Oct 4, 2021 A NOV SENT OUT § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BUILDING ENTRANCE TO APT. LOCATED AT APT 3, 3rd STORY, 1st... 3 Jan 7, 2022
Oct 4, 2021 C NOTICE OF ISSUANCE SENT TO TENANT HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM WE... 3 Oct 30, 2021
Sep 28, 2021 B NOV SENT OUT § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL AT PU... Nov 2, 2021
Sep 28, 2021 B NOV SENT OUT § 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT ALL ST... Nov 2, 2021
Sep 28, 2021 C VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE THE WOOD FLOOR AT PUBLIC HALL, 1st S... Oct 4, 2021
Mar 11, 2020 B FIRST NO ACCESS TO RE- INSPECT VIOLATION § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 2 SQ FTAT CEILLING IN THE... 2NDFLO Apr 15, 2020
Nov 12, 2019 A VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 2 SQ FTAT CEILLING IN THE... 2NDFLO Feb 15, 2020
Nov 12, 2019 C NOV SENT OUT § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDS MAXIMUM ALLOEABLE TEMP OF 130 DEG... 2NDFLO Nov 20, 2019
Nov 12, 2019 A NOV SENT OUT § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILLING IN THE 1st BATHR... 2NDFLO Feb 15, 2020
Nov 12, 2019 B NOV SENT OUT § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE LOCATED AT APT 2NDFLO, 2nd STO... 2NDFLO Dec 17, 2019
Nov 12, 2019 B NOV SENT OUT § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FR... 2NDFLO Dec 17, 2019
Nov 12, 2019 C VIOLATION CLOSED § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... 2NDFLO Dec 10, 2019
I VIOLATION DISMISSED §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
Oct 21, 2019 A NOV SENT OUT § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR... Jan 24, 2020
Oct 21, 2019 A NOV SENT OUT § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... Jan 24, 2020
Oct 21, 2019 A NOV SENT OUT § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR... Jan 24, 2020
Oct 21, 2019 A NOV SENT OUT § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... Jan 24, 2020
Oct 21, 2019 C VIOLATION CLOSED § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... 2 Nov 18, 2019
Oct 21, 2019 B NOV SENT OUT § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STOR... 2 Nov 25, 2019
Oct 21, 2019 B NOV SENT OUT § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE IN THE ENTIRE APARTMENT LOCATE... 2 Nov 25, 2019
Oct 21, 2019 A NOV SENT OUT § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED... Jan 24, 2020
Oct 21, 2019 C NOV SENT OUT § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... Oct 29, 2019
Oct 21, 2019 A NOV SENT OUT § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... Jan 24, 2020
Nov 13, 2018 B NOV SENT OUT § 27-2050 ADM CODE PROVIDE A PIECE OF GARDEN HOSE 10 FEET IN LENGTH WITH FEMALE COUPLING AND A 10 QUART PAIL ON PREMI... Dec 18, 2018
I VIOLATION DISMISSED §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
I VIOLATION DISMISSED §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
Nov 9, 2017 B NOV SENT OUT § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... Dec 14, 2017
Nov 9, 2017 A NOV SENT OUT § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE PRIVATE H... 1 Feb 12, 2018
Nov 9, 2017 B NOV SENT OUT § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALL... 1 Dec 14, 2017
Nov 9, 2017 A NOV SENT OUT § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE BATHROOM ... 1 Feb 12, 2018
Nov 9, 2017 B NOV SENT OUT § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st... 1 Dec 14, 2017
Nov 9, 2017 B NOV SENT OUT § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... 1 Dec 14, 2017
Nov 9, 2017 C NOV SENT OUT § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1... 1 Nov 8, 2017
Oct 31, 2017 A NOV SENT OUT § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET SAFETY COVER/CAP AT SOUTH WALL. AT PUBLIC HALL, 1st... Feb 3, 2018
Oct 31, 2017 C NOV SENT OUT § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... Nov 8, 2017
Oct 31, 2017 A NOV SENT OUT § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED... Feb 3, 2018
Oct 31, 2017 A NOV SENT OUT § 27-2098 ADM CODE FILE WITH THIS DEPARTMENT A REGISTRATION STATEMENT FOR BUILDING. AT PUBLIC HALL, 1st STORY Feb 3, 2018
Oct 31, 2017 A NOV SENT OUT § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR... Feb 3, 2018
Oct 31, 2017 A NOV SENT OUT § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... Feb 3, 2018
Oct 31, 2017 A NOV SENT OUT § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... Feb 3, 2018
Oct 31, 2017 A NOV SENT OUT § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... Feb 3, 2018
Dec 19, 2016 B NOV SENT OUT § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING FRESH AIR INTAKE AT BOILER ROOM IN THE ENTIRE APARTMENT LOCATED AT AP... 3 Jan 23, 2017
Dec 19, 2016 B NOV SENT OUT § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY, ... 3 Jan 23, 2017
Dec 19, 2016 B NOV SENT OUT § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN, EASTNORTH -3 IN THE BATHROOM LOCATED AT A... 3 Jan 23, 2017
Dec 19, 2016 C VIOLATION CLOSED § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... 3 Jan 16, 2017
Dec 19, 2016 B NOV SENT OUT § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE IN THE ENTIRE APARTMENT LOCAT... 3 Jan 23, 2017
Dec 19, 2016 B NOV SENT OUT § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STO... 3 Jan 23, 2017
Dec 19, 2016 B NOV SENT OUT § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE GASKETS AT REFRIGERATOR DOORS IN THE KITCHEN LOCATED AT AP... 3 Jan 23, 2017
Dec 19, 2016 B NOV SENT OUT § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE ... 3 Jan 23, 2017
Dec 19, 2016 B NOV SENT OUT § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT BOILER ROOM IN THE ENTIRE APARTMENT LOCATED AT AP... 3 Jan 23, 2017