ECB violations
1560-1566 Taylor Avenue, Bronx • Block 03925 • Lot 0025
25 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 11, 2025 | 39543525R | RESOLVE | CLASS - 2 | AT TIME OF MY INSPECTION I OBSERVED A SIDEWALK SHED AT A 6 STORY BUILDING. SIDEWALK SHED INFORMATION PANEL IS AT POIN... | $1,250 | $1,250 | Oct 17, 2025 |
| Aug 24, 2023 | 39520952J | RESOLVE | CLASS - 2 | MAINTENANCE OF SIDEWALK SHED PARAPET PANELS. AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED ERECTED WITH VALID PERMIT... | $0 | $0 | Nov 3, 2023 |
| Sep 1, 2022 | 39505875J | RESOLVE | CLASS - 2 | NOTE: AT THE TIME OF INSPECTION OBSERVED A SIDEWALK SHED AT EXP1, 4, PEDESTRIAN WALKING UNDER IT. OBSERVED IN DOB SYS... | $0 | $0 | Oct 21, 2022 |
| Sep 1, 2022 | 39505874H | RESOLVE | CLASS - 2 | NOTE: AT THE TIME OF INSPECTION OBSERVED A SIDEWALK SHED AT EXP1, 4, PEDESTRIAN WALKING UNDER IT. OBSERVED CROSS BRAC... | $2,400 | $2,400 | Mar 10, 2023 |
| Apr 1, 2021 | 37021182N | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $1,293 | Nov 4, 2022 |
| May 18, 2018 | 37011370L | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... | $1,250 | $0 | Nov 30, 2018 |
| Aug 19, 2017 | 38256853H | RESOLVE | CLASS - 2 | 45M7,67X10,40P7. SECURE GOVERNOR SHAVE ADJUSTED SCREW W/ LED SEAL. (67X)CAB PHONE NOT WORKING-REPAIR. (40P)PROVIDE AC... | $0 | $0 | Oct 6, 2017 |
| Jul 3, 2017 | 35275073L | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35173388Z ISSUED ON 2-14-17 & TO FILE A C OF C PURSUANT... | $0 | $0 | Sep 1, 2017 |
| May 10, 2017 | 35233524X | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35173388Z ISSUED ON 2-14-17 & TO FILE A C OF C PURSUANT... | $0 | $0 | Jul 3, 2017 |
| Feb 24, 2017 | 35204530J | RESOLVE | CLASS - 1 | MISCELLANEOUS VIOLATIONS.AT THE TIME OF MY INSPECTION C 1:15PM ON THE ABOVE DATE AT THE ABOVE ADDRESS I OBSERVED IN T... | $1,000 | $0 | May 5, 2017 |
| Feb 24, 2017 | 35204529M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT THE TIME OF MY INSPECTION C 1:15PM I OBSERVED IN THE CELLAR ... | $1,000 | $0 | May 5, 2017 |
| Feb 24, 2017 | 35204528K | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT.AT THE TIME OF MY INSPECTION C 115 PM I OBSERVEDIN THE CELLAR ON THE ABOVE DATE A THE ABOVE ADD... | $0 | $0 | May 5, 2017 |
| Feb 14, 2017 | 35173389K | RESOLVE | CLASS - 2 | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED # OF FAMILIES. DOB'S RECORDS INDICAT... | $0 | $0 | May 5, 2017 |
| Feb 14, 2017 | 35173388Z | RESOLVE | CLASS - 1 | WORK W/O A PERMITS. WORK NOTED: 1)AT THE 1ST FL,ERECTED FULL HEIGHT PARTITIONS TO CREATE 1 ADDITIONAL APT & INSTALLED... | $0 | $0 | May 5, 2017 |
| Nov 25, 2013 | 35037785X | RESOLVE | CLASS - 2 | FAILURE TO INSTALL GROUND FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION AS REQUIRED. APT G KITCHEN RECEPTACLE OUTLETS: ... | $1,200 | $0 | Jan 31, 2014 |
| Nov 25, 2013 | 35037786H | RESOLVE | CLASS - 1 | FAILURE TO PROPERLY BOND ELECTRICAL SYSTEMS. BSMT SERVICE EQUIPMENT: 200AMP SERVICE SWITCH NEUTRAL BAR NOT BONDED TO ... | $3,000 | $0 | Jan 31, 2014 |
| Oct 15, 2013 | 38228756H | RESOLVE | CLASS - 2 | 3M7,99BB5,68B7,70O2,60X10. 3- NO PHONE. | $530 | $0 | Feb 21, 2014 |
| Jan 25, 2010 | 34835158R | RESOLVE | CLASS - 1 | FAIL TO COMPLY W/COMM'S ORDER TO CORRECT VIO#3475503Z FOR WORK W/O PERMIT @ PARAPET.NO RECORD OF CORRECTION.REM:COMPL... | $6,000 | $0 | Sep 17, 2010 |
| Sep 1, 2009 | 34802048P | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO OBTAIN A PERMIT PER VIO # 34755503Z ISSUED 3/14/09 FOR WORK W/O PERMI... | $2,400 | $0 | Feb 5, 2010 |
| Mar 14, 2009 | 34755503Z | RESOLVE | CLASS - 1 | WORK W/O A PERMIT: AT ROOF LEVEL ERECTED NEW INTERIOR MASONRY PARAPET WALL W/COPING THROUGHOUT. REMEDY: STOP ALL WORK... | $1,600 | $0 | Jul 13, 2009 |
| Nov 7, 2008 | 38191534X | RESOLVE | CLASS - 2 | 12Q3.100I11.REPLACE OVERHEAD SKY LIGHT | $0 | $0 | Jan 2, 2009 |
| Aug 6, 2004 | 34461599Z | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHINCAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED ... | $1,750 | $0 | Feb 18, 2005 |
| Dec 26, 2003 | 34462767N | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT PERIODIC INSPECTION OR EXTERIOR WALLS AND APURTENANCES AS REQUIRED B... | $700 | $0 | Apr 23, 2004 |
| Jun 21, 2002 | 38123787J | RESOLVE | Non-Hazardous | 51L11/50Y14/52002. 51 CHECK FOR AND ELIMINATE EXESSIVE GRINDING NOISE 52 CLEAN OIL. | $0 | $0 | Aug 16, 2002 |
| Apr 7, 2000 | 38096275P | RESOLVE | Non-Hazardous | 21#11,22D6,46#2,57O2,74O2. 21- INDICATE LIGHT NOT WORKING. 22- OVERHEAD HATCH INSIDE FOR CAR UNSECURED. 46- CLEAN FLU... | $350 | $0 | Apr 9, 2001 |