUAN... | $0 | $0 | Apr 27, 2018 |
| Sep 21, 2017 | 35277218M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUM/VIO#35287265Y ISSUED ON 06/13/17 & TO FILE A C OF C PURSUANT TO... | $2,000 | $0 | Nov 17, 2017 |
| Jun 13, 2017 | 35287265Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN CELLAR EXCESSIVE STORAGE IN GAS METERS AREA: REF: FGC ... | $1,000 | $0 | Jan 19, 2018 |
| Jun 13, 2017 | 35268024J | RESOLVE | CLASS - 1 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE. OBSERVED O... | $1,600 | $0 | Aug 7, 2017 |
| Jun 13, 2017 | 35271250P | RESOLVE | CLASS - 1 | FAILURE TO GROUND ELECTRICAL SYSTEMS. OBSERVED IN BASEMENT: MAIN GROUNDING CONDUCTOR FOR BLDGS ELECTRICAL SYSTEMS DIS... | $4,800 | $0 | Aug 4, 2017 |
| Jun 13, 2017 | 35272345M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3;27-345. NOTED: OBSERVED THROUGHOUT C... | $250 | $0 | Jan 19, 2018 |
| Jun 13, 2017 | 35272346Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: STAIRWELL WINDOW ON LANDING OF 2ND & 3RD FL IS BROKEN & SHA... | $250 | $0 | Jan 19, 2018 |
| Jun 13, 2017 | 35287264M | RESOLVE | CLASS - 1 | SEC. MISC VIOLATIONS: GAS PIPING NOT LABELED. OBSERVED IN CELLAR GAS PIPING NOT LABELED THROUGHPUT HALLWAY TO INDICAT... | $400 | $0 | Jan 19, 2018 |
| Dec 20, 2016 | 35222287H | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE UNBSTRUCTED EXIT PASSAGEWAY. NOTED: EXP#1 FIRE ESCAPES EXP#2 FIRE ESCAPE & AT MAIN ENTRANCES OF 2 ... | $250 | $0 | Feb 3, 2017 |
| Feb 17, 2016 | 35170957X | ACTIVE | CLASS - 3 | WORK W/O A PERMIT. WORK NOTED: ERECTED A FULL HEIGHT PARTITION IN THE LIVING ROOM W/DOOR & LOCKING DEVICE. NOTE WALL ... | $200 | $0 | Jul 15, 2016 |
| Jun 18, 2003 | 34396939H | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. WORK NOTED: (1)HAVING REMOVED APPROXITMATLY 20 LINNER FEET OF COPING STONE AT FRONT OF BUILDIN... | $250 | $0 | Aug 1, 2003 |
| Apr 19, 2003 | 34342513R | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. REMOVING AND REPLACING BRICK PARAPET OVER ENTRANCE TO 1163 STRATFORD AT INNER COURT YARD WITHO... | $800 | $0 | Jun 6, 2003 |
| Dec 12, 2001 | 34306201J | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING DEFECT IS: SPALLING AND DEFECTIVE CONCRETE AND STEPS AT ENTRANCE COURT YARD OF BUILDING.... | $0 | $0 | Jan 25, 2002 |