Skip to content

ECB violations

3120 Wilkinson Avenue, Bronx • Block 04238 • Lot 0027

46 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jul 16, 2026 39196444L ACTIVE CLASS - 2 CLASS 2: IN-CAR COMMUNICATION IS NOT CONNECTED TO A CONTINUOUSLY STAFFED LOCATION, AS REQUIRED BY NYC BUILDING CODE A... $625 $625 Oct 2, 2026
May 22, 2026 39189732K RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSP... $1,250 $1,250 Aug 21, 2026
Apr 28, 2026 39186346Z ACTIVE CLASS - 1 UNLAWFUL ACTS - FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. AT TIME OF INSPECTION, OBSERVED AN ILLUMINATED SIGN ... $2,500 $2,500 Nov 13, 2026
Mar 31, 2026 39182619R ACTIVE CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. AT TIME OF INSPECTION NO PERMITS NO CERTIFICATE OF CORREC... $2,500 $2,500 Nov 13, 2026
Dec 10, 2025 39169965N RESOLVE CLASS - 2 UPON INSPECTION THE INSTALLATION OF A SIGN IN BROWN WITH BRONX DELI & MINI MARKET IN WHITE AND GREEN LETTERS APROX. 2... $0 $0 Jun 12, 2026
Feb 10, 2025 39137905P ACTIVE CLASS - 1 ATOI OBSERVED AN ILLUMINATED SIGN INSTALLED OVER A CORNERSPACE DELI, NO PERMITS ON FILE FOR THIS WORK. SIGN 16X3 AND ... $2,500 $2,500 Jun 13, 2025
Aug 13, 2024 39121803H ACTIVE CLASS - 1 ATOI OBSERVED COMM. SPACE 30 LED LIGHT CEILING PANELS INSTALL WITH ELECTRICAL ROMEX CABLE AND NEW ELECTRICAL PANEL. B... $800 $0 Sep 2, 2025
Aug 13, 2024 39121802X RESOLVE CLASS - 1 ATOI OBSERVED 30 LED CEILING LIGHT FIXTURES INSTALLED THROUGHOUT COMMERCIAL SPACE, POWERED BY ELECTRICAL ROMEX CABLES... $0 $0 Sep 2, 2025
Dec 12, 2023 39101254X RESOLVE CLASS - 2 SUMMONS ISSUED FOR FAILURE TO MAINTAIN DUE TO EXTERIOR BRICK/WOOD MISSING AT FIRST FLOOR COMMERCIAL SPACE ENTRANCE AR... $625 $625 Dec 13, 2024
Jul 14, 2023 39090258M RESOLVE CLASS - 2 NOTED AT TIME OF INSPECTION I OBSERVED A EXPOSURE #1 STORE FRONT A ILLUMINATED BUSINESS ACCESSORIES SIGN WRAP AROUND ... $1,250 $630 Sep 29, 2023
Apr 28, 2021 35536956H RESOLVE CLASS - 1 WORK W/O PERMIT OBSERVED@5A 3120WILKINSONAVE BRONXNY ELECTRICAL WORK DONE W/O PERMIT.NEW BRAKERBOX RAN THRUOUT APT.NE... $0 $0 Oct 1, 2021
Mar 4, 2020 39018991Z RESOLVE CLASS - 1 CLASS 1, 2 ITEMS, NO DOOR LOCK MONITORING IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC.... $1,250 $1,250 Oct 1, 2021
Jun 12, 2018 38262020Y RESOLVE CLASS - 2 37X11,69M7,68B7,59BB15. LIGHTING IN OVERHEAD WHEELHOUSE IS INOPERATIVETHERE IS NO CODE DATA PLATE IN MACHINE ROOM, NO... $0 $0 Aug 3, 2018
May 17, 2018 35331002H RESOLVE CLASS - 1 REISSUE #35248764R FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTE: AT EXP#1&2 BOWING & DEFECTIVE LINTELS AT EX... $0 $0 Nov 9, 2018
Mar 28, 2018 35248764R RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES.AT TIME OF INSPECTION THE VIOLATING CONDITIONS ARE AS FOLLOWS(1)... $625 $0 Jul 13, 2018
Jun 5, 2017 38255420H RESOLVE CLASS - 1 CEASE USE. 5M7. MISSING DOOR ZONE RESTRICTOR. THIS IS A SAFETY DEVICE TO ENSURE ELEVATION PASSENGERS SAFETY PROVIDE R... $1,000 $0 Aug 4, 2017
Feb 15, 2017 35204392K RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. AT TIME OF MY INSPECTION AT 4:35PM ON ABOVE ADDRESS I OBSERVED IN ... $0 $0 Apr 7, 2017
Oct 12, 2016 38250234L RESOLVE CLASS - 2 5J1,10H11,29J10,16J10,59M7,56Y2,56Y13,77K10. CAR DOOR MISALIGNED ADJUST, CAR DOOR GIBS WORN REPLACE. DOOR OPERATOR MI... $0 $0 Dec 2, 2016
Sep 26, 2016 38245137N RESOLVE CLASS - 2 52B14,59U15,70O02. (52)HOIST ROPES(B)INSUFFICIENT(14)SHORTEN. (59)MACHINE BRAKE(U)DEVICE NOT TAGGED(15)TAG DEVICE. (7... $250 $0 Nov 18, 2016
Mar 16, 2016 35168991R RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED @ EXP1 NORTH WEST COURT ONE BRICK MISSING @ BOTTOM OF WALL @ ... $250 $0 Jun 10, 2016
May 15, 2014 35066473J RESOLVE CLASS - 1 WORK W/O A PERMIT. ON 5/15/14 @ 4:00PM DURING PHYSCIAL INSPEC. I OBSERVED 1 NEW METER BAR NEW GAS & NEW WASTE P1PING ... $0 $0 Oct 10, 2014
May 15, 2014 35066474L RESOLVE CLASS - 1 GAS BEING SUPPLIED TO BLDG W/O INSPEC.& CERTIFICATION BY DOB.ON 5/15/14 @4:00PM DURING PHYSCIAL INSPEC.I OBSERVED 1 N... $2,500 $0 Oct 10, 2014
Apr 18, 2014 35066407L RESOLVE CLASS - 1 GAS BEING SUPPLIED TO BLDG W/O INSPECTION/CERTIFICATION BY DOB.DURING PHYSICAL INSP 1 OBSERVED 2 ADC DRYERS IN USE W/... $1,000 $0 Aug 15, 2014
Apr 18, 2014 35066406J RESOLVE CLASS - 1 FAILURE TO HAVE NEW OR ALT PLUMB SYSTEM TESTED.DURING PHYSICAL INSP I OBSERVED 2 ADC DRYERS & RELATED GAS LINES IN US... $1,000 $0 Aug 15, 2014
Apr 18, 2014 35066405H RESOLVE CLASS - 1 WORK W/O A PERMIT DURING PHYSICAL INSP I OBSERVED IN THE CELLAR LAUNDRY ROOM 2 DRYERS & 1 WASHER & RELATED PIPING INS... $1,600 $0 Aug 15, 2014
Aug 23, 2012 38223048Y RESOLVE CLASS - 2 37T07,37Q03,67M07,69M07,77B11: 37T07;PROVIDE SIGN FOR OVERHEAD SHEAVE ROOM DOOR. 37Q03;INSTALL GUARD FOR LIGHT IN OVE... $0 $0 Oct 19, 2012
Sep 21, 2009 38205497K RESOLVE CLASS - 2 98BB5.14M7.68M9.69M9.9H10.98BB5.52H14 $0 $0 Nov 6, 2009
Aug 20, 2009 38204146Y RESOLVE CLASS - 2 5S4.16H11.100X10.16H11 TOP PIVOT 5TH FL 42FL 42B10 ELEVATOR ISN'T LIFTING FULL CAPACITY 52M7 SPIN OUTS 77Q3 WIRES UND... $250 $0 Dec 7, 2009
Sep 10, 2008 32060579L RESOLVE CLASS - 3 301.1 B354 50A. 50A SAIL SW ON FRESH AIR FAN DEFECTED $0 $0 Nov 7, 2008
Jul 23, 2008 32060161Y RESOLVE CLASS - 3 354,15,40,42,48A,50,50A,B,C,D.50-MUST SEAL AROUND SMOKE PIPE.50A-DEBRIS IN BOILER ROOM.50B-BUCKETS OF OIL IN BOILER R... $100 $0 Sep 19, 2008
Sep 21, 2007 38168961P RESOLVE Non-Hazardous 5B10/21Q3/85BB5/3L10/.5-FAST SPEED DOOR CAN'T COVER VISION PANEL.PROVIDE SEEING ACCESS TO HALL DOORS.3-REPAIR WALL BY... $0 $0 Nov 16, 2007
Dec 27, 2002 38134582J RESOLVE Non-Hazardous 81U05 - DATE OF TAG 112497. $0 $0 May 23, 2003
Aug 20, 2002 38124736Y RESOLVE Non-Hazardous CEASE USE/ 40R05/ 23U07/ 47B15/ 46K11/ 75#05/ 40 GOV INSTALLED W/O PERMIT CEASE USE UNITL ITEM # 40 TESTED BY THIS DE... $440 $0 Nov 1, 2002
Jul 22, 2002 38123897K RESOLVE Hazardous CEASE USE 40R05/ 75#05/ 33R09/ 40U07/ 03O02/ 23U07/ 47B15/ 35P07/ 74M07/ 40 - CEASE USE GOV NOT TESTED BY THIS DEPT R... $440 $0 Nov 1, 2002
Jun 12, 2002 38122771K RESOLVE Non-Hazardous 57O02/14M7/74M7/18M7/30O2/4K12/58O02/59O02/9H12/25B1. 18 INERLOOK COVER MISSING 4TH FL PROVIDE. 74 PROVIDE CAPACITY M... $0 $0 Jul 26, 2002
May 22, 2002 38122717J RESOLVE Non-Hazardous CEASE USE 14M07/ 47B15/ 40U07/ 22U07/ 75#05/ 33R09/ 03O02/ 40R#/ 14 POST CERT AS PER 27-1004A OR 27-1004B, 33 REMOVE ... $350 $0 Aug 2, 2002
Apr 16, 2002 32033812P RESOLVE Non-Hazardous 34A, 49A, 49B, 49C, 49D. 49A)NO CHECK VALVE (BACK FLOW PREVENTER) ON BOILER FEED LINE. 49B) NO RELIEF ON COLD WATER S... $350 $0 Aug 2, 2002
Feb 16, 2002 38121424L RESOLVE Non-Hazardous 075U05/17Q07/18Q03/73O02/14M07/74M07/18D06/74I11. 17 VISION PANEL GRIK ON 4. 18 BASEMENT. 74 CAPACITY PLATE. 18D6 LOB... $0 $0 Apr 5, 2002
Mar 21, 2001 38114945L RESOLVE Non-Hazardous 75U05/57Z09/15X11/10X11/18L11/18Q03/14M07/57-2-09 REMOVED WATER FROM PIT 15-2ND FL H/DOOR 10X11-2ND FLOOR HALL AND CA... $0 $0 May 4, 2001
Nov 20, 2000 38109718P RESOLVE Non-Hazardous 75U05, 03B11. 03-REPAIR HOLES IN CAB (AIR VENT AREAS) BOTH SIDES. $0 $0 Jan 12, 2001
Mar 4, 1999 38085146P RESOLVE Non-Hazardous 5A12,15L1,3M7. -5 VISION PANEL MUST BE WIRE GLASS, -15 ADJUST FOR PRO-PER CLOSING, -3 CAPACITY PLATE $0 $0 Apr 23, 1999
Sep 2, 1997 38062982Z RESOLVE Non-Hazardous 75U5,14M12,57O2. $0 $0 Dec 26, 1997
Aug 29, 1994 38043531X RESOLVE Non-Hazardous 2X,35P,46B,74O,57O, $250 $0 Dec 2, 1994
Jun 11, 1993 38034220Y RESOLVE Hazardous 01M,CEASE USE OF ELEVATOR UNTILL ITEM#01 IS COMPLIED WITH, BEFORE RETURNING ELEVATOR TO SERVICE CALL 312 8735 FOR REI... $500 $0 Aug 13, 1993
Mar 1, 1991 38005676J RESOLVE Non-Hazardous 14M,17M,50B,25M,(17)PROVIDE MISSING VISION PANEL GUARDS WHERE NECESSARY (50)REMOVE NOISE FROM MAIN MACHINE (25)REPLAC... $0 $0 Aug 2, 1991
Mar 1, 1990 34029444L RESOLVE Non-Hazardous WORK WITHOUT A PERMIT. REMEDY: OBTAIN A PERMIT. $250 $0 May 11, 1990