| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Sep 28, 2020 | 37020248M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VI OLATION#39009342Y ISSUED ON 9/11/2019,AND TO FILE... | $3,125 | $3,125 | Dec 18, 2020 |
| Feb 11, 2020 | 37017540M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #38269500P ISSUED ON 04-29-2019,AND TO FILE... | $3,125 | $3,125 | Nov 13, 2020 |
| Feb 11, 2020 | 39017297Y | ACTIVE | CLASS - 1 | CEASE USE/ CAR DOOR RESTRICTOR ALTERED, REPAIR AND CONTACT NYCDOB RE INSPECTION FOR RESTORE TO SERVICE , CLASS 1/ NO ... | $1,280 | $0 | Jan 22, 2021 |
| Sep 11, 2019 | 39009342Y | RESOLVE | CLASS - 2 | REPLACE WORN HOISTWAY DOOR GIBS WHERE NEEDED. SECURE HOISTWAY DOOR GIBS WHERE NEEDED. MISSING PIT LADDER. PROVIDE IN ... | $625 | $0 | Nov 1, 2019 |
| Apr 29, 2019 | 38269500P | RESOLVE | CLASS - 2 | 56.Y.13,53.U.07,52.U.07,26.D.06,39.O.02,59.B.07;(56)SEAL HOIST MACHINE(53)PROVIDE GOV ROPE DATA TAG (52)PROVIDE HOIST... | $625 | $0 | Jun 21, 2019 |
| Sep 26, 2016 | 38245136L | RESOLVE | CLASS - 2 | 32H10,70O02. (32H10)GUIDE SHOES WORN REPAIR. (70002)PIT DIRTY CLEAN. | $0 | $0 | Nov 18, 2016 |
| Aug 5, 2016 | 38244696P | RESOLVE | CLASS - 1 | 05A10 CAB DOOR RESTRICTOR IS BEEN TAMPERED WITH (REPAIR) | $0 | $0 | Dec 16, 2016 |
| Aug 5, 2016 | 38244695N | RESOLVE | CLASS - 1 | 05A10,59D06,68B07,70O02,71L10 (05-A-10) CAB DOOR RESTRICTOR HAS BEEN TAMPERED WITH (REPAIR) | $1,000 | $0 | Oct 28, 2016 |
| Jan 28, 2016 | 38240520N | RESOLVE | CLASS - 1 | 03E10,05M07,08V01,59M05,59O02,56Y10. 03-CAR RUBBING ONTO SHAFTWAY REP AIR; 05-CAR DOOR ZONE RESTRICTOR MISSING MUST P... | $1,000 | $0 | Apr 8, 2016 |
| Dec 17, 2015 | 38239118R | RESOLVE | CLASS - 1 | 97V01,07O02,70O02. 97V01-DEVICE NOT LEVEL ON EVERY FLOOR 1-2".TRIPPINGHAZARD; 97O02-DIRTY SHAFTWAY.CLEAN; 70O02-DIRTY... | $1,000 | $0 | Feb 5, 2016 |
| Mar 29, 2010 | 38209805L | RESOLVE | CLASS - 2 | 8V1/ 17H11/ 40P16/ 100I10/ 17-H-11 - 6 FLOOR DOOR GIBS 100-I-10 - CAR FAN | $0 | $0 | May 21, 2010 |
| Jul 16, 2005 | 34465766P | ACTIVE | Non-Hazardous | FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED.NO SPRINKLERS OVER DRYERS IN LAUNDRY ROOM.REMEDY:P... | $200 | $0 | Sep 2, 2005 |
| Jul 16, 2005 | 34465767R | ACTIVE | Non-Hazardous | INSTALLATION OF PLUMBING MATERIALSWHICH DO NOT COMPLY WITH RS-16 RAN FLEX CONNECTORS TO DRYERS IN LAUNDRY ROOM.MUST B... | $200 | $0 | Sep 2, 2005 |