ECB violations
1200-1230 Croes Avenue, Bronx • Block 03749 • Lot 0001
105 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 29, 2020 | 37019510K | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35444861R ISSUED ON 12/05/19,AND TO FILE ... | $1,250 | $0 | Oct 2, 2020 |
| Dec 5, 2019 | 35444861R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. AS NOTED EXPOSURE 1 SPALLED BRICK,VERTICAL CRACKING,D... | $2,500 | $0 | Jan 31, 2020 |
| Nov 13, 2019 | 37015800K | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#32097843K ISSUED ON 01-23-19 & TO FILE A C OF C PURSUAN... | $1,250 | $0 | Jan 17, 2020 |
| Nov 13, 2019 | 37015801M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#32097844M ISSUED ON 01-23-19 & TO FILE A C OF C PURSUAN... | $1,250 | $0 | Jan 17, 2020 |
| Oct 16, 2019 | 38265438P | RESOLVE | CLASS - 1 | 97X17-ENTIRE DEVICE INOPERATIVE,ON A 21 STORY BUILDING WITH ONLY ONE ELEVATOR AS AN ALTERNATE SERVICE MUST REPAIR DEV... | $1,250 | $0 | Dec 6, 2019 |
| Aug 28, 2019 | 38268014P | RESOLVE | CLASS - 2 | 74H10-CANT GUIDE ROLLERS,WORN,REPAIR | $0 | $0 | Oct 18, 2019 |
| May 28, 2019 | 38269927Y | RESOLVE | CLASS - 1 | RTS 97X10, 56Y13,61T07. 97X10-RESTORED TO SERVICE, AN ELEVATOR IN A 21 STORIED BUILDING IS OUT OF SERVICE CREATING A ... | $3,125 | $0 | Jul 19, 2019 |
| Apr 6, 2019 | 38267274R | RESOLVE | CLASS - 2 | 10H11,79B14; 79.COMP CHAIN RUBBING PIT STEEL. | $0 | $0 | May 31, 2019 |
| Jan 23, 2019 | 32097844M | RESOLVE | CLASS - 2 | B254,18A,32A,50A,50B,50C,50D. GIBRATOR. BOILER MDL #GHF-322-23; 50A-VACUUM TNK LEAKING STEAM AND WATER; 50B-CONDENSAT... | $625 | $0 | Mar 15, 2019 |
| Jan 23, 2019 | 32097843K | ACTIVE | CLASS - 2 | B254,16,32A,50A,50B,50C. FEDERAL BOILER MDL FST 350: 50A-VACUUM TANK LEAKING STEAM AND WATER; 50B-CONDENSATION TANK L... | $625 | $0 | Mar 15, 2019 |
| Aug 26, 2018 | 38264746M | RESOLVE | CLASS - 2 | 05-J-10,42-B-11,42-G-11,59-M-07,41-M-07.(05-J-10)=REMEDY REPAIR GAP IN CAR DOOR (42-B-11)=REMEDY REPLACE OR REPAIR DO... | $0 | $0 | Oct 19, 2018 |
| Aug 1, 2018 | 38263593X | RESOLVE | CLASS - 1 | CU59N10 BRAKE SWITCH IS BYPASSED,REPAIR. | $1,250 | $0 | Sep 21, 2018 |
| May 22, 2018 | 38262243L | RESOLVE | CLASS - 1 | 97X10 UPON INSPECTION ELEVATOR OUT OF SERVICE CREATING A HAZARDOUS CONDITION AS PER 1RCNY 11-02 BUILDING CODE. RESTOR... | $625 | $0 | Oct 19, 2018 |
| May 17, 2017 | 38253649R | RESOLVE | CLASS - 2 | 97X17 UPON INSPECTION ELEVATOR WAS FOUND TO BE OUT OF SERVICE CREATING A HAZARDOUS CONDITION ASPER 1RCNY 11-02. BUILD... | $500 | $0 | Jul 7, 2017 |
| Apr 11, 2017 | 38254360K | RESOLVE | CLASS - 2 | 42G11 DUMP FUSE IN CONTROLLER NEEDS TO BE REPLACED. | $250 | $0 | Oct 27, 2017 |
| May 16, 2016 | 38242910H | RESOLVE | CLASS - 2 | 59U15 - 1 YEAR BRAKE TEST TAG IS MISSING (PROVIDE) | $0 | $0 | Jul 1, 2016 |
| May 16, 2016 | 38242909K | RESOLVE | CLASS - 2 | 05J10,59U15 | $250 | $0 | Jul 1, 2016 |
| Feb 19, 2016 | 35133961X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES. NOTED (I) AT EXP1-SPALLED BRICK WORK BETW 1/F WINDOWS AT SOUTH ... | $500 | $0 | Apr 15, 2016 |
| Jun 2, 2015 | 38236223P | RESOLVE | CLASS - 2 | 21Q03,21L10,29Q03,39O02,45Q11,50Q03,50Q11,60Q03,72I10,100L10. 21Q03- INSTALL COVER FOR INTERLOCK 10TH FLR; 21L10-REPA... | $0 | $0 | Jul 17, 2015 |
| Jan 7, 2015 | 35101873J | RESOLVE | CLASS - 3 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENT. NOTED: JOB #240073120(SIGNED OFF)& P... | $200 | $0 | Mar 6, 2015 |
| Jul 1, 2014 | 38232051J | RESOLVE | CLASS - 2 | 39O02,39Q03,50Q03,56Y13,60Q03,73O03,74O02,97O02.39Q03 INSTALL GUARD FOR LIGHT TOP OF CAR.50Q03 INSTALL COVER FOR GENE... | $500 | $0 | Sep 19, 2014 |
| Jan 13, 2014 | 38229506J | RESOLVE | CLASS - 2 | 97X10 - DEVICE OUT OF SERVICE. 2 DEVICES IN THE BUILDING ONLY 1 IS WORKING, 21 FLOORS BUILDING. REPAIR AND RESTORE TO... | $250 | $0 | Mar 7, 2014 |
| Feb 21, 2013 | 35010924R | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES. NOTED: AT ROOF LEVEL AT SOUTH EAST SIDE,ALUMINUM FLASHING APPROX 7'IN... | $0 | $0 | Apr 19, 2013 |
| Dec 11, 2012 | 32072810N | RESOLVE | CLASS - 2 | B254,50ABC. 50A-SOOT ON BOILER;50B-LEAK ON CONDENSATE PUMP;50C-LADDER AND PLATFORM, REQUIRED FOR BOILER. | $530 | $0 | Feb 1, 2013 |
| Dec 11, 2012 | 32072811P | RESOLVE | CLASS - 2 | B254,50ABC. 50A-SOOT ON BOILER; 50B-LEAK ON CONDENSATE PUMP; 50C-LADDER AND PLATFORM REQUIRED FOR BOILER. | $530 | $0 | Feb 1, 2013 |
| Jul 31, 2012 | 38222719L | RESOLVE | CLASS - 2 | 15I11,29Q03,42M11,50Q03,56Y13,60Q03,61T07,67M07,71Q03,39X10,77Q03: 42Q03;INSTALL COVER FOR RESISTORS ON TOP OF CONTRO... | $500 | $0 | Sep 21, 2012 |
| Jul 25, 2012 | 34937333M | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. A TRENCH OF APPROX 20'L X 5'W X 2 1... | $0 | -$69 | Sep 21, 2012 |
| Mar 26, 2012 | 38221251K | RESOLVE | CLASS - 1 | 97X10. 97:ONE OF TWO ELEVATORS IN BLDG IS OUT-OF-SERVICE (21 STORIES). RESTORE TO SERVICE. | $1,000 | $0 | May 18, 2012 |
| Mar 21, 2012 | 38220548R | RESOLVE | CLASS - 1 | 97X10:REPAIRE IMMEDIATELY ONE OF TWO ELEVATORS OUT OF SERVICE IN 21 STORY BUILDING THERE BY CAUSING HAZARDOUS CONDITI... | $1,000 | $0 | May 18, 2012 |
| Feb 28, 2012 | 38219356Y | RESOLVE | CLASS - 2 | 28-304.7 100R7 THE OWNER SHALL HAVE A MAINTAINANCE CONTRACT W/ AN APPROVED AGENCY TO PERFORM ELEVATOR REPAIR WORK AND... | $0 | $0 | Apr 20, 2012 |
| Dec 25, 2011 | 38219352R | RESOLVE | CLASS - 2 | 56Y10,59H11. 59H- WORN MACHINE BRAKES, REPLACE AND PROPERTY ADJUST. | $500 | $0 | Jun 1, 2012 |
| Dec 25, 2011 | 38219351P | RESOLVE | CLASS - 1 | 97X10,56X10. 97X- ENTIRE ELEV OUT OF SERVICE. 21 FLR BLDG ONLY 1 ELEVATOR IN SERVICE. | $1,000 | $0 | Jun 1, 2012 |
| Apr 29, 2011 | 34890017P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN. NOTED: AT REAR COURTYARD/PARKING LOT. ALUMINUM BUMPER GUARD & CHAIN LINK FENCE ARE ( ) 45% ANGLE... | $1,000 | $0 | Jun 17, 2011 |
| Jan 20, 2011 | 38214337X | RESOLVE | CLASS - 2 | 444H08 44H11 52H11 42G11 45Q03 10MT 56O2 50Q3 81M7 72M07 70O02 10-PROVIDE FIRE BRACKET PER CODE 81-PER CODE 72-PER CODE | $500 | $0 | Jun 17, 2011 |
| Jan 20, 2011 | 38214338H | RESOLVE | CLASS - 2 | 42O02 50Q3 10M07 81T15 72M07 10-FIRE GIB PER CODE | $500 | $0 | Jun 20, 2011 |
| May 25, 2010 | 38209608M | RESOLVE | CLASS - 2 | 52K11 | $250 | $0 | Jul 16, 2010 |
| Jul 7, 2009 | 38203439N | RESOLVE | CLASS - 2 | 97X10,45Q03,68M07,69M07,40O02,52K11. 97-RESTORE TO SERVICE SO FULL INSPECTION CAN BE MADE BY THIS DEPT. | $500 | $0 | Apr 23, 2010 |
| Jun 26, 2009 | 38203435X | RESOLVE | CLASS - 2 | 97B10 68M7 69M07 97-ELEVATOR OUT OF SERVICE REPAIR ELEVATOR SO A FULL INP CAN BE DONE BY THE DEPT | $0 | $0 | Aug 21, 2009 |
| May 13, 2009 | 38203379K | RESOLVE | CLASS - 2 | 15I11,10H11,39O02,39Q03,41T07,52M07,60Q03,68M07,69M07,71Q03,77X10,77Q03,100X10, 39-INSTALL GUARD FOR LIGHT TOP OF CAR... | $0 | $0 | Jul 10, 2009 |
| Jul 15, 2005 | 34465650N | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED FOUND 5 COMMERCIAL DRYER WITH NO SPRINKLER COVERAG... | $400 | $0 | Mar 17, 2006 |
| Jul 15, 2005 | 34478076K | RESOLVE | Non-Hazardous | USE OR INSTALLATION OF PLUMBING MATERIALS OR EQUIPMENT WHICH DO NOT COMPLY WITH RS-16 FOUND IN LAUNDRY ROOM 5 COMMERC... | $400 | $0 | Mar 17, 2006 |
| Oct 29, 2004 | 38149956R | RESOLVE | Non-Hazardous | 85BB5/44Q3/55Y13/32O2/33O2/38O2/66O2/67O2/68O2/60T15 44- COVER AND CLEAN 60 COMPANY NAME. | $180 | $0 | Dec 17, 2004 |
| Oct 29, 2004 | 38149955P | RESOLVE | Non-Hazardous | 85BB5/44O2/55Y13/32O2/33O2/38O2/66O2/67O2/68O2/60T15 60 COMPANY NAME. | $2,500 | $0 | Feb 18, 2005 |
| Oct 28, 2002 | 38134143H | RESOLVE | Non-Hazardous | 52O02-52Y14-36O02-17H12-42O02-04P17 17 - LOBBY. | $0 | $0 | Dec 20, 2002 |
| Oct 28, 2002 | 38134142X | RESOLVE | Non-Hazardous | 81U16-52O0252Y14-42O02-36O02-17H12-05H12-04P17 17 - LOBBY 05H12 - ROLLERS. | $0 | $0 | Dec 20, 2002 |
| Jul 1, 1999 | 38088304P | RESOLVE | Non-Hazardous | 46A 50D 60M 60 M 07 PROVIDE BUFFER CTW SIDE | $0 | $0 | Aug 27, 1999 |
| Jul 1, 1999 | 38088305R | RESOLVE | Non-Hazardous | 46A 50O 60M 60 M 07 PROVIDE BUFFER CTW SIDE | $0 | $0 | Aug 27, 1999 |
| Sep 13, 1997 | 38061568Z | RESOLVE | Non-Hazardous | 73U16,44Q3,46T7,31Q3,57O2,57Z2,14M7,3O2,5J11. 31-THROUGHOUT. 14-NO CERTIFICATE IN CAR. 3-CAR TOP DIRTY. | $200 | $0 | Apr 24, 1998 |
| Sep 13, 1997 | 38061567R | RESOLVE | Non-Hazardous | 36#7,53B7,44Q3,50-1U7,50Y11,31Q3,46K11,50-2M7,57O2,57Z2,3O2,5J11. 36-PROVIDE DOOR AS PER CODE. 53-PROVIDE LIGHT SWITC... | $200 | $0 | Apr 24, 1998 |
| Sep 8, 1997 | 38062990Z | RESOLVE | Non-Hazardous | 73U40M44M50O | $0 | $0 | Dec 12, 1997 |